Overview: The document provides comprehensive installation details for the INFINITY® System, a pressure-equalized rainscreen exterior insulation and finish system by Dryvit Systems, Inc. It covers specifications, procedures, norms, standards, and recommendations for the system's components and installation.
Specifications: The INFINITY® System is designed to meet local building codes and standards. Key components include the I.S. Insulation Board™, Dryvit Vent Assembly™, and various reinforcing meshes. The system is suitable for building facades, with specific instructions for high-impact zones and ground floor applications. It emphasizes the use of compatible sealants and backer rods, with minimum dimensions specified for installation components.
Procedures: Installation involves using Dryvit adhesives in a vertical notched trowel configuration and applying reinforcing meshes like Panzer® Mesh in high-stress areas. Procedures include sanding surfaces for better adhesion, correct placement of sealant joints, and wrapping mesh around insulation boards. The use of Dryvit Flashing Tape and Surface Conditioner is advised for enhanced adhesion and sealing.
Norms and Standards: Compliance with local building codes and standards is mandatory. The document places responsibility on the project's design professional to ensure architectural and engineering requirements are met, disclaiming liability for design and workmanship.
Recommendations: For high-traffic or impact-prone areas, reinforcing the base coat with Panzer® Mesh is recommended. High impact zones should be clearly indicated in contract drawings. The document suggests using functionally equivalent details without violating Dryvit's warranty.
Limitations: The document specifies that the percentage of wall area covered by EPS foam shapes exceeding 102 mm (4 inches) in thickness should not exceed 15%, with a maximum thickness of 305 mm (12 inches).
Best Practices: To minimize cracking at corners, diagonal reinforcing mesh should be installed, and insulation boards should be positioned to avoid alignment with penetration corners. Proper drainage slopes are recommended to ensure effective water runoff.
Key Details: Detailed illustrations and notes are provided on groove patterns, compartment separation, and termination at concrete. Guidance is given on using compatible sealants and maintaining updated installation details.
See more

Catalog excerpts

Infinity® System-1

INFINITY® SYSTEM A Pressure-Equalized Rainscreen Exterior Insulation and Finish System Infinity Installation Details DS120

 Open the catalog to page 1
Infinity® System-2

INFINITY®SYSTEM - GROOVE PATTERN DRYVIT SYSTEMS, INC. MAKES NO REPRESENTATION REGARDING CONFORMITY OF ITS SUGGESTIONS TO MODEL BUILDING CODES, ENGINEERING CRITERIA, SPECIFIC APPLICATIONS OR PROJECT LOCATIONS. ALL COMPONENTS INDICATED IN ILLUSTRATIONS, AS WELL AS OTHERS THAT MAY BE REQUIRED FOR THE INTEGRITY OF THE SYSTEM SHALL BE DESIGNED, DETAILED AND ENGINEERED BY REPRESENTATIVES OF THE ARCHITECT, OWNER OR CONTRACTOR TO BE IN CONFORMANCE WITH MODEL CODES, ARCHITECTURAL AND ENGINEERING REQUIREMENTS PERTAINING TO SPECIFIC BUILDING PROJECTS. DRYVIT SYSTEMS, INC. MAKES NO WARRANTY, EXPRESSED OR...

 Open the catalog to page 2
Infinity® System-3

4 10/06 IS 0.0.01 NOTE: DRYVIT RECOMMENDS THAT GROUND FLOOR APPLICATIONS AND ALL FACADES EXPOSED TO ABNORMAL STRESS, HIGH TRAFFIC, OR DELIBERATE IMPACT HAVE THE BASE COAT REINFORCED WITH PANZER® MESH PRIOR TO I.S. REINFORCING MESH™. LOCATION OF HIGH IMPACT ZONES SHOULD BE INDICATED ON CONTRACT DRAWINGS. 1. APPROVED BY: RS REV: without notice. Contact Dryvit to insure you have the most recent does not violate Dryvit's warranty. This detail is subject to change is best suited for the project. Use of a functionally equivalent detail discretion, whether this detail or a functionally equivalent alternative...

 Open the catalog to page 3
Infinity® System-4

Building Facade IS 0.0.02 3 10/06 APPROVED BY: RS REV: without notice. Contact Dryvit to insure you have the most recent does not violate Dryvit's warranty. This detail is subject to change is best suited for the project. Use of a functionally equivalent detail discretion, whether this detail or a functionally equivalent alternative any project. The project design professional determines, in its sole detail and for the architecture, design, engineering or workmanship of and Dryvit specifically disclaims any liability for the use of this standards. This detail is for general information and guidance...

