VMZINC - 1

PROJECT NAME PROJECT LOCATION SECTION 07 42 13.26 ZINC ALLOY METAL PLATE WALL PANELS Zinc alloy metal plate wall panels. Section 06 1000 – Rough Carpentry: Plywood substrate wall sheathing Section 07 2500 – Weather Barriers: Air and moisture barrier required as part of metal wall panel assembly. Section 07 6200 – Sheet Metal Flashing and Trim: Field formed flashings and other sheet metal work. Section 05 4000 – Cold-Formed Metal Framing: Wall panel substrates support framing. Section 07 9005 – Joint Sealers: Perimeter sealant. Metal Plate Wall Panel Assembly: Metal plate wall panels, attachment system components, miscellaneous metal framing, and accessories necessary for a complete weather tight wall system based on AAMA CW-RS-1. ASTM International (American Society for Testing and Materials; www.astm.org) 1. ASTM B 69 - Standard Specification for Rolled Zinc; 2011 2. ASTM C 754 - Standard Specification for Installation of Steel Framing Members to Receive ScrewAttached Gypsum Panel Products; 2009 3. ASTM E 18 - Standard Test Methods for Rockwell Hardness of Metallic Materials; 2011 4. ASTM E 283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen; 2004. 5. ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference; 2010 6. ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference; 2009 7. ASTM E 1233 – Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Cyclic Air Pressure Differential; 2006 LEED – Leadership in Energy and Environmental Design SMACNA – Sheet Metal and Air Conditioning Contractor’s National Association AAMA - American Architectural Manufacturers Association (www.aamanet.org) 1. AAMA CW-RS-1 – The Rain Screen Principle and Pressure Equalized Wall Design; 2004 2. AAMA 501.1 – Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure; 2005 3. AAMA 501.2 - Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems; 2009 4. AAMA 508 – Voluntary Test Method and Specification for Pressure Equalized Rain Screen Wall Cladding Systems; 2007 PS - Voluntary Product Standard; National Institute of Standards and Technology (NIST) 1. PS-1 – Structural Plywood; 2007 ADMINISTRATIVE REQUIREMENTS AUTHOR FILE NAME ZINC ALLOY METAL PLATE WALL PANELS 07 4213.26 - 1

Open the catalog to page 1
VMZINC - 2

PROJECT NAME PROJECT LOCATION Coordination: Coordinate panel assemblies with rain drainage, flashing, trim, stud back-up, soffits, and other adjoining work. Preinstallation Meeting: 1. Attendees: a. Owner. b. Architect. c. Installer. d. Panel manufacturer's representative. e. Structural support installer. f. Installer’s whose work interfaces with or affects wall panels including installers of doors, windows, and louvers. 2. Review and finalize construction schedule. 3. Verify availability of materials, installer's personnel, equipment, and facilities needed to maintain schedule. 4. Review...

Open the catalog to page 2
VMZINC - 3

PROJECT NO.: PROJECT NAME DATE: PROJECT LOCATION A. Manufacturer Qualifications: Company specializing in manufacturing products specified in this section with at least five years of documented experience. B. Installer: Company specializing in performing work of this section and approved by manufacturer. 1. Install system in strict compliance with manufacturer's installation instructions. C. Source Limitations: Obtain each type of metal plate wall panel from single source and from single A. Mockups: Provide mockups to verify selections made under sample submittals and to demonstrate...

Open the catalog to page 3
VMZINC - 4

PROJECT NAME PROJECT LOCATION Wall System Warranty: Provide wall panel manufacturer warranty, agreeing to correct defects in manufacturing of materials within one year period after date of Substantial Completion. 1. Failures include, but are not limited to, the following: a. Structural failures, including rupturing, cracking, or puncturing. b. Deterioration: Beyond normal weathering of wall system metals and other materials. Panel Finish Warranty: Provide panel finish manufacturer warranty, agreeing to repair finish of metal plate wall panels that show evidence of corrosive deterioration...

Open the catalog to page 4
VMZINC - 5

PROJECT NAME PROJECT LOCATION a. Quartz Zinc; zinc finish with dark grey aspect. 1) Luminance Scale: Y-Factor range of 22-25. b. Anthra Zinc; zinc with black aspect. 1) Luminance Scale: Y-Factor range of 5-7. Pigmented Preweathered Zinc: a. Pigmento Blue, zinc with blue pigmented aspect. b. Pigmento Red, zinc with red pigmented aspect. c. Pigmento Green, zinc with green pigmented aspect. d. Pigmento Clear (Strat), zinc with clear pigmented aspect. Fabricate and finish wall panels within manufacturer’s facilities and fulfill indicated performance requirements demonstrated by laboratory...

Open the catalog to page 5
VMZINC - 6

PROJECT NAME PROJECT LOCATION Miscellaneous Framing: Install sub-girt, base angles, sills, furring, and other wall panel support members and provide anchorage in accordance with ASTM C 754 for gypsum panel type substrates and panel manufacturer’s installation instructions. Install wall panels in accordance with manufacturer's installation instructions, including pressure equalized rainscreen installation method and installation guidelines. 1. Wall panels consist of single sheets of metal formed with interlocking gutter and drainage system integral to the panel with single horizontal...

Open the catalog to page 6
VMZINC - 7

PROJECT NAME PROJECT LOCATION Shim and align wall panel units with installed tolerances of 1/4 inch in 20 feet, non-cumulative, on level, plumb, and location lines as indicated. FIELD QUALITY CONTROL A. B. Water-Spray Test: After installation and in coordination with Mockup requirements, test area of assembly [shown on Drawings] [as directed by Architect] or for water penetration in accordance with AAMA 501.2. Manufacturer's Field Service: Engage a factory-authorized service representative to test and inspect completed metal wall panel installation, including accessories. Remove and replace...