Painted Aluminum - 1

PROJECT NAME PROJECT LOCATION SECTION 07 4213.24 ALUMINUM METAL PLATE WALL PANELS Aluminum metal plate wall panels Section 06 1000 – Rough Carpentry: Plywood substrate wall sheathing. Section 07 2500 – Weather Barriers: Air and moisture barrier required as part of metal wall panel assembly. Section 07 6200 – Sheet Metal Flashing and Trim: Field formed flashings and other sheet metal work. Section 05 4000 – Cold-Formed Metal Framing: Wall panel substrates support framing. Section 07 9005 – Joint Sealers: Perimeter sealant. Metal Plate Wall Panel Assembly: Metal plate wall panels, attachment system components, miscellaneous metal framing, and accessories necessary for a complete weather tight wall system based on AAMA CW-RS-1. AAMA - American Architectural Manufacturers Association (www.aamanet.org) 1. AAMA CW-RS-1 – The Rain Screen Principle and Pressure Equalized Wall Design; 2004 2. AAMA 501.1 – Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure; 2005 3. AAMA 501.2 - Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems; 2009 4. AAMA 508 – Voluntary Test Method and Specification for Pressure Equalized Rain Screen Wall Cladding Systems; 2007 5. AAMA 611 - Voluntary Standards for Anodized Architectural Aluminum; 1998 6. AAMA 2605 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels; 2011 (Testing based on 2005 Edition) ASTM International (American Society for Testing and Materials; www.astm.org) 1. ASTM B 117 - Standard Practice for Operating Salt Spray (Fog) Apparatus; 2011 2. ASTM C 754 - Standard Specification for Installation of Steel Framing Members to Receive ScrewAttached Gypsum Panel Products; 2009 3. ASTM D 523 - Standard Test Method for Specular Gloss; 2008 4. ASTM D 2244 – Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates; 2011 5. ASTM D 2247 - Standard Practice for Testing Water Resistance of Coatings in 100% Relative Humidity; 2011 6. ASTM D 4214 - Standard Test Methods for Evaluating the Degree of Chalking of Exterior Paint Films; 2007 7. ASTM E 8/E 8M - Standard Test Methods for Tension Testing of Metallic Materials; 2009 8. ASTM E 283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen; 2004. 9. ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference; 2010 10. ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference; 2009 AUTHOR FILE NAME ALUMINUM METAL PLATE WALL PANELS 07 4213.24 - 1

Open the catalog to page 1
Painted Aluminum - 2

PROJECT NAME PROJECT LOCATION 11. ASTM E 1233 – Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Cyclic Air Pressure Differential; 2006 C. LEED – Leadership in Energy and Environmental Design NAAMM – National Association of Architectural Metal Manufacturers SMACNA – Sheet Metal and Air Conditioning Contractor’s National Association TAS - Testing Application Standards; Florida Building Code, 2007 1. TAS 202 – Criteria for Testing Impact and Non-Impact Resistant Building Envelope Components Using Uniform Static Air Pressure Loading;...

Open the catalog to page 2
Painted Aluminum - 3

PROJECT NAME PROJECT LOCATION Penetrations of wall by pipes and utilities. Test and Inspection Reports: Submit test and inspection reports on each type of wall panel system provided for project based on evaluation of comprehensive tests performed by qualified testing agency. Maintenance Data: Submit maintenance data for metal plate wall panels. Warranty: Submit manufacturer warranty and ensure forms have been completed in Owner's name and registered with manufacturer. Samples: Submit for each type of exposed finish required, and prepared on samples of size as follows: 1. Aluminum Metal...

Open the catalog to page 3
Painted Aluminum - 4

PROJECT NAME PROJECT LOCATION Do not store panels in contact with other materials that might cause staining, denting, or other surface damage. Provide storage of panels to ensure dryness, with positive slope for drainage of moisture. Remove strippable protective covering from aluminum panel prior to installation. Weather Limitations: Proceed with installation only when existing and forecasted weather conditions permit assembly of this Work to be performed according to manufacturer's installation instructions and warranty requirements. Field Measurements: Verify locations of structural...

Open the catalog to page 4
Painted Aluminum - 5

PROJECT NAME PROJECT LOCATION Design, fabricate, and erect a dry joint, pressure equalized rainscreen aluminum wall panel system without use of sealants, gaskets, or butyl tape, tested as installed in compliance with AAMA 508, and as follows. 1. Pressure Equalization Cycling: Pass cycled pressure loading from 5 psf to 25 psf for 100 three-second cycles at 0.08 seconds or less; ASTM E 1233. 2. Air Infiltration: 0.12 cfm per sf of wall area, tested at 1.57 psf (25 mph) in accordance with ASTM E 283. a. Maintain air/water barrier leakage rate at 0.11 to 0.13 cfm per sf at 1.57 psf when tested...

Open the catalog to page 5
Painted Aluminum - 6

PROJECT NAME PROJECT LOCATION Two-Coat Fluoropolymer: AAMA 2605, fluoropolymer finish containing not less than 70 percent PVDF resin by weight in color coat. Prepare, pre-treat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' installation instructions. Three-Coat Fluoropolymer: AAMA 2605, fluoropolymer finish containing not less than 70 percent PVDF resin by weight in both color coat and clear topcoat. Prepare, pre-treat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' installation instructions. Two-Coat...