General Overview
This document provides a comprehensive guide on the specifications and requirements for stainless steel metal plate wall panels. It covers related requirements, definitions, reference standards, administrative requirements, submittals, quality assurance, mockups, delivery, storage, handling, site conditions, and warranty.
Specifications
The document specifies the use of stainless steel metal plate wall panels, detailing components necessary for a complete weather-tight wall system. It references standards from organizations such as AAMA and ASTM to ensure compliance with industry norms for water penetration, structural performance, and air leakage.
Procedures
Administrative requirements include coordination of panel assemblies with other construction elements, preinstallation meetings, and detailed submittal procedures. The importance of mockups is emphasized to verify selections and establish quality standards.
Standards and Testing
Reference standards include AAMA CW-RS-1 for rain screen principles and ASTM standards for structural and water penetration tests. Compliance with these standards is mandated to ensure the performance and durability of the wall panel system.
Recommendations
Recommendations include using a single source for metal plate wall panels, ensuring manufacturer and installer qualifications, and conducting field measurements before fabrication. Proper delivery, storage, and handling are advised to prevent damage.
Key Requirements
Key requirements include a warranty for the wall system and panel finish, compliance with LEED for sustainable design, and specific performance criteria for air infiltration and water penetration. Materials, finishes, and accessories necessary for the wall panel assembly are specified.
Critical Information
Critical information includes the need for a dry joint, pressure-equalized rainscreen system, and the use of stainless steel Type 304 or 316 with a No. 4 Bright Polished finish. The importance of maintaining a positive slope for drainage during storage and ensuring panels are not stored in contact with materials that could cause damage is outlined.
Examination
Before installation, examine substrates, work areas, and conditions to ensure compliance with installation tolerances and wall panel supports. Verify the installation of structural support members and weather barriers to prevent air infiltration or water penetration. Coordinate penetration locations relative to wall panel joints.
Preparation
Install miscellaneous framing such as sub-girts and base angles according to ASTM C 754 and manufacturer’s instructions.
Installation
Install wall panels following the manufacturer's instructions, using a pressure equalized rainscreen method. Panels should interlock progressively, allowing for thermal expansion. Ensure proper anchorage and weather-tight seals at panel openings. Flashing and trim should comply with SMACNA standards, ensuring watertight seams.
Tolerances
Align wall panel units with a tolerance of 1/4 inch in 20 feet, non-cumulative.
Field Quality Control
Engage a qualified testing agency for field tests and inspections, including water-spray tests for water penetration. Replace panels that do not meet specifications and perform additional tests as needed.
Cleaning
Clean finished surfaces and clear weep holes and drainage channels upon completion of installation.
Protection
Protect installed products from damage during further construction and replace any panels that are damaged beyond repair.
See more

Catalog excerpts

STAINLESS STEEL METAL PLATE-1

PROJECT(NO.:( DATE:( PROJECT(NAME( PROJECT(LOCATION( SECTION(07(4213.27( STAINLESS(STEEL(METAL(PLATE(WALL(PANELS( ( PART 1( GENERAL 1.01( SECTION INCLUDES A.( Stainless steel metal plate wall panels. ( 1.02( RELATED REQUIREMENTS A.( Section 05 4000 – Cold-Formed Metal Framing: Wall panel substrates support framing. B.( Section 06 1000 – Rough Carpentry: Plywood substrate wall sheathing. C.( Section 07 2500 – Weather Barriers: Air and moisture barrier required as part of metal wall panel assembly. D.( Section 07 6200 – Sheet Metal Flashing and Trim: Field formed flashings and other sheet metal work. E.( Section 07 9005 – Joint Sealers: Perimeter sealant. 1.03( DEFINITION A.( Metal Plate Wall Panel Assembly: Metal plate wall panels, attachment system components, miscellaneous metal framing, and accessories necessary for a complete weather tight wall system based on AAMA CW-RS-1. ( 1.04( REFERENCE STANDARDS A.( AAMA - American Architectural Manufacturers Association (www.aamanet.org) 1.( AAMA CW-RS-1 – The Rain Screen Principle and Pressure Equalized Wall Design; 2004 2.( AAMA 501.1 – Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure; 2005 3.( AAMA 501.2 - Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems; 2009 4.( AAMA 508 – Voluntary Test Method and Specification for Pressure Equalized Rain Screen Wall Cladding Systems; 2007 B.( ASTM International (American Society for Testing and Materials; www.astm.org) 1.( ASTM C 754 - Standard Specification for Installation of Steel Framing Members to Receive ScrewAttached Gypsum Panel Products; 2009 2.( ASTM E 283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen; 2004. 3.( ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference; 2010 4.( ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference; 2009 5.( ASTM E 1233 – Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Cyclic Air Pressure Differential; 2006 C.( LEED – Leadership in Energy and Environmental Design D.( NAAMM – National Association of Architectural Metal Manufacturers AUTHOR((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((STAINLESS(STEEL(METAL(PLATE(WALL(PANELS( FILE(NAME((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((07(4213.27(<(1(

