yf EDI LTECO* Thermal ^ ^ g r o u p insulation 8c chemical AZINDA CON SISTEMA DI GESTIONE PERLA QUALITˀ CERTIFICATO DA DNV =11 NI EN ISO 9001:2000 = PROTHERM LIGHT Lightweight plaster for fire protection lightweight premixed thermal insulating plaster for fire protection (REI) of masonry product: structure, reinforced concrete, concrete and steel structures. Packaging and storage: Bag of 16 kg Օ Pallet (protected by thermo-wrapping film): n° 40 bags = 720 kg Store in a dry place and use by 6 months. Composition: Colours: based of virgin EPS beads, water bindings and special additives. To mix with water during the application. Օ Protherm Light B: white ivory Protherm Light G: grey Fields of application: Fireproofing protective system, specific to improve fire resistance of structural elements made of steel, brick, normal and pre-stressed reinforced concrete, in building for civil and industrial utilization. Mechanical and manual application. For indoor and outdoor use. Omologations and Certifications: Are available certificates for fire resistance, which are executed either according to the Circular n.91 (valid again for the period indicated by D.M. 16 March 2007), and also according also to the most recent European standard. The Professionals - who must draw up the "Estimative report about fire resistance of structural or partitional constructive elements" to attach together with the demand for request or for renovate of CPI (Certification of Fire Prevention), according with the modalities by D.M. 10 March 1998 - to calculate the thickness and quantity of protective material to apply, according to the type of element to protect and the required fire resistance, he can be also use the analytic method or chart, in reference to one of these followings technical criterion: Օ Norm UNI 9502 "Analytic procdure to estimate fire resistance of constructive elements of reinforced, normal and pre-stressed concrete". Norm UNI 9503 "Analytic procedure to estimate fire resistance of constructive steel elements". 镕 Circular n. 91 of the Ministry of the Interior "Safety norms for fire protection of building with a steel structure and which are destined to civil use", limitedly to already existent buildings and according to the paragraph 4. article 4 of D.M. 9 March 2007. ~ 3,0 kg/m2 per 1 cm of thickness. With one bag ~ 6 m2 per 1 cm of thickness. Application on concrete, reinforced concrete or masonry: clean the support to be protected; in case of surfaces with old plastering, we suggest to make pressure hydro-washing or with a strong mechanical brushing, then make a deep cleaning of support to eliminate completely all the layer of incoherent material. We recommend to wash accurately the support removing completely each trace of incoherent material. Application on steel: clean the support to protect; in case of surfaces with old varnish layers, we suggest to made pressure hydro-washing or with a strong mechanical brushing, then make a deep cleaning of support to eliminate completely all the layer of incoherent material. After sanding or strong mechanical brushing, we recommend to use an anti-corrosive base, (there are no technical and qualitative limits). Important: in case the steel elements to be treated would have been strongly warmed by sunlight or by any other Consumption / yield: Support preparation: '^EDILTECO L. J g r o u p EDILTECO S.p.A. - Via delilndustria, 710 - 41038 S.Felice sul Panaro (MO) - Italy m +39 0535 82161 - fax +39 0535 82970 - M info@edilteco.it www.edilteco.it ProthermLight_2010-04-20_ING - Pagina 1 di 2

Open the catalog to page 1
Protherm Light - 2

yf EDI LTECO* Thermal ^ ^ g r o u p insulation & chemical follows Support prparation: causes, before apply Protherm Light the surfaces must be cooled using clean water (and then dry) or it would be necessary to wait the natural cooling of surfaces. Important: before the application or fireproofing coating, the applicator must always check if the support to protect needs of a primer, controlling the efficiency with preliminary application tests. In case of doubt or cases not specifically mentioned: consult our Technical Service. Application: Mechanical application, using a sprayer, with...

Open the catalog to page 2

All Edilteco catalogs and technical brochures

  1. F6-C

    1 Pages

  2. F4-C

    1 Pages

  3. F10

    1 Pages

  4. F8

    1 Pages

  5. F5

    1 Pages

  6. dry-holz

    2 Pages

  7. ECAP® L 100

    2 Pages

  8. ISOLSAN

    2 Pages

  9. ISOLTECO

    2 Pages

Archived catalogs

  1. dBRED F3-B

    1 Pages

  2. FONOTECH

    2 Pages