Ecophon Focus E
7Pages

{{requestButtons}}

Catalog excerpts

Ecophon Focus E - 1

© Ecophon Group Ecophon Focus™ E, 2021-07-01

Open the catalog to page 1
Ecophon Focus E - 2

Acoustic Sound Absorption: Test results according to EN ISO 354. Classification according to EN ISO 11654, and the single value ratings for Noise Reduction Coefficient, NRC and Sound Absorption Average, SAA according to ASTM C 423. AC(1.5) Articulation Class, ASTM El 1 11, ASTM El 1 10 unfw Weighted normalized flanking level difference, ISO 10848-2 CACdB Ceiling Attenuation Class, ASTM 1414, ASTM E413 Indoor Air Quality Certificate / Label Emissions dans l-air intEhieur* © Ecophon Group Ecophon Focus™ E, 2021-07-01

Open the catalog to page 2
Ecophon Focus E - 3

White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance. Gloss < 1. Cleanability Daily dusting and vacuum cleaning. Weekly wet wiping. The tiles are easily demountable. Minimum demounting depth according to installation diagrams. Installation Installed according to installation diagrams, installation guides and drawing aid. For information regarding minimum overall depth of system see quantity specification. System weight The weight of the system (including suspension grid] should be approximately 3 kg/m2. Mechanical properties See table about Max live load and Min load...

Open the catalog to page 3
Ecophon Focus E - 4

.tekram naeporuE eht no elbaliava stcudorp fo ecnamrof rep erapmoc ylisae ot sresu dna sremotsuc selbane hcihw )POD( ecnamrof reP fo noitaralceD a yb derevoc era stcudorp noitcurtsnoc dekram EC .4102:46931NE dradnats dezinomrah naeporuE eht ot gnidrocca dekram EC era smetsys gniliec nohpocE

Open the catalog to page 4
Ecophon Focus E - 5

INSTALLATION DIAGRAM (Ml2) FOR ECOPHON FOCUS E M12 © Ecophon Group QUANTITY SPECIFICATION (EXCL. WASTAGE) Size, mm 2 Connect T24 or T15 Main runner, installed at 1 200 mm centres (max. distance from wall 600 mm, can be extended up to 1200 mm if no 0,9m/m2 live load between Main runner and wall). 3 Connect T24 or T15 Cross tee, L=1200 mm 1,7m/m2 5 Connect Adjustable Hanger, installed at 1200 mm centres (max. distance from wall 600 mm] 0,7/m2 6 Connect Hanger Clip (not to be used in swimming hall environments] 0,7/m2 7 For direct installation: Connect Direct Bracket, installed at 1200 mm...

Open the catalog to page 5
Ecophon Focus E - 6

2 Connect T24 Main runner, installed at 600 mm centres 4 Connect Adjustable hanger, installed at 1500 mm centres (max. distance from wall 450 mm) 5 Connect Hanger clip 6 Connect Angle trim, fixed at 300 mm centres 7 Connect Shadow-line trim, fixed at 300 mm centres 8 Connect E-plug (for Shadow-line trim] as required as required as required as required as required as required as required as required as required as required as required as required A Min. overall depth of system: 1 10 mm 8 Minimum demounting depth: 1 10 mm Size, mm Max live Min load bearing bad (N) capacity (N) 1600x600 50 160...

Open the catalog to page 6
Ecophon Focus E - 7

INSTALLATION DIAGRAM (M49) FOR ECOPHON FOCUS E XL IN CORRIDORS M49 ©Ecophon Group QUANTITY SPECIFICATION (EXCL. WASTAGE) Size, mm 2 Connect T24 Corridor profile, installed at 600 mm centres 3 Connect Angle trim, fixed at 200 mm centres 4 Connect Shadow-line trim, fixed at 200 mm centres 5 Connect E-plug (for Shadow-line trim] as required as required as required as required as required as required as required as required as required as required as required as required A Min. overall depth of system: 50 mm © Ecophon Group Ecophon Focus™ E, 2021-07-01

Open the catalog to page 7