Humidity and Temperature Room Sensors EE10 is dedicated for accurate relative humidity (RH) and temperature (T) measurement in residential and commercial HVAC. The RH and T measured data is available either on two analogue outputs, or on a BACnet or Modbus RTU interface. The measured data corresponding to the active outputs can be read locally on the optional display. Additional physical quantities are available on the Modbus RTU and BACnet MS/TP interface: absolute humidity, mixing ratio, enthalpy, frost point temperature and water vapor partial pressure. The stylish enclosure is available in two sizes according to regional standards. The back cover, which contains only the screw terminals, can be mounted and wired first. The front cover containing the electronics can be simply snapped onto the back cover right before commissioning. Thus the active part of the device is not exposed to construction site pollution and can be replaced without tools within seconds. Typical Applications Building automation Indoor climate control High accuracy and long term stability Fast and easy installation Modbus, BACnet or analogue outputs Technical Data Measured values Relative Humidity Working range Accuracy1) at 20 °C (68 °F) and UV=24 V DC Analogue (0 - 10 V, 4 - 20 mA) Digital (RS485) Temperature dependence, typ. Analogue (RH: 0...100 % RH / T: see ordering guide) Digital Interface Protocol 0 - 10 V -1 mA < IL < 1 mA 4 - 20 mA (2-wire) RL < (UV - 10) / 0.02 < 500 Ω RS485 with max. 32 devices on one bus Modbus RTU or BACnet MS/TP Voltage supply (UV), class III 0 - 10 V 4 - 20 mA RS485 Current consumption, typ. Analogue (0 - 10 V, 4 - 20 mA) Digital (RS485) Electrical connection Enclosure (polycarbonate) Protection rating Display Electromagnetic compatibility Temperature working range Temperature storage range 15 - 40 V DC2) or 24 V AC ±20 % 10 + 0.02 x RL < UV < 28 V DC (RL < 500 Ω) 15 - 35 V DC2) or 24 V AC ±20 % DC supply: 4 mA / AC supply: 15 mArms DC supply: 9 mA / AC supply: 20 mArms Screw terminals max. 1.5 mm2 (AWG 16) US Version: UL94 V-0 approved / EU Version: UL94 HB approved IP30 Humidity / Temperature alternating EN 61326-1 EN 61326-2-3 Industrial Environment FCC Part 15 ICES-003 Class B -5...55 °C (23...131 °F) -25...60 °C (-13...140 °F) 1) Traceable to international standards, administrated by NIST, PTB, BEV... The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation). The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement). 2) USA & Canada: class 2 supply required, max. supply voltage 30 V
Open the catalog to page 1YOUR PARTNER IN SENSOR TECHNOLOGY, Front cover: signal white RAL9003 Back cover: light grey RAL7035 - EE10 Sensor according to ordering guide - Mounting materials - Test report according to DIN EN 10204-2.2 - Quick user guide (for digital output only) 2) Factory setting: Even Parity, Stopbits 1. 3) Factory setting: No Parity, Stopbits 1. 4) Only for BACnet MS/TP 25 °C (77 °F) < Scale T high < 55 °C (131 °F). Scale T high - Scale T low > 20 °C (68 °F). Modbus Map see User Guide at www.epluse.com/ee10 Product Implementation Conformance Statement (PICS) available at www.epluse.com/ee10
Open the catalog to page 2Order Examples EE10-M1A3D1 Model: Output: Display: Enclosure: Temperature Unit: Scale T low: Scale T high: RH + T 0 - 10 V With display EU-Standard (RAL9003 / RAL7035) °C 0 °C 50 °C EE10-M1J3P3BD7 Model: Output: Display: Enclosure: Protocol: Unit: Baud rate: RH + T RS485 Without display EU-Standard (RAL9003 / RAL7035) BACnet MS/TP Metric (SI) 38 400 v3.3 / Modification rights reserved
Open the catalog to page 34 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
4 Pages
14 Pages
4 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
6 Pages
6 Pages
19 Pages