Ecophon Master Rigid A
6Pages

{{requestButtons}}

Catalog excerpts

Ecophon Master Rigid A - 1

10-70-1202 , A digiR ™retsaM nohpocE .rgaiD .tsnI ssenkcihT 42T EGNAR METSYS modgniK detinU ,telsnuH tseW ,loohcS yelweB . deveihca era s ci t suoca lami t po , s sa B ar t x E n o h p o cE h t i w r e h te g o t d e s U . n o i t c u r t s n o c h c i w d n a s d e c r of n i e r a s i e c af r u s e h T .e l b a t n u o m e d y l l uf s i d n a s p i l c y b d i r g e h t n i d e r u c e s s i e l i t h c aE . m e t s y s d i r g d e s o p xe n a sa h A d i g i R ™ r e t sa M n o h p o cE

Open the catalog to page 1
Ecophon Master Rigid A - 2

Sound Absorption: Test results according to EN ISO 354. Classification according to EN ISO 1 1654. • • • • Master Rigid A 20 mm, 50 mm o.d.s. — Master Rigid A 20 mm, 200 mm o.d.s. — Master Rigid A 20 mm + Extra Bass 50 mm, 200 mm o.d.s. • • • • Master Rigid A 20 mm + 2xExtra Bass 100 mm, 200 mm o.d.s. — Master Rigid A gamma 20 mm, 200 mm o.d.s. Frequency Hz Certificate / Label Emissions dans lair intErieuit mi>] © Ecophon Group Ecophon Master™ Rigid A, 2021-07

Open the catalog to page 2
Ecophon Master Rigid A - 3

Circularity 46% Fully recyclabl Minimum post-consumer recycled content Recyclability Country Standard Class The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1 182. White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance. Gloss < 1. Cleanability Daily dusting and vacuum cleaning. Weekly wet wiping. The tiles are secured in the grid, but demountable. Minimum demounting depth according to installation diagrams. Installation Installed according to installation diagrams, installation guides and drawing aid. For information regarding...

Open the catalog to page 3
Ecophon Master Rigid A - 4

10-70-1202 , A digiR ™retsaM nohpocE .tekram naeporuE eht no elbaliava stcudorp fo ecnamrof rep erapmoc ylisae ot sresu dna sremotsuc selbane hcihw )POD( ecnamrof reP fo noitaralceD a yb derevoc era stcudorp noitcurtsnoc dekram EC .4102:46931NE dradnats dezinomrah naeporuE eht ot gnidrocca dekram EC era smetsys gniliec nohpocE EC .D xenna 46931 NE ot gnidrocca defiissalc dna detseT

Open the catalog to page 4
Ecophon Master Rigid A - 5

INSTALLATION DIAGRAM (M316EB) FOR ECOPHON MASTER RIGID A ©Ecophon Group QUANTITY SPECIFICATION (EXCL. WASTAGE) Size, mm 1200x600 2 Connect T24 Main runner, installed at 1200 mm centres (max. distance from wall 600 mm, can be extended up to 1200 mm if no live load between Main 0,9m/m2 runner and wall). 3 Connect T24 Cross tee, L= 1200 mm, installed at 600 mm centres 1,7m/m2 5 Connect Adjustable Hanger, installed at 1200 mm centres (max. distance from wall 600 mm] 0,7/m2 6 Connect Hanger Clip (not to be used in swimming hall environments) 0,7/m2 7 Connect Hold down dip A 2pcs/panel 8 Connect...

Open the catalog to page 5
Ecophon Master Rigid A - 6

INSTALLATION DIAGRAM (M333) FOR ECOPHON MASTER RIGID A XL IN CORRIDORS M333 © Ecophon Group QUANTITY SPECIFICATION (EXCL. WASTAGE) Size, mm 2 Connect Angle trim, fixed at 200 mm centres 3 Connect T24 Corridor profile, installed at 600 mm centres 4 Connect Wall bracket for T-profiies 5 Connect Hygiene clip 20 0172 6 Connect Angle trim as required as required as required as required 2 for every row of corridor profile 3,15/m2 (3/tile) 2,8/m2 (3/tile) 2,5/m2 (3/tile) 2,1/m2 (3/tile) as required as required as required as required A Min. overall depth of system: 150 mm © Ecophon Group Ecophon...

Open the catalog to page 6