Product Range Overview 2013 Renewable Energies Heat Pumps Solar Thermal Systems Domestic Heating Products Solar Thermal Systems Domestic Heating Systems
Open the catalog to page 1Air-to-water heat pump for outdoor installation High-efficiency air-to-water heat pump package solution Heating and domestic hot water preparation package Max. flow temperature 60°C Casing colour White aluminium (similar to RAL 9006) Heat pump and HWK 332 Econ-E Hydro Tower The Hydro Tower with integrated WPM EconPlus regulation enables the fast and simple connection of a high-efficiency air-to-water heat pump installed outdoors to a heating system with an unmixed heating circuit. The following components are mounted in a space-saving way and wired ready to use. • Switchable pipe heater (2/4/6...
Open the catalog to page 3Air-to-water heat pump for outdoor installation High-efficiency air-to-water heat pump High-efficiency air-to-water heat pump Max. flow temperature 60°C Casing colour White aluminium (similar to RAL 9006) For installation close to walls Heat pump for heating purposes for outdoor installation with wall-mounted WPM EconPlus heat pump manager. Sound-optimised through the use of slow-running ‚owl‘s wing‘ EC fans with a low natural sounding noise, an encapsulated compressor housing with swivelling compressor baseplate for solid-borne sound insulation. High coefficients of performance (COP) through...
Open the catalog to page 4Air-to-water heat pump for outdoor installation High-efficiency air-to-water heat pump Max. flow temperature 58°C Casing colour White aluminium (similar to RAL 9006) With two performance levels Heat pump for heating purposes for outdoor installation, with wall-mounted WPM EconPlus heat pump manager and two compressors for output reduction when operating at partial load. Sound-optimised through the use of slow-running ‚owl‘s wing‘ ventilators with a low natural sounding noise, an encapsulated compressor housing with free-swinging compressor baseplate for solid-borne sound insulation. High coefficients...
Open the catalog to page 5Air-to-water heat pump for outdoor installation Reversible high-efficiency air-to-water heat pump Max. flow temperature 60°C Flow temperature cooling min. 9°C Casing colour White aluminium (similar to RAL 9006) Optimised for heating and cooling Heat pump for heating and cooling purposes for outdoor installation with wall-mounted heat pump manager and two compressors for output reduction when operating at partial load. Sound-optimised by electronically controlled fans and an encapsulated compressor housing with free-swinging compressor baseplate for solid-borne sound insulation. High coefficients...
Open the catalog to page 6Air-to-water heat pump for outdoor installation Weather-proof protective cover for LA...TU air-to-water heat pumps Design weather-proof protective cover for retrofitting high-efficiency air-to-water heat pumps; required for uncovered outdoor installation, when the air intake or the air outlet side is exposed to strong winds. Order reference Width x Height x Depth mm Pipe assembly for LA...TU air-to-water heat pumps For connection from the side The pipe assembly, which can be screwed directly into the heat pump, consists of two specially bent pipework, which are also adapted to the high efficiency...
Open the catalog to page 7Air-to-water heat pump for outdoor installation Air-to-water heat pump in split design Splydro split air-to-water heat pump Max. flow temperature 55°C Casing colour White Heating, cooling and domestic hot water preparation Heat pump for heating and cooling with hydraulic unit (indoors) – and outdoor unit, which are connected via a refrigerant pipe (special accessory). The outdoor unit with output-controlled compressor (inverter) adapts the heat output to the heating consumption of the building and can be installed close to the wall. The electrical connection between the indoor and outdoor unit...
Open the catalog to page 8Air-to-water heat pump for outdoor installation Reference room controller Smart RTC (RoomTemperatureController) with humidity sensor The reference room controller measures the temperature difference between the actual room temperature and the set temperature, and communicates this to the heat pump manager. The return set temperature is calculated on the basis of this difference. The ~230 V voltage supply (2-core) and the bus cable (2-core, screened) must be provided by the customer. Additional functions: - ‚Operating mode‘ button – switches between automatic and summer operating mode - ‚Rapid...
Open the catalog to page 9Air-to-water heat pump for outdoor installation Low temperature air-to-water heat pump Low temperature air-to-water heat pump Max. flow temperature 55°C Casing colour White aluminium (similar to RAL 9006) For installation close to walls Air-to-water heat pump for outdoor installation with outside temperature controlled WPM 2006 plus heat pump manager. Sound-optimised through the use of low-noise ‚owl‘s wings‘ ventilator blades. Energy-efficient defrosting by reverse circulation. High coefficients of performance (COP) thanks to compliance with EN 14511 for larger volume flows on the heat consumption...
Open the catalog to page 10Air-to-water heat pump for outdoor installation Air-to-water heat pump – higher flow temperature Medium temperature air-to-water heat pump Max. flow temperature 65°C Casing colour White aluminium (similar to RAL 9006) Medium temperature air-to-water heat pump for outdoor installation with outside temperature controlled WPM 2006 plus heat pump manager. Sound-optimised through the use of noise-reducing crescent wing axial fans and air deflector hoods; energy-efficient hot gas defrosting for optimum operation in combination with radiators. Universal design with optional domestic hot water preparation...
Open the catalog to page 11Air-to-water heat pump for outdoor installation Special accessories for air-to-water heat pumps for outdoor installation Electric connection line heat pump – heat pump manager Control cable between heat pump manager and the air-to-water heat pump for outdoor installation. Ready for connection with coded plug connections on both ends for laying in a protection tube (diameter at least 70 mm, confusion-proof: round plug for connection to the heat pump). Order reference EVL 996-1 Laying should take place separately from the mains cable. An extension of the control cable on-site is not permitted and...
Open the catalog to page 122 Pages
4 Pages
6 Pages
34 Pages
10 Pages
36 Pages
2 Pages
2 Pages
2 Pages
2 Pages
28 Pages
100 Pages
15 Pages
25 Pages
4 Pages
5 Pages
6 Pages
2 Pages
2 Pages
2 Pages
15 Pages
77 Pages
9 Pages
2 Pages
11 Pages
11 Pages
2 Pages
2 Pages
31 Pages
11 Pages
40 Pages
7 Pages
2 Pages
118 Pages