General Installation Requirements
  • Storage: Maintain temperatures between 4 ºC (40 ºF) and 38 ºC (100 ºF). Specific products may have different minimum temperatures.
  • Application: Avoid applying materials in bad weather unless protected. Ensure temperatures are above 4 ºC (40 ºF) during application and drying.
  • Substrate Inspection: Substrates must be clean, dry, and structurally sound with no irregularities greater than 6.4 mm within a 1.2 m radius.
  • Flashing: Install according to code and contract documents, ensuring proper drainage.
  • Sealants: Ensure Dryvit materials are dry before applying sealants. Refer to DS153 for compatible sealants.
Materials Required
  • Supplied by Dryvit: Includes AquaFlash, Backstop NT, Grid Tape, Flashing Tape, adhesives, drainage materials, and various meshes and finishes.
  • Supplied by Others: Portland Cement, clean water, insulation board, mechanical fasteners, and flashing.
Mixing Instructions
  • General: Do not add any additives to Dryvit materials.
  • Opening Preparation Materials: AquaFlash and Backstop NT require initial mixing with a drill and paddle.
  • Adhesive and Base Coat: Mix Primus or Genesis with Portland cement and water, following specific instructions for consistency and pot life.
Mixing Instructions for Rapidry DM 50-75:
  1. Add 5.2 L of clean potable water to a 19 L pail or mark 97 mm from the base and fill with water.
  2. Slowly add Rapidry DM 50-75 while mixing with a "Twister" paddle at 500-1200 rpm.
  3. Mix until uniformly wetted, adjust consistency with water or material.
  4. Let set for 5 minutes, retemper if necessary.
Mortar Mixer Instructions:
  1. Add 5.2 L of water per 20.4 kg bag of Rapidry DM 50-75.
  2. Mix for 3-5 minutes, let set for 5 minutes, then mix again for 2-3 minutes.
Base Coat Instructions:
  • NCB: Mix to a smooth consistency, add water if needed.
  • Dryflex: Mix thoroughly before adding Portland cement, adjust with water if needed.
Primers and Finishes: Mix various primers and finishes with a "Twister" paddle at 450-500 rpm. Add water to adjust workability.
Specialty Finishes: Mix Ameristone, Stone Mist, TerraNeo, and Lymestone for one minute before application. Do not overmix.
Coatings and Sealers: Mix Demandit, Revyvit, Weathercoat, and others to a homogeneous consistency.
Rough Opening Preparation Options:
  • AquaFlash System: Ensure surfaces are clean and dry. Apply AquaFlash liquid and mesh to openings.
  • Dryvit Backstop NT: Apply when temperatures are above 4°C. Ensure surfaces are clean and dry.
  • Dryvit Flashing Tape: Apply surface conditioner before tape, ensure surfaces are clean and dry.
Dryvit Flashing Tape Application
  • Cut the tape to the required length, peel the release paper, and align it before adhering to the wall.
  • Ensure the tape covers the Backstop NT by 51 mm and turns into the opening.
  • Apply pressure with a hand roller to ensure firm contact with the wall.
  • Maintain a minimum overlap of 51 mm for end laps.
  • In cold weather, use a heat gun for better adhesion.
Sill/Jamb and Head/Jamb Intersections
  • Apply sill piece first, followed by corner splice and jamb pieces.
  • For head/jamb, apply jamb pieces first, then corner splice, and head piece last.
Substrate Expansion Joint Bridging Options
  • AquaFlash System: Overlap AquaFlash Mesh by 51 mm on each side of the joint, apply AquaFlash Liquid, embed the mesh, and apply a second coat.
  • Dryvit Flashing Tape: Apply surface conditioner, allow to dry until tacky, and position tape centered over the joint.
Water-Resistive Barrier Application
  • Two types: Backstop NT liquid membrane and code-compliant sheet membranes.
  • Ensure wall surface and temperature are suitable before application.
  • For sheathing substrates, ensure they are structurally sound and clean.
  • For concrete/masonry, repair cracks and ensure a clean, dry surface.
Backstop NT Application
  • Apply Dryvit Grid Tape on joints and edges before Backstop NT.
  • Backstop NT - Texture can be applied using roller, trowel, or spray equipment.
  • Ensure a continuous film at a dry thickness of approximately 3 mils.
  • For roller application, use a foam roller and ensure joints are dry before proceeding.
  • For trowel application, apply a continuous coating over the entire surface.
  • For spray application, use suitable equipment and ensure a uniform film.
Application of Backstop NT - Texture and Smooth:
  1. Use a foam nap roller to apply Backstop NT - Texture, ensuring a smooth film. If material is pulled from joints, it indicates insufficient drying.
  2. Smooth Backstop NT - Texture around windows and doors while wet.
  3. Apply Backstop NT - Smooth using a roller or spray, ensuring joints are treated beforehand. Apply uniformly and check for voids after drying.
