Aluminum Metal Plate Wall Panels Specification Summary

General Overview:
This document specifies aluminum metal plate wall panels, detailing related requirements such as cold-formed metal framing, rough carpentry, weather barriers, sheet metal flashing and trim, and joint sealers. The assembly is a complete weather-tight system adhering to AAMA CW-RS-1 standards.

Reference Standards:
Includes AAMA guidelines for rain screen principles, water penetration, and quality assurance, alongside ASTM standards for salt spray, gloss, color tolerance, water resistance, and structural performance. Additional references include TAS, LEED, NAAMM, SMACNA, and NIST standards.

Administrative Requirements:
Coordination with other construction elements is essential. A preinstallation meeting with stakeholders is required to review schedules, materials, and installation methods. Necessary submittals include product data, shop drawings, samples, test reports, maintenance data, and warranties.

Quality Assurance:
Manufacturers and installers must have a minimum of five years of experience. Mockups are required to verify selections and demonstrate quality standards. Guidelines for delivery, storage, and handling ensure proper protection and storage of materials.

Site Conditions:
Installation should only occur under suitable weather conditions, with field measurements verified before fabrication.

Warranty:
Warranties cover manufacturing defects and finish deterioration, including structural failures, color retention, chalking, adhesion, gloss retention, and resistance to salt spray and humidity.

Products:
The specified manufacturer is Dri-Design, with performance requirements for pressure equalization, air infiltration, water penetration, and structural integrity. Materials include aluminum plate with specified thickness, weight, and finish options. Fabrication must meet performance requirements and include welded inside corners.

Specifications:
Outlines specifications for aluminum metal plate wall panels, including post-finishing requirements and compliance with NAAMM's Metal Finishes Manual. Specifies the use of a Superior Performance Organic Coating System, AAMA 2605, with fluoropolymer finishes containing at least 70% PVDF resin by weight. Anodized finishes must comply with AAMA 611 standards.

Procedures:
Installation involves examining substrates and conditions, preparing miscellaneous framing, and installing wall panels per manufacturer's instructions. Panels should be installed using a progressive interlocking method, ensuring provisions for thermal and structural movement. Flashing and trim must comply with SMACNA standards.

Standards and Recommendations:
Recommends using field touch-up materials as advised by the coating manufacturer and specifies stainless steel fasteners for aluminum wall panels. Outlines requirements for weather barriers, sealants, and accessories to ensure a complete and weather-tight assembly.

Field Quality Control:
A qualified independent testing agency should perform field tests and inspections, including a water-spray test per AAMA 501.2. Non-compliant panels must be replaced, with additional tests conducted at the contractor's expense.

Cleaning and Protection:
After installation, panels should be cleaned as recommended by the manufacturer, with weep holes and drainage channels cleared of obstructions. Installed products must be protected from damage during subsequent construction, with damaged panels replaced if necessary.
See more

Catalog excerpts

Painted Aluminum-1

PROJECT NAME PROJECT LOCATION SECTION 07 4213.24 ALUMINUM METAL PLATE WALL PANELS Aluminum metal plate wall panels Section 06 1000 – Rough Carpentry: Plywood substrate wall sheathing. Section 07 2500 – Weather Barriers: Air and moisture barrier required as part of metal wall panel assembly. Section 07 6200 – Sheet Metal Flashing and Trim: Field formed flashings and other sheet metal work. Section 05 4000 – Cold-Formed Metal Framing: Wall panel substrates support framing. Section 07 9005 – Joint Sealers: Perimeter sealant. Metal Plate Wall Panel Assembly: Metal plate wall panels, attachment system components, miscellaneous metal framing, and accessories necessary for a complete weather tight wall system based on AAMA CW-RS-1. AAMA - American Architectural Manufacturers Association (www.aamanet.org) 1. AAMA CW-RS-1 – The Rain Screen Principle and Pressure Equalized Wall Design; 2004 2. AAMA 501.1 – Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure; 2005 3. AAMA 501.2 - Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems; 2009 4. AAMA 508 – Voluntary Test Method and Specification for Pressure Equalized Rain Screen Wall Cladding Systems; 2007 5. AAMA 611 - Voluntary Standards for Anodized Architectural Aluminum; 1998 6. AAMA 2605 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels; 2011 (Testing based on 2005 Edition) ASTM International (American Society for Testing and Materials; www.astm.org) 1. ASTM B 117 - Standard Practice for Operating Salt Spray (Fog) Apparatus; 2011 2. ASTM C 754 - Standard Specification for Installation of Steel Framing Members to Receive ScrewAttached Gypsum Panel Products; 2009 3. ASTM D 523 - Standard Test Method for Specular Gloss; 2008 4. ASTM D 2244 – Standard Practice for Calculation of Color Tolerances and Color Differences from Instrumentally Measured Color Coordinates; 2011 5. ASTM D 2247 - Standard Practice for Testing Water Resistance of Coatings in 100% Relative Humidity; 2011 6. ASTM D 4214 - Standard Test Methods for Evaluating the Degree of Chalking of Exterior Paint Films; 2007 7. ASTM E 8/E 8M - Standard Test Methods for Tension Testing of Metallic Materials; 2009 8. ASTM E 283 - Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen; 2004. 9. ASTM E 330 - Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference; 2010 10. ASTM E 331 - Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference; 2009 AUTHOR FILE NAME ALUMINUM METAL PLATE WALL PANELS 07 4213.24 - 1

