Overview: This document provides R-values for various Eco Insulation products used in different construction scenarios, including roofs and walls. R-values indicate the thermal resistance of insulation materials, which is crucial for energy efficiency in buildings.
1. Skillion Roof – Profiled Metal Cladding:
  • Insulation involves ceiling dwangs with 10 mm plasterboard.
  • Options include blanket/segment insulation with different rafter and dwang dimensions.
  • A 25 mm clearance is required between insulation and membrane.
2. Flat Timber-Framed Membrane Roof:
  • Utilizes ceiling battens with 10 mm plasterboard.
  • Insulation options vary by rafter size and batten spacing.
  • Adding 0.2 to the R-value is recommended for blanket insulation.
3. Pitched Timber-Framed Roof – Concrete or Clay Tile:
  • Features flat ceiling with battens and 10 mm plasterboard lining.
  • Insulation options include timber or metal battens with specified spacing.
  • Additional 0.2 R-value for blanket insulation over joists.
4. Pitched Timber-Framed Roof – Profiled Steel Cladding:
  • Includes flat ceiling with joists and plasterboard lining.
  • Insulation options are specified for joist and dwang dimensions.
  • Additional 0.2 R-value for blanket insulation over joists.
5. Wall Insulation Types:
  • Bevel-back Weatherboard on Battens: Uses 100 mm framing and 10 mm plasterboard lining with various dwang and stud configurations.
  • Sheet Cladding: Similar framing and lining with specified dwang and stud spacing.
  • Rusticated or Shiplap Weatherboard: Options for battens and cladding with different framing and lining setups.
  • Brick/Block Veneer: Utilizes 100 mm framing and plasterboard lining with specified dwang and stud spacing.
  • Masonry Block Walls: Features timber strapping and plasterboard lining with different strapping dimensions and spacing.
Conclusion: The document outlines specific insulation configurations and R-values for various construction types, emphasizing the importance of proper insulation for energy efficiency.
See more

Catalog excerpts

ecoinsulation The natural choice Wool Insulation-1

The natural choice Wool Insulation Construction R-values for specific Eco Insulation products Skillion roof – profiled metal cladding 2 Flat timber-framed membrane roof 3 Pitched timber-framed roof – concrete or clay tile 4 Pitched timber-framed roof – profiled steel cladding 5 Bevel-back weatherboard on battens 6 Sheet cladding 7 Rusticated or shiplap weatherboard on battens 8 Rusticated or shiplap weatherboard cladding 9 Bevel-back weatherboard on battens Brick/block veneer 11 Masonry block walls www.ecoinsulation.co.nz 10 12

 Open the catalog to page 1
ecoinsulation The natural choice Wool Insulation-2

Skillion roof – profiled metal cladding Required ceiling R-value ceiling dwangs with 10 mm plasterboard Insulating material R-value Key: blanket/segment insulation, 150 x 50 mm rafters 900 mm, 75 x 50 mm dwangs 900 mm blanket/segment insulation, 200 x 75 mm rafters 900 mm, 75 x 50 mm dwangs 900 mm 25 mm clearance between insulation and membrane Note: 25 mm clearance required between insulation and membrane 2

 Open the catalog to page 2
ecoinsulation The natural choice Wool Insulation-3

Flat timber-framed membrane roof Required ceiling R-value ceiling battens with 10 mm plasterboard Insulating material R-value Key: blanket/segment insulation, 150 x 50 mm rafters 900 mm, battens < 600 mm blanket/segment insulation, 200 x 50 mm rafters 900 mm, battens < 600 mm Note: Blanket insulation of equivalent R-value add 0.2 3

 Open the catalog to page 3
ecoinsulation The natural choice Wool Insulation-4

Actual ceiling R-value Pitched timber-framed roof – concrete or clay tile flat ceiling with battens and 10 mm plasterboard lining Insulating material R-value Key: blanket/segment insulation, timber battens 450 mm or 650 mm blanket/segment insulation, metal battens 450 mm Note: Blanket insulation over joists of equivalent R-value add 0.2 4

 Open the catalog to page 4
ecoinsulation The natural choice Wool Insulation-5

Required ceiling R-value Pitched timber-framed roof – profiled steel cladding flat ceiling, 150 x 50 mm joists and 10 mm plasterboard lining Insulating material R-value Key: blanket/segment insulation, joists 480 mm, dwangs 900 mm blanket/segment insulation, joists 480 mm, dwangs 900 mm Note: Blanket insulation over joists of equivalent R-value add 0.2 5

 Open the catalog to page 5
ecoinsulation The natural choice Wool Insulation-6

Bevel-back weatherboard on battens Actual wall R-value 100 mm framing and 10 mm plasterboard lining Insulating material R-value Key: dwangs 800 mm, studs 400 mm dwangs 600 mm, studs 400 mm 6 dwangs 600 mm, studs 600 mm dwangs 800 mm, studs 600 mm

 Open the catalog to page 6
ecoinsulation The natural choice Wool Insulation-7

Sheet cladding Actual wall R-value 100 mm framing and 10 mm plasterboard lining Insulating material R-value Key: dwangs 600 mm, studs 600 mm dwangs 800 mm, studs 600 mm 7

 Open the catalog to page 7
ecoinsulation The natural choice Wool Insulation-8

Required wall R-value Rusticated or shiplap weatherboard on battens 100 mm framing and 10 mm plasterboard lining Insulating material R-value Key: dwangs 800 mm, studs 400 mm dwangs 600 mm, studs 400 mm 8 dwangs 600 mm, studs 600 mm dwangs 800 mm, studs 600 mm

 Open the catalog to page 8
ecoinsulation The natural choice Wool Insulation-9

Required wall R-value Rusticated or shiplap weatherboard 100 mm framing and 10 mm plasterboard lining cladding Insulating material R-value Key: dwangs 600 mm, studs 450 mm dwangs 600 mm, studs 600 mm dwangs 800 mm, studs 450 mm dwangs 800 mm, studs 600 mm 9

 Open the catalog to page 9
ecoinsulation The natural choice Wool Insulation-10

Bevel-back weatherboard on battens Actual wall R-value 100 mm framing and 10 mm plasterboard lining Insulating material R-value Key: dwangs 800 mm, studs 400 mm dwangs 600 mm, studs 400 mm 10 dwangs 600 mm, studs 600 mm dwangs 800 mm, studs 600 mm

 Open the catalog to page 10
ecoinsulation The natural choice Wool Insulation-11

Brick/block veneer Actual wall R-value 100 mm framing and 10 mm plasterboard lining Insulating material R-value Key: dwangs 600 mm, studs 400 mm dwangs 600 mm, studs 600 mm dwangs 800 mm, studs 400 mm dwangs 800 mm, studs 600 mm 11

 Open the catalog to page 11
ecoinsulation The natural choice Wool Insulation-12

Masonry block walls Actual wall R-value Timber strapping and 10 mm plasterboard lining Insulating material R-value Key: 50 x 25 strapping, 400 mm crs 50 x 50 strapping, 400 mm crs 12 50 x 25 strapping, 600 mm crs 50 x 50 strapping, 600 mm crs Printed: August 2007

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.