Sheet Membranes Installation:
  1. Install in a weatherboard fashion following manufacturer instructions.
Accessories and Drainage Options:
  • A. Accessories: Install Dryvit Drainage Strip or Track at wall bases and openings. Use adhesive and ensure firm contact.
  • B. Mechanical Fasteners: Use specified washers and screws for different substrates, ensuring proper penetration.
  • C. Drainage Options: Install Dryvit Drainage Mat over water-resistive barriers, ensuring tension to minimize bulging. Use Tyvek StuccoWrap for drainage, ensuring proper lapping and flashing. Secure grooved insulation boards with mechanical fasteners.
Insulation Board Installation:
  • A. Inspection: Ensure insulation boards meet specified tolerances and are properly labeled.
  • B. Preparation at Terminations: Use Detail Mesh for wrapping at terminations. Optionally use Drainage Track for base and openings.
  • C. Mechanical Fastener Attachment: Install insulation boards starting from the base, ensuring offset from sheathing joints. Use specified fasteners and follow recommended patterns.
  • D. Adhesive Attachment: Mix adhesive as per instructions and apply using a notched trowel. Ensure adhesive ribbons run vertically for drainage.
Installation Procedures for Outsulation RMD System
Insulation Board Installation: Ensure uniform contact by applying firm pressure over the insulation board. Clean edges with a margin trowel and ensure joints are tightly abutted. Install subsequent rows in a running bond pattern with staggered vertical joints.
Wall Penetrations: For corners of openings, use L-shaped insulation pieces. Wrap openings with Detail Mesh and allow space for differential movement. Install J-Track at openings, extending beyond edges, and secure with corrosion-resistant fasteners.
Expansion Joints: Leave a 19 mm separation between dissimilar materials and at substrate transitions to allow for movement and sealant installation.
Slivering: Fill gaps greater than 1.6 mm with slivers of insulation board. Do not apply adhesive on sliver edges.
Aesthetic Reveals: Use a chalk line to mark reveals and ensure the insulation board thickness at the bottom is not less than 19 mm. Embed Detail Mesh in the base coat mixture for continuity.
Preparation for Base Coat: Wait 24 hours after installing insulation board before applying the base coat. Sand any irregularities and remove dust. Embed Detail Mesh in the base material mixture.
Reinforcing Mesh and Base Coat Installation: Inspect insulation board for flatness and damage. Apply base coat in two passes to fully embed reinforcing mesh. Use Panzer Mesh for high traffic areas and apply a second layer of reinforcing mesh.
Sealant Joint Preparation: Coat base coat surfaces with Color Prime or Demandit before applying sealant. Allow to dry for 48 hours.
Dryvit Primers: Ensure base coat is cured and dry before applying primers. Correct any irregularities and remove efflorescence.
Dryvit Finish: Ensure base coat is cured and inspect for irregularities before applying the finish.
Application Instructions for Dryvit Outsulation RMD System
General Application Guidelines: Dryvit finishes must be applied continuously to natural breaks like corners or expansion joints. Maintain a wet edge and use materials from a single batch to avoid color variations. Ensure sufficient personnel and scaffolding are available to prevent cold joints. Avoid applying in rain and ensure the base coat is dry before application.
Specific Finish Applications:
  • Quarzputz, Quarzputz E, Sandblast, Weatherlastic Quarzputz: Apply with a stainless steel trowel to a uniform thickness, not exceeding the largest aggregate size.
  • Sandpebble Variants: Apply slightly thicker than the largest aggregate size and use a horizontal trowel motion for uniformity.
  • Freestyle: Apply to a thickness not greater than 1.6 mm, with texture not exceeding 6.4 mm.
  • Weatherlastic Adobe: Apply a coat of Color Prime, followed by two coats of Adobe for desired texture.
  • Ameristone, Stone Mist, TerraNeo, Lymestone, Custom Brick, Reflectit: Follow specific application instructions as per respective data sheets.
Coatings and Sealers: Coatings like Demandit, Weathercoat, Revyvit, Weatherlastic Smooth, Tuscan Glaze, and SealClear should be applied over Dryvit finishes, not directly on the base coat. Specific application techniques include using brushes, rollers, or spray equipment, ensuring even application and avoiding dry rolling.
Maintenance and Repair: Refer to DryvitCARE EIFS Repair Procedures for maintenance guidelines.
Disclaimer: The document provides standard recommendations as of its publication date. For the latest information, contact Dryvit Systems, Inc.
See more

