STAINLESS STEEL METAL PLATE - 1

PROJECT(NO.:( DATE:( PROJECT(NAME( PROJECT(LOCATION( SECTION(07(4213.27( STAINLESS(STEEL(METAL(PLATE(WALL(PANELS( ( PART 1( GENERAL 1.01( SECTION INCLUDES A.( Stainless steel metal plate wall panels. ( 1.02( RELATED REQUIREMENTS A.( Section 05 4000 – Cold-Formed Metal Framing: Wall panel substrates support framing. B.( Section 06 1000 – Rough Carpentry: Plywood substrate wall sheathing. C.( Section 07 2500 – Weather Barriers: Air and moisture barrier required as part of metal wall panel assembly. D.( Section 07 6200 – Sheet Metal Flashing and Trim: Field formed flashings and other sheet metal work. E.( Section 07 9005 – Joint Sealers: Perimeter sealant. 1.03( DEFINITION A.( Metal Plate Wall Panel Assembly: Metal plate wall panels, attachment system components, miscellaneous metal framing, and accessories necessary for a complete weather tight wall system based on AAMA CW-RS-1. ( 1.04( REFERENCE STANDARDS A.( AAMA - American Architectural Manufacturers Association (www.aamanet.org) 1.( AAMA CW-RS-1 – The Rain Screen Principle and Pressure Equalized Wall Design; 2004 2.( AAMA 501.1 – Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure; 2005 3.( AAMA 501.2 - Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems; 2009 4.( AAMA 508 – Voluntary Test Method and Specification for Pressure Equalized Rain Screen Wall Cladding Systems; 2007 B.( ASTM International (American Society for Testing and Materials; www.astm.org) 1.( ASTM C 754 - Standard Specification for Installation of Steel Framing Members to Receive ScrewAttached Gypsum Panel Products; 2009 2.( ASTM E 283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen; 2004. 3.( ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference; 2010 4.( ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference; 2009 5.( ASTM E 1233 – Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Cyclic Air Pressure Differential; 2006 C.( LEED – Leadership in Energy and Environmental Design D.( NAAMM – National Association of Architectural Metal Manufacturers AUTHOR((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((STAINLESS(STEEL(METAL(PLATE(WALL(PANELS( FILE(NAME((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((((07(4213.27(<(1(

Open the catalog to page 1
STAINLESS STEEL METAL PLATE - 2

PROJECT(NO.:( DATE:( PROJECT(NAME( PROJECT(LOCATION( SMACNA – Sheet Metal and Air Conditioning Contractor’s National Association PS - Voluntary Product Standard; National Institute of Standards and Technology (NIST) 1.( PS-1 – Structural Plywood; 2007 1.05( ADMINISTRATIVE REQUIREMENTS A.( Coordination: Coordinate panel assemblies with rain drainage, flashing, trim, stud back-up, soffits, and other adjoining work. ( B.( Preinstallation Meeting: 1.( Attendees: a.( Owner. b.( Architect. c.( Installer. d.( Panel manufacturer's representative. e.( Structural support installer. f.( Installer’s...

Open the catalog to page 2
STAINLESS STEEL METAL PLATE - 3

PROJECT(NAME( PROJECT(LOCATION( Test and Inspection Reports: Submit test and inspection reports on each type of wall panel system provided for project based on evaluation of comprehensive tests performed by qualified testing agency. G.( Maintenance Data: Submit maintenance data for metal plate wall panels. ( H.( Warranty: Submit manufacturer warranty and ensure forms have been completed in Owner's name and registered with manufacturer. ( I.( Sustainable Design Submittals [LEED Reports]: 1.( Submit documentation from manufacturer for amounts of pre-consumer and post-consumer recycled content...

Open the catalog to page 3
STAINLESS STEEL METAL PLATE - 4

PROJECT(NAME( PROJECT(LOCATION( Store panels covered with suitable weather tight and ventilated covering. G.( Provide storage of panels to ensure dryness, with positive slope for drainage of moisture. H.( Do not store panels in contact with other materials that might cause staining, denting, or other surface damage. I.( Remove strippable protective covering from stainless steel panel prior to installation. 1.10( SITE CONDITIONS A.( Weather Limitations: Proceed with installation only when existing and forecasted weather conditions permit assembly of this Work to be performed according to...

Open the catalog to page 4
STAINLESS STEEL METAL PLATE - 5

PROJECT(NO.:( DATE:( PROJECT(NAME( PROJECT(LOCATION( Dynamic: Pass water penetration test under dynamic pressure of 6.24 psf in accordance with AAMA 501.1. Structural: Provide systems tested in accordance with ASTM E 330 and certified to be without permanent deformation or failure of structural members. ( 2.03( MATERIALS A.( Stainless Steel Plate: Alloy and temper as recommended by manufacturer for application and in compliance with manufacturers performance requirements. 1.( Stainless Steel Material: [Type 304] or [Type 316]. 2.( Thickness: [18 gage] or [22 gage]. 3.( Finish: No. 4 Bright...

Open the catalog to page 5
STAINLESS STEEL METAL PLATE - 6

PROJECT(NO.:( DATE:( PROJECT(NAME( PROJECT(LOCATION( G.( Weather Barriers: Provide climate specific weather barrier with performance characteristics for air penetration, water vapor transmission, and water penetration resistance. 1.( Refer to Section 07 2500 for requirements. PART 3(- EXECUTION 3.01( EXAMINATION A.( Examine substrates, and Work areas and conditions with Installer present for compliance with requirements for installation tolerances, wall panel supports, and other conditions affecting performance of this Work. B.( Examine wall framing to verify that girts, angles, channels,...

Open the catalog to page 6
STAINLESS STEEL METAL PLATE - 7

PROJECT(NO.:( DATE:( PROJECT(NAME( PROJECT(LOCATION( H.( Install weather tight escutcheons for pipe and conduit penetrating exterior walls. I.( Metal Protection: Where dissimilar metals will contact each other or corrosive substrates, protect against galvanic action as recommended by wall panel manufacturer. Install attachment system to support wall panels and with provisions to provide a complete weather tight wall system, including sub girts, extrusions, flashings and trim. 1.( Include attachment to supports and trims at locations using dissimilar materials. 2.( Do not apply sealants to...

Open the catalog to page 7