Introduction
SmartRad fan convectors offer an energy-efficient solution for heating and cooling, particularly suitable for older buildings. They provide high heat output and cooling capacity with a sophisticated design, making them an ideal choice for modernizing existing systems.

Specifications
SmartRad fan convectors are designed for both heating and cooling applications. They feature automatic regulation of three fan levels based on heating and cooling needs, with a maximum fan level that can be preset. The system automatically switches off at flow temperatures below 25°C for heating and above 20°C for cooling. The maximum permissible flow temperature is 85°C, and the heating connection can be on either the left or right side.

Electronic Room Temperature Control
The integrated electronic thermostat allows users to set the desired room temperature. The convector adjusts the fan levels automatically to reach the set temperature, switching to the highest fan level if there is a significant difference between the room and set temperatures. As the room temperature approaches the set temperature, the airflow is reduced in stages and switches off automatically once the desired temperature is reached. The maximum fan level can be manually preset to avoid high fan levels in sensitive areas like bedrooms.

Technical Data
The SRX 120CM fan convectors come in three models: SRX 070CM, SRX 120CM, and SRX 160CM. Each model has different heat outputs at various temperatures and cooling capacities. The sound pressure level at a distance of 1m is consistent across models, ranging from 27 to 47 dB(A). Dimensions vary slightly between models, with the width ranging from 503mm to 911mm.

Programming Modules
Optional programming modules such as RMT 2, RX TI 24, RX PW 1, and RX TI RB allow for customized heating or cooling schedules based on user habits. These modules are particularly useful in environments with multiple convectors, like offices.

Contact Information
For more information, Glen Dimplex Deutschland GmbH and Glen Dimplex Austria GmbH can be contacted through their respective websites and contact details provided in the document.

Note: Specifications are subject to change and errors.
See more

Catalog excerpts

SmartRad fan convectors for heating and cooling-1

SmartRad fan convectors for heating and cooling SmartRad fan convectors Conventional convectors and radiators need relatively high flow High heat output and cooling capacity with a sophisticated design temperatures to provide good heating coverage and do not Fan convectors have a specially designed heat exchanger consume energy as efficiently as they could. Panel heating which is ideal for heating living spaces in an energy-efficient systems, for example underfloor heating, can help to save manner when combined with low temperature heating systems energy and heating costs as they are operated at low flow in an older building. The low-noise fans distribute heat evenly to temperatures. However, panel heating is expensive and difficult warm the room for optimum comfort. When installed with a to engineer when renovating old buildings or upgrading an reversible heat pump this convector can be used for cooling existing system. and ensures that the desired temperature is reached quickly with its powerful energy output. The new SmartRad series for heating and cooling combines a sophisticated design with advanced technology.

 Open the catalog to page 1
SmartRad fan convectors for heating and cooling-2

SmartRad fan convectors SRX...CM Suitable for heating and cooling Automatic regulation of three fan levels depending on heating and cooling requirements. The maximum fan level can be preset. Automatic switch-off at flow temperatures of less than 25°C in heating or higher than 20°C in cooling operation Maximum permissible flow temperature 85 °C Heating connection optionally on the left or right Electronic room temperature control/optional programming module The desired room temperature can be set using the integrated electronic thermostat. The convector's electronics compares the set temperature...

 Open the catalog to page 2

All Dimplex, Geschäftsbereich der Glen Dimplex Deutsch catalogs and technical brochures

  1. LA 40TU-2

    5  Pages

  2. LA 0712BW

    2  Pages

  3. LA 3860

    2  Pages

  4. SI 90TU

    6  Pages

  5. M Flex

    6  Pages

Archived catalogs

  1. DHW 300

    2  Pages

  2. LA 60S-TU(R)

    4  Pages

  3. SI 22TU

    6  Pages

  4. Heat pump

    34  Pages

  5. LI 24TES

    10  Pages

  6. LA 0712BWC

    2  Pages

  7. LIK12TU

    2  Pages

  8. System M.

    2  Pages

  9. Plus Magazine

    100  Pages

  10. System M

    15  Pages

  11. Splydro

    2  Pages

  12. Heat Pumps

    15  Pages

  13. System C.

    9  Pages

  14. System Zero

    11  Pages

  15. DHW 400+.

    2  Pages

  16. M Flex Air

    2  Pages

  17. NEWS 2013

    11  Pages

  18. Product range

    118  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.