System Zero
11Pages

{{requestButtons}}

Catalog excerpts

System Zero - 1

Zero restrictions. Zero waste. Glen Dimplex Thermal Solutions has achieved a revolution in temperature management for commercial and industrial applications. With System Zero we present a heating-cooling system which is simply versatile – because System Zero is the only heat pump with zero restrictions when it comes to the choice of heat source: whether outside air, geothermal energy or waste heat from cooling systems... At the same time, System Zero makes saving money radically simple – because only System Zero offers zero waste: valuable energy, squandered in the past, is now put to profitable use. See for yourself what System Zero can do! Cooling. Heating. Ventilation. Glen Dimplex Thermal Solutions System Zero. A revolution in heat pumps for trade and industry

Open the catalog to page 1
System Zero - 2

System Zero... Zero  restrictions. Outside air? Waste heat? Geothermal energy? With System Zero you can use whatever combination of freely available heat sources is best suited to your purpose. In the warehouse, data centre or block of flats, System Zero always does the job. ... meets System Zero. Zero waste. Is the waste heat from your cooling system going to waste? With System Zero you can stop your money going up in smoke and start tapping into a valuable, hitherto unused source of energy. System Zero cuts your energy costs – by up to 25%

Open the catalog to page 2
System Zero - 3

The new heat pump system for commercial and industrial clients. System Zero is here. Air outlet side Air intake side There’s a new force in heat pumps for commercial and industrial applications: System Zero. Forget “either/or” – System Zero is the first series-produced heat pump to combine various heat sources, including waste heat, and regulate them for maximum efficiency. All while running on the environmentally friendly cooling agent propane. The result? Zero energy wasted, and zero money wasted. That makes System Zero a highly flexible all-purpose solution for a huge range of...

Open the catalog to page 3
System Zero - 4

Heat source Geothermal energy Heat source Waste heat Simple and cheap to access Efficiency and performance decreases as outside temperature falls Constant source temperature all year round Expensive to access due to space requirements, excavation work and/or drilling Freely available “waste product” from many different processes (e.g. cooling) 1: uilding’s heating requirements, B depending on outside temperature 2: Heat output from air, 1 compressor 3: Heat output for air, 2 compressors 4: Switch point air to brine 5: Heat output brine, 2 compressors Volume and continuity can sometimes be...

Open the catalog to page 4
System Zero - 5

The heroes of the refrigeration circuit. Maik Heydrich and his team: in the beginning was the idea. Six months later came the revolution in heating and cooling. The three GDTS engineers behind the System Zero success story: Maik Heydrich (main image), Uwe Steeger (above, left), Dieter Müller (above, right) How we came up with System Zero. It was a cold, rainy October day in 2012. Maik Heydrich was on his way back home from his 220th customer visit. To date he had developed 220 different tailor-made models for cooling computer centres, or used geothermal energy to heat whole apartment...

Open the catalog to page 5
System Zero - 6

System Zero is here. Zero waste heat wasted. Zero cost explosions. Waste heat isn’t wasted any more – in fact it helps save costs for heating and cooling. System Zero. “You can’t make an omelette without breaking eggs,” goes the old proverb. And if you’re heating or cooling, you’re wasting valuable energy. Whether it’s a computer centre, cold store or apartment complex, large buildings and commercial and industrial facilities produce a lot of waste heat. That’s hardly to be avoided, given the laws of physics. But does the energy really have to go to waste? That was the question that led a...

Open the catalog to page 6
System Zero - 7

Warehouse of a restaurant chain: heating from cooling units. System Zero System Zero Heating and cooling for offices or warehouse space 1 Heat source: waste heat 2 Heat source: external air 3 Optional heat source: geothermal energy (or other waste heat sources) The situation Large warehouses and distribution facilities, belonging to restaurant chains or online vendors, for example, have year-round cooling for meat, milk and fresh fruit. This produces plenty of waste heat, which in the past largely went unused (approximately 657 MWh/year for 100 kW of cooling). The idea Use waste heat to...

Open the catalog to page 7
System Zero - 8

Computer centre: heating with server coolers. Apartment blocks or luxury villas: plenty of heating, minimal costs. saved per year in heating costs* Heating and cooling for offices Heat source: external air System Zero System Zero Heat source: waste heat 3 Optional heat source: geothermal energy (or other waste heat sources) System Zero 1 Heating and cooling for the building Heat source: external air Heat source: geothermal energy The idea Use waste heat to heat and cool the entire office complex. The situation Millions of gigabytes of data are processed and stored in computer centres, with...

Open the catalog to page 8
System Zero - 9

System Zero. Technical data: A hot-water heat pump is an efficient solution for hot water in both new and old buildings. It can supply all the hot water needed by a family home all year round, independently of the heating system. It draws up to 70% of the energy it needs for producing hot water from the ambient air or the waste heat present in the air inside the building. A particular plus is that it can store an extralarge amount of photovoltaic electricity and use it to increase self-consumption as and when necessary. System Zero Propan System Zero Heat sources reversible with mode for 2...

Open the catalog to page 9
System Zero - 10

Our services for your System Zero. Every System Zero is put together individually. Our experts know exactly what they are doing. Analysis & consulting We start by visiting the site to see what you really need and what the best technical options are for you. Implementation & installation We take care of coordinating the various specialists, making sure you get the right pipes and the right connectivity. Our experienced installation team then starts the system up. www.gdts.one/system-zero Service As well as annual maintenance, System Zero comes with a monitoring system that ensures...

Open the catalog to page 10

All Dimplex catalogs and technical brochures

  1. LA 40TU-2

    5 Pages

  2. LA 0712BW

    2 Pages

  3. LA 0712BWC

    2 Pages

  4. LA 3860

    2 Pages

  5. Heat pump

    34 Pages

  6. SI 90TU

    6 Pages

  7. SI 22TU

    6 Pages

  8. LI 24TES

    10 Pages

  9. DHW 300

    2 Pages

  10. LA 60S-TU(R)

    4 Pages

  11. M Flex Air

    2 Pages

  12. M Flex

    6 Pages

  13. System C.

    9 Pages

  14. Plus Magazine

    100 Pages

  15. LIK12TU

    2 Pages

  16. System M.

    2 Pages

  17. System M

    15 Pages

  18. DHW 400+.

    2 Pages

  19. Splydro

    2 Pages

  20. Heat Pumps

    15 Pages

  21. NEWS 2013

    11 Pages

Archived catalogs

  1. Product range

    118 Pages