 Open the catalog to page 4
Infinity® System-5

DRYVIT VENT ASSEMBLY™ DRYVIT STARTER STRIP The architecture, engineering and design of the project using the Dryvit products is the responsibility of the project's design professional. All systems must comply with local building codes and standards. This detail is for general information and guidance only and Dryvit specifically disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. The project design professional determines, in its sole discretion, whether this detail or a functionally equivalent alternative is best suited...

 Open the catalog to page 5
Infinity® System-6

610 MM (2'-0") DRYVIT STARTER STRIP VERTICAL GROOVES (ALIGNED) DRYVIT VENT ASSEMBLY™ The architecture, engineering and design of the project using the Dryvit products is the responsibility of the project's design professional. All systems must comply with local building codes and standards. This detail is for general information and guidance only and Dryvit specifically disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. The project design professional determines, in its sole discretion, whether this detail or a functionally...

 Open the catalog to page 6
Infinity® System-7

45 I.S. Insulation Board- Groove Pattern 3 10/06 IS 0.0.05 APPROVED BY: RS REV: without notice. Contact Dryvit to insure you have the most recent does not violate Dryvit's warranty. This detail is subject to change is best suited for the project. Use of a functionally equivalent detail discretion, whether this detail or a functionally equivalent alternative any project. The project design professional determines, in its sole detail and for the architecture, design, engineering or workmanship of and Dryvit specifically disclaims any liability for the use of this standards. This detail is for general...

 Open the catalog to page 7
Infinity® System-8

DRYVIT AP ADHESIVE (SEE NOTE 2) DRYVIT VENT TRACK™ DRYVIT STARTER STRIP (SEE NOTE 1) I.S. INSULATION BOARD CLOSURE BLOCK (SEE NOTE 1) INFINITY®SYSTEM FILL DRYVIT VENT TRACK AT CLOSURE BLOCK LOCATION WITH AP ADHESIVE PRIOR TO SETTING CLOSURE BLOCK, TO PROVIDE COMPARTMENT CLOSURE. ADHERE CLOSURE BLOCKS AND STARTER STRIPS USING "RIBBON & DAB" ADHESIVE PATTERN TO PROVIDE COMPARTMENT CLOSURE. 2. NOTES: 1. APPROVED BY: RS REV: 3 DRYVIT BACKSTOP® NT APPROVED SUBSTRATE FRAMING I.S. INSULATION BOARD™ VERTICAL GROOVES (ALIGNED) DRYVIT VENT ASSEMBLY™ The architecture, engineering and design of the project...

 Open the catalog to page 8
Infinity® System-9

without notice. Contact Dryvit to insure you have the most recent does not violate Dryvit's warranty. This detail is subject to change is best suited for the project. Use of a functionally equivalent detail discretion, whether this detail or a functionally equivalent alternative of any project. The project design professional determines, in its sole detail and for the architecture, design, engineering or workmanship and Dryvit specifically disclaims any liability for the use of this standards. This detail is for general information and guidance only professional. All systems must comply with...

 Open the catalog to page 9
Infinity® System-10

professional. All systems must comply with local building codes and standards. This detail is for general information and guidance only and Dryvit specifically disclaims any liability for the use of this detail and for the architecture, design, engineering or workmanship of any project. The project design professional determines, in its sole discretion, whether this detail or a functionally equivalent alternative is best suited for the project. Use of a functionally equivalent detail does not violate Dryvit's warranty. This detail is subject to change without notice. Contact Dryvit to insure...

 Open the catalog to page 10
Infinity® System-11

12.7 MM (1/2") DATE: 4 10/06 REV: AS AN OPTION DRYVIT FLASHING TAPE SURFACE CONDITIONER™ AND DRYVIT FLASHING TAPE™ CAN BE USED. LIGHTLY SAND SURFACE OF TRACK TO MAXIMIZE ADHESION. SEALANT SHOULD NOT BE IN DIRECT CONTACT WITH ASPHALTIC ADHESIVE ON DRYVIT FLASHING TAPE. COVER DRYVIT FLASHING TAPE LAPS WITH POLYETHYLENE TAPE OR BACKER ROD. The architecture, engineering and design of the project using the Dryvit products is the responsibility of the project's design professional. All systems must comply with local building codes and standards. This detail is for general information and guidance only...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.