video corpo cad

TAPERED
9Pages

{{requestButtons}}

Catalog excerpts

TAPERED - 1

PROJECT NAME PROJECT LOCATION SECTION 07 4213.31 TAPERED METAL PLATE WALL PANELS PART 1 - GENERAL 1.01 Tapered [aluminum] or [zinc alloy] metal plate wall panels. Section 06 1000 – Rough Carpentry: Plywood substrate wall sheathing. Section 07 2500 – Weather Barriers: Air and moisture barrier required as part of metal wall panel assembly. Section 07 6200 – Sheet Metal Flashing and Trim: Field formed flashings and other sheet metal work. Section 05 4000 – Cold-Formed Metal Framing: Wall panel substrates support framing. Section 07 9005 – Joint Sealers: Perimeter sealant. Metal Plate Wall Panel Assembly: Metal plate wall panels, attachment system components, miscellaneous metal framing, and accessories necessary for a complete weather tight wall system based on AAMA CW-RS-1. AAMA - American Architectural Manufacturers Association (www.aamanet.org) 1. AAMA CW-RS-1 – The Rain Screen Principle and Pressure Equalized Wall Design; 2004 2. AAMA 501.1 – Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure; 2005 3. AAMA 501.2 - Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems; 2009 4. AAMA 508 – Voluntary Test Method and Specification for Pressure Equalized Rain Screen Wall Cladding Systems; 2007 5. AAMA 611 - Voluntary Standards for Anodized Architectural Aluminum; 1998 6. AAMA 2605 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels; 2011 (Testing based on 2005 Edition) ASTM International (American Society for Testing and Materials; www.astm.org) 1. ASTM B 69 - Standard Specification for Rolled Zinc; 2011 1. ASTM B 117 - Standard Practice for Operating Salt Spray (Fog) Apparatus; 2011 2. ASTM C 754 - Standard Specification for Installation of Steel Framing Members to Receive ScrewAttached Gypsum Panel Products; 2009 3. ASTM D 523 - Standard Test Method for Specular Gloss; 2008 4. ASTM D 2244 – Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates; 2011 5. ASTM D 2247 - Standard Practice for Testing Water Resistance of Coatings in 100% Relative Humidity; 2011 6. ASTM D 4214 - Standard Test Methods for Evaluating the Degree of Chalking of Exterior Paint Films; 2007 AUTHOR FILE NAME TAPERED METAL PLATE WALL PANELS 07 4213.31 - 1

Open the catalog to page 1
TAPERED - 2

PROJECT NAME PROJECT LOCATION ASTM E 8/E 8M - Standard Test Methods for Tension Testing of Metallic Materials; 2009 ASTM E 18 - Standard Test Methods for Rockwell Hardness of Metallic Materials; 2011 ASTM E 283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen; 2004. 10. ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference; 2010 11. ASTM E 331 - Standard Test Method for...

Open the catalog to page 2
TAPERED - 3

PROJECT NAME PROJECT LOCATION a. b. Manufacturer’s standard sheet metal trims. Components of wall panel construction, anchorage methods, and hardware. Samples: Submit for each type of exposed finish required, and prepared on samples of size as follows: 1. [Aluminum] or [Zinc Alloy] Metal Plate Wall Panels: At least 2 inch by 3 inch. Test and Inspection Reports: Submit test and inspection reports on each type of wall panel system provided for project based on evaluation of comprehensive tests performed by qualified testing agency. Maintenance Data: Submit maintenance data for metal plate...

Open the catalog to page 3
TAPERED - 4

PROJECT NAME PROJECT LOCATION Deliver panels, components, and other manufactured items without damage or deformation. Protect panels during transportation, handling, and installation from weather, excessive temperatures and construction operations. Handle panels in strict compliance with manufacturer’s instructions and recommendations, and in a manner to prevent bending, warping, twisting, and surface damage. 1. Store panels vertically with top of panel down, storage of panels horizontally is not permitted. Store panels covered with suitable weather tight and ventilated covering. Provide...

Open the catalog to page 4
TAPERED - 5

PROJECT NAME PROJECT LOCATION b. c. d. Fading, Loss of Color Retention: Loss of 5 Delta E units (Hunter) or less in accordance with ASTM D 2244. Chalking, Chalky White Powder on Panel Surface: Chalking at No. 8 or less in accordance with ASTM D 4214. Salt Spray, Accelerated: At least 3,000 hours in accordance with ASTM B 117. Dri-Design - Wall Panel System; Product Tapered Series. 1. Address: 12480 Superior Ct., Holland, Michigan 49424. 2. P.O. Box 1286 Holland, Michigan 49422-1286. 3. Phone: (616) 355-2970; Fax: (616) 355-2972; Website: www.dri-design.com. Zinc Alloy Plate Material...

Open the catalog to page 5
TAPERED - 6

PROJECT NAME PROJECT LOCATION Panel Depth: 1 1/4 inch, nominal. Panel Size: As indicated on Drawings. Aluminum Plate: Alloy and temper as recommended by manufacturer for application and in compliance with manufacturers design requirements. 1. Aluminum Material: Tension-leveled, [flouropolymer PVDF painted finish 3003-H14 manganese alloy] or [anodized finish 5005-AQ manganese alloy]. 2. Thickness: [0.062 inch] or [0.080 inch]. 3. Weight: Less than 2 lbs per sf. 4. Finish: [Two-Coat Fluoropolymer] [Three-Coat Fluoropolymer] [Four-Coat Fluoropolymer] [TwoCoat Mica Fluoropolymer] [Clear...

Open the catalog to page 6
TAPERED - 7

PROJECT NAME PROJECT LOCATION Color Anodized Finish: AAMA 611, Class I, colored anodic coating not less than 0.7 mils thick. 1. Color: [_____] or [As selected by Architect]. Clear Anodized Finish: AAMA 611, Class I, clear anodic coating not less than 0.7 mils thick. Superior Performance Organic Coating System: AAMA 2605 multiple coat, thermally cured polyvinylidene fluoride (PVDF) resin system. 1. Two-Coat Fluoropolymer: AAMA 2605, fluoropolymer finish containing not less than 70 percent PVDF resin by weight in color coat. Prepare, pre-treat, and apply coating to exposed metal surfaces to...

Open the catalog to page 7

All Dri Design catalogs and technical brochures

  1. SHADOWED

    9 Pages

  2. VMZINC