 Open the catalog to page 1
Painted Aluminum-2

PROJECT NAME PROJECT LOCATION 11. ASTM E 1233 – Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Cyclic Air Pressure Differential; 2006 C. LEED – Leadership in Energy and Environmental Design NAAMM – National Association of Architectural Metal Manufacturers SMACNA – Sheet Metal and Air Conditioning Contractor’s National Association TAS - Testing Application Standards; Florida Building Code, 2007 1. TAS 202 – Criteria for Testing Impact and Non-Impact Resistant Building Envelope Components Using Uniform Static Air Pressure Loading; 1994...

 Open the catalog to page 2
Painted Aluminum-3

PROJECT NAME PROJECT LOCATION Penetrations of wall by pipes and utilities. Test and Inspection Reports: Submit test and inspection reports on each type of wall panel system provided for project based on evaluation of comprehensive tests performed by qualified testing agency. Maintenance Data: Submit maintenance data for metal plate wall panels. Warranty: Submit manufacturer warranty and ensure forms have been completed in Owner's name and registered with manufacturer. Samples: Submit for each type of exposed finish required, and prepared on samples of size as follows: 1. Aluminum Metal Plate...

 Open the catalog to page 3
Painted Aluminum-4

PROJECT NAME PROJECT LOCATION Do not store panels in contact with other materials that might cause staining, denting, or other surface damage. Provide storage of panels to ensure dryness, with positive slope for drainage of moisture. Remove strippable protective covering from aluminum panel prior to installation. Weather Limitations: Proceed with installation only when existing and forecasted weather conditions permit assembly of this Work to be performed according to manufacturer's installation instructions and warranty requirements. Field Measurements: Verify locations of structural members...

 Open the catalog to page 4
Painted Aluminum-5

PROJECT NAME PROJECT LOCATION Design, fabricate, and erect a dry joint, pressure equalized rainscreen aluminum wall panel system without use of sealants, gaskets, or butyl tape, tested as installed in compliance with AAMA 508, and as follows. 1. Pressure Equalization Cycling: Pass cycled pressure loading from 5 psf to 25 psf for 100 three-second cycles at 0.08 seconds or less; ASTM E 1233. 2. Air Infiltration: 0.12 cfm per sf of wall area, tested at 1.57 psf (25 mph) in accordance with ASTM E 283. a. Maintain air/water barrier leakage rate at 0.11 to 0.13 cfm per sf at 1.57 psf when tested in...

 Open the catalog to page 5
Painted Aluminum-6

PROJECT NAME PROJECT LOCATION Two-Coat Fluoropolymer: AAMA 2605, fluoropolymer finish containing not less than 70 percent PVDF resin by weight in color coat. Prepare, pre-treat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' installation instructions. Three-Coat Fluoropolymer: AAMA 2605, fluoropolymer finish containing not less than 70 percent PVDF resin by weight in both color coat and clear topcoat. Prepare, pre-treat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' installation instructions. Two-Coat Mica...