Catalog excerpts

Outsulation® RMD System (formerly Residential MD System®)-1

OUTSULATION® RMD System™ (formerly Residential MD) An Exterior Wall Insulation and Finish System with Drainage Mat OUTSULATION RMD SYSTEM (formerly Residential MD) APPLICATION INSTRUCTIONS DS143

 Open the catalog to page 1
Outsulation® RMD System (formerly Residential MD System®)-2

Outsulation RMD System Application Instructions DS143 2 Table of Contents Section I General Installation Requirements Section II Materials Required for Completing Installation of the Outsulation RMD System Section III Mixing Instructions Section IV Rough Opening Preparation Options Section V Substrate Expansion Joint Bridging Options Section VI Air/Water-Resistive Barrier Application Section VII Accessories and Drainage Options Section VIII Insulation Board Installation Section IX Installation of Reinforcing Mesh and Base Coat Section X Sealant Joint Preparation Section XI Dryvit Primers Section...

 Open the catalog to page 2
Outsulation® RMD System (formerly Residential MD System®)-3

Outsulation RMD System Application Instructions DS143 3 I. General Installation Requirements A. Project Conditions 1. Storage a. Maximum storage temperature shall not exceed 38 ºC (100 ºF). Minimum storage temperature shall not be less than 4 ºC (40 ºF) with the exception of the following products: 1) Demandit, Revyvit and Reflectit™: 7 °C (45 °F) 2) Ameristone, TerraNeo and Lymestone: 10 °C (50 °F) 3) Custom Brick Finish: refer to Custom Brick Polymer Specification, DS151. 2. Application a. Application of wet materials shall not take place during inclement weather unless appropriate protection...

 Open the catalog to page 3
Outsulation® RMD System (formerly Residential MD System®)-4

Outsulation RMD System Application Instructions DS143 4 4. Decks and Patios a. Wood decks shall be properly flashed prior to system application. See the Dryvit Outsulation RMD System Installation Details, DS106 for general information and guidance. b. Verify that the system terminates above poured decks, patios, landings, etc. that are properly sloped and waterproofed to direct water away from the walls. 5. Utilities a. Provisions must be made to ensure that the system terminates properly at lighting fixtures, electrical outlets, hose bibs, dryer vents, etc. Refer to the Dryvit Outsulation RMD...

 Open the catalog to page 4
Outsulation® RMD System (formerly Residential MD System®)-5

Outsulation RMD System Application Instructions DS143 5 2. Backstop NT a. Open the bucket with a utility knife or lid-off. b. Backstop NT is ready to use after an initial spin-up using a “Twister” paddle or equivalent mixing blade, powered by a 12.7 mm (1/2 in) drill, at 450 - 500 rpm. Do not add cement or any other additives. C. Adhesive and Base Coat 1. Primus or Genesis a. Open the bucket with a utility knife or lid-off. b. Due to shipping and storage, there may be some separation of materials. Prior to splitting the material and adding Portland cement, mix the material thoroughly. Use a “Twister”...