 Open the catalog to page 1
STAINLESS STEEL METAL PLATE-2

PROJECT(NO.:( DATE:( PROJECT(NAME( PROJECT(LOCATION( SMACNA – Sheet Metal and Air Conditioning Contractor’s National Association PS - Voluntary Product Standard; National Institute of Standards and Technology (NIST) 1.( PS-1 – Structural Plywood; 2007 1.05( ADMINISTRATIVE REQUIREMENTS A.( Coordination: Coordinate panel assemblies with rain drainage, flashing, trim, stud back-up, soffits, and other adjoining work. ( B.( Preinstallation Meeting: 1.( Attendees: a.( Owner. b.( Architect. c.( Installer. d.( Panel manufacturer's representative. e.( Structural support installer. f.( Installer’s whose...

 Open the catalog to page 2
STAINLESS STEEL METAL PLATE-3

PROJECT(NAME( PROJECT(LOCATION( Test and Inspection Reports: Submit test and inspection reports on each type of wall panel system provided for project based on evaluation of comprehensive tests performed by qualified testing agency. G.( Maintenance Data: Submit maintenance data for metal plate wall panels. ( H.( Warranty: Submit manufacturer warranty and ensure forms have been completed in Owner's name and registered with manufacturer. ( I.( Sustainable Design Submittals [LEED Reports]: 1.( Submit documentation from manufacturer for amounts of pre-consumer and post-consumer recycled content for...

 Open the catalog to page 3
STAINLESS STEEL METAL PLATE-4

PROJECT(NAME( PROJECT(LOCATION( Store panels covered with suitable weather tight and ventilated covering. G.( Provide storage of panels to ensure dryness, with positive slope for drainage of moisture. H.( Do not store panels in contact with other materials that might cause staining, denting, or other surface damage. I.( Remove strippable protective covering from stainless steel panel prior to installation. 1.10( SITE CONDITIONS A.( Weather Limitations: Proceed with installation only when existing and forecasted weather conditions permit assembly of this Work to be performed according to manufacturer's...

 Open the catalog to page 4
STAINLESS STEEL METAL PLATE-5

PROJECT(NO.:( DATE:( PROJECT(NAME( PROJECT(LOCATION( Dynamic: Pass water penetration test under dynamic pressure of 6.24 psf in accordance with AAMA 501.1. Structural: Provide systems tested in accordance with ASTM E 330 and certified to be without permanent deformation or failure of structural members. ( 2.03( MATERIALS A.( Stainless Steel Plate: Alloy and temper as recommended by manufacturer for application and in compliance with manufacturers performance requirements. 1.( Stainless Steel Material: [Type 304] or [Type 316]. 2.( Thickness: [18 gage] or [22 gage]. 3.( Finish: No. 4 Bright Polished....

 Open the catalog to page 5
STAINLESS STEEL METAL PLATE-6

PROJECT(NO.:( DATE:( PROJECT(NAME( PROJECT(LOCATION( G.( Weather Barriers: Provide climate specific weather barrier with performance characteristics for air penetration, water vapor transmission, and water penetration resistance. 1.( Refer to Section 07 2500 for requirements. PART 3(- EXECUTION 3.01( EXAMINATION A.( Examine substrates, and Work areas and conditions with Installer present for compliance with requirements for installation tolerances, wall panel supports, and other conditions affecting performance of this Work. B.( Examine wall framing to verify that girts, angles, channels, studs,...

 Open the catalog to page 6
STAINLESS STEEL METAL PLATE-7

PROJECT(NO.:( DATE:( PROJECT(NAME( PROJECT(LOCATION( H.( Install weather tight escutcheons for pipe and conduit penetrating exterior walls. I.( Metal Protection: Where dissimilar metals will contact each other or corrosive substrates, protect against galvanic action as recommended by wall panel manufacturer. Install attachment system to support wall panels and with provisions to provide a complete weather tight wall system, including sub girts, extrusions, flashings and trim. 1.( Include attachment to supports and trims at locations using dissimilar materials. 2.( Do not apply sealants to joints,...

 Open the catalog to page 7

All Dri Design catalogs and technical brochures

  1. SHADOWED

    9  Pages

  2. TAPERED

    9  Pages

  3. VMZINC

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.