System 5600 - 1

©BOK CENTER System 5600 2 1/2" Curtain Wall Thermally Improved System CONFIGURATIONS Outside Glazed • 2 or 4-sided Structural Glazed EFCO 2 1/2" system 5600 provides a monumental sight line and is available in a wide range of mullion and face cover depths. The 2 1/2" 5600 pressure wall has roll-on horizontals and concealed fasteners for a smooth uninterrupted joinery. Also Available for enhanced thermal performance and fewer installation steps is the Duracast® pressure plate, made of Pella's patented fiberglass pultrusion. Thermal Isolator used between exterior and Improved thermal performance interior extrusions Various mullion depths Provides design flexibility Wide variety of snap-on face covers Customize projects with face covers of various depths and profiles Optional corner mullions Allows 90° inside and outside corners Concealed shear block construction Ability to erect on the job site Concealed vents Ability to include ventilation while maintaining the exterior sight line Integral door adaptors Compatible with all 1 3/4" and 2" EFCO entrances Accommodates up to 1 1/4" glazing Expands design and energy saving options Accessory line of perimeter anchors, pocket fillers, Increased product versatility door adaptors, etc. Anodized and painted finishes available Multiple options to answer economic and aesthetic concerns Roll-On Horizontals Concealed fasteners, reduced installation labor © Copyright 2015 EFCO Corporation 05/16 1000 COUNTY RD • MONETT, MO 65708 • 800.221.4169 • efcocorp.com

Open the catalog to page 1
System 5600 - 2

System 5600 2 1/2" Curtain Wall Thermally Improved System PERFORMANCE DATA SERIES 5600 OUTSIDE GLAZED CURTAIN WALL SERIES 5600 CONCEALED VENT AIR INFILTRATION <.06 CFM/SF @ 6.24 PSF AIR INFILTRATION <30 CFM/SF @ 6.24 PSF Note: All performance value data is based on laboratory testing per A AM A101/I.S.2/A440 for Air/Water/Structural, ASTM E90 and or E413 for Acoustical, AAMA507 and or NFRC 100/200/500 for UFactors and AAMA 1503 for Condensation Resistance Factor (CRF). Printed values are subject to change pending the frequency of recertification testing. Field results will vary...

Open the catalog to page 2
System 5600 - 3

System 5600 2 1⁄2” Curtain Wall Thermally Improved System Main Frame Construction System 5600 curtain wall has various system depths. Sight lines are nominally 2 1/2” and present a clean, attractive appearance. Members are extruded from 6063-T6 aluminum alloy, and the nominal material wall thickness is .093” to .125”. Joint construction utilizes the shear block method. See Illustration 1. Concealed Vent Construction System 5600 curtain wall has optional concealed vents that utilize screw spline construction. Thermal Barrier System 5600 curtain wall members are thermally improved using vinyl...

Open the catalog to page 3

All EFCO catalogs and technical brochures

  1. Series 3000

    3 Pages

  2. Series 5XPT

    3 Pages

  3. 875X

    3 Pages

  4. 5600PG

    3 Pages

  5. Series 6621

    2 Pages

  6. Series CS32

    3 Pages

  7. Series 511

    2 Pages

  8. Series 510

    3 Pages

  9. Series 2700

    3 Pages

  10. Series 2701

    2 Pages

  11. Series 2901

    3 Pages

  12. Series 2600

    3 Pages

Archived catalogs

  1. SHADOW LINE

    5 Pages