 Open the catalog to page 5
Outsulation® RMD System (formerly Residential MD System®)-6

Outsulation RMD System Application Instructions DS143 6 b. Mortar Mixer 1) Add 5.7 - 6.6 L (6 - 7 qt) of clean potable water for each 22.7 kg (50 lb.) bag of Genesis DM into a clean mortar mixer. 2) Add the Genesis DM while the mixer is running. Let mix three to five (3 – 5) minutes, shut the mixer off for ten (10) minutes, then run mixer for another two to three (2 – 3) minutes to break the set adding a small amount of water if necessary to adjust workability. The pot life is one to one and one half (1 – 1 ½) hours depending on weather. 4. Genesis DMS a. Sprayer 1) Connect a source of clean,...

 Open the catalog to page 6
Outsulation® RMD System (formerly Residential MD System®)-7

Outsulation RMD System Application Instructions DS143 7 b. Mortar Mixer 1) Add 5.2 L (5.5 qt) of clean potable water for each 20.4 kg (45 lb) bag of Rapidry DM 50-75 into a clean mortar mixer. 2) Add the Rapidry DM 50-75 while the mixer is running. Mix for 3 to 5 minutes, shut the mixer off for 5 minutes, then run mixer for another 2 to 3 minutes to break the set adjusting consistency with a small amount of water or Rapidry DM 50-75. The pot life is approximately 30 minutes depending on temperature. D. Base Coat only 1. NCB a. Open the bucket with a utility knife or lid-off. b. Mix NCB to a smooth,...

 Open the catalog to page 7
Outsulation® RMD System (formerly Residential MD System®)-8

Outsulation RMD System Application Instructions DS143 8 4. Lymestone™ a. Mix Lymestone with a “Twister” paddle or equivalent mixing blade, powered by a 12.7 mm (1/2 in) drill, at 450 - 500 rpm until a uniform workable consistency is attained. NOTE: If using a tint pack to color finish, please refer to Tint Pack Mixing Instructions, DS750. 5. Custom Brick™ Finishes a. For Custom Brick finishes, refer to Dryvit Custom Brick Application Instructions, DS154, for complete mixing instructions. NOTE: If using a tint pack to color finish, please refer to Tint Pack Mixing Instructions, DS750. 6. Reflectit...

 Open the catalog to page 8
Outsulation® RMD System (formerly Residential MD System®)-9

Outsulation RMD System Application Instructions DS143 9 3) Immediately lay the AquaFlash Mesh into the wet material and brush smooth adding additional material to completely embed the mesh - Figure 2. 4) Install the AquaFlash System at the jambs in the same manner extending 51 mm (2 in) above the head and overlapping onto the sill material a minimum of 51 mm (2 in) – Figure 3. 5) Install the AquaFlash System at the head overlapping the jamb pieces a minimum of 51 mm (2 in) – Figure 4. Figure 4 6) Install diagonal “butterflies” consisting of AquaFlash Liquid and AquaFlash Mesh at each sill/jamb...

 Open the catalog to page 9
Outsulation® RMD System (formerly Residential MD System®)-10

Outsulation RMD System Application Instructions DS143 10 7) Allow material to set for approximately 15 minutes then apply a second liberal coat of AquaFlash liquid and smooth out to ensure a continuous film free of voids, pinholes, or other discontinuities. 4. Sill Pan Flashing (Exposed) a. Install a watertight pan flashing at all sill locations - Figure 6. b. The flashing shall extend between the framing members of the rough opening and shall be sized to protect the sill, sheathing and the surface of the Outsulation RMD System. It must include vertical legs at the back and sides to ensure proper...

 Open the catalog to page 10
Outsulation® RMD System (formerly Residential MD System®)-11

Outsulation RMD System Application Instructions DS143 11 h. Allow material to set for 15 minutes then apply a second liberal coat of AquaFlash liquid and smooth out to ensure a continuous film free of voids, pinholes, or other discontinuities and allow to dry. B. Dryvit Backstop NT option 1. Surface Preparation a. Apply only when air and surface temperatures are above 4 °C (40 °F). b. The surface to receive the Backstop NT must be clean, dry, smooth and free of any other condition that will hinder adhesion. c. Remove loose dust or dirt from the surface by wiping with a clean, dry cloth or brush....