1. Catalogs
  2. Dimplex, Geschäftsbereich der Glen Dimplex Deutsch
  3. The latest innovations for 2009 - Renewable Energies

The latest innovations for 2009 - Renewable Energies
1 /16Pages

The latest innovations for 2009 - Renewable Energies

The latest innovations for 2009 - Renewable Energies
1 /16Pages

Catalog excerpts

The latest innovations for 2009 - Renewable Energies-1

Optimal integration Innovative heating & cooling Intelligent controls Effi cient combinations

 Open the catalog to page 1
The latest innovations for 2009 - Renewable Energies-2

The last six months, in particular, have made a lot of house-owners do some hard thinking. First came the record prices for heating oil in summer 2008, then the gas dispute between Russia and the Ukraine at the turn of the year. At times like these, home and building owners wish for nothing as strongly as reliable supplies and foreseeable costs for heating and hot water supplies. An ideal combination of different systems As a system provider in the renewable energy sector, Dimplex stands for a well-fi lled range covering all requirements for new buildings and heating modernisation projects. Above...

 Open the catalog to page 2
The latest innovations for 2009 - Renewable Energies-3

WPM EconPlus – the intelligent control system The heat pump manager controls the heat pump heating system and monitors the safety units of the refrigerating circuit. It provides all the functions of a modern heating regulation system. The sensors integrated into the highly effi cient air-to-water heat pumps for outdoor installation optimise heating and cooling and allow separate thermal energy metering for heating and domestic hot water preparation. Available as an accessory, the master controller for parallel connection allows the central control of up to 14 heat pumps. Even connections to Ethernet...

 Open the catalog to page 3
The latest innovations for 2009 - Renewable Energies-4

4 Universally applicable to-water heat pumps for outdoor installation LA 35TUR+ air-to-water heat pump for heating and cooling • Product series can be used up to a heat consumption of approx. 40 kW: LA 9TU, LA 12TU, LA 17TU, LA 25TU, LA 40TU • “Owl’s wing” ventilator blades produce a natural-sounding noise • High COPs due to high-performance evaporator Encapsulated compressor housing with solid-borne sound insulation for low noise emissions Hydraulic connections can be led out of the heat pump either downwards or to the side (special accessory). 17TU, LA 25TU and LA 40TU with two performance...

 Open the catalog to page 4
The latest innovations for 2009 - Renewable Energies-5

5 • Heat pump managers for high-effi ciency air-to-water heat pumps installed outdoors • Pressure sensors in the refrigerating circuit for optimised heating and cooling operation • Integrated thermal energy meter • Can be extended by additional modules (Ethernet, KNX/EIB, ...) • Simplifi ed connection via separate terminal blocks for 24 V and 230 V • WPM EconR for reversible heat pumps for heating and cooling Indoor installation (white) performance levels for modulating operation Space-saving design – no air ducts required on the inlet side temperature up to a maximum of 58 °C Eligible for subsidies...

 Open the catalog to page 5
The latest innovations for 2009 - Renewable Energies-6

The European Installation Bus (EIB) makes it possible to control heating systems as well as locking and alarm systems, lighting and blinds. The EIB additionally allows the remote monitoring and control of the heat generator. EIB is currently being installed mainly in new resident ial and commercial buildings, but it can also be integrated when old buildings are modernised. The EWPM additional module KNX/EIB is the interface for connecting a heat pump manager to building management technology. NWPM additional module acts as an interface between the heat manager and an Ethernet network for the...

 Open the catalog to page 6
The latest innovations for 2009 - Renewable Energies-7

• WMZ 25 can be used for a volume fl ow of up to 2.5 m3/h • WMZ 32 can be used for a volume fl ow of up to 5.0 m3/h • Wear-free fl ow metering via Kármán vortex street with low pressure losses • Immersion sensor for highly accurate measurement • Determining separate thermal energy volumes for heating and DHW preparation and display on the heat pump manager • Wired ready for assembly in the hot water distribution system Software update via SmartKey (special accessory) is necessary! The DDV has the following advantages: • Hot water fl ow is guaranteed in all operating conditions • Energy savings...

 Open the catalog to page 7
The latest innovations for 2009 - Renewable Energies-8

8 • The waste heat (20 °C) contained in the indoor air is used for domestic water preparation Operating limit from 15 °C to 35 °C for installation in living quarters Water temperature can be set from 23 °C to 60 °C Heat-up time from 15 °C to 45 °C: 7.6 h 125 outgoing air stubs for optimum connection to exhaust air systems Volume fl ow: 140 m3/h (ventilator runs either permanently or only during hot water heating) • Quiet operation • Min. installation dimension of 60 cm allows covering with a front panel Dimplex fan convectors, with their active air circulation, can reduce heating costs in comparison...

 Open the catalog to page 8
The latest innovations for 2009 - Renewable Energies-9

9 Solar radiation is collected reliably and effi ciently by the solar collectors, and is then used for heating the transfer medium. The collector design (meander version with collection manifold) is suitable for both small and larger collector surfaces. Compact domestic hot water preparation is thus possible in addition to effi cient supplementary heating with a larger collector surface. Depending on the local requirements, the collectors can be mounted horizontally or vertically onto the roof. Accessory packages for free-standing installation and mounting on fl at roofs are also available. •...

 Open the catalog to page 9
The latest innovations for 2009 - Renewable Energies-10

10 • Successor to the previous ZL 270 series • Maximum volume fl ow 300m3/h (control levels programmable in the range 50 – 300 m3/h) • Various control panels are available for switching the fan levels (wireless, fl ush-mounted/surface-mounted) • Automatic summer bypass with adjustable switching temperature for interrupting heat recovery in summer • CO2 sensor and humidity sensor can be connected optionally for ventilator control according to need • Degree of recovery approx. 90% • Automatic defrosting ZL 300 central ventilation device with heat recovery Succ Max th Vario wire Auto in vent Deg...

 Open the catalog to page 10
The latest innovations for 2009 - Renewable Energies-11

11 DXL 200 • Volume fl ow 110 m3/h • For use in WCs, bathrooms, etc. DXL 200EC • Volume fl ow 110 m3/h • For use in WCs, bathrooms, etc. • With additional humidity control / hygrostat and EC motor • Run-down control settable up to 20 minutes Volume fl ow 80 m3/h • For use in WCs, bathrooms, etc. • DXL 100H: with additional hygrostat for ventilation control according to need • DXL 100T: with additional, adjustable hygrostat and run-down relay GXL 6 • Max. volume fl ow 270 m3/h • One control level, switchable via a standard ON/OFF switch GXL 9 • Max. volume fl ow 730 m3/h • Two control levels and...

 Open the catalog to page 11

All Dimplex, Geschäftsbereich der Glen Dimplex Deutsch catalogs and technical brochures

  1. LA 40TU-2

    5  Pages

  2. LA 0712BW

    2  Pages

  3. LA 3860

    2  Pages

  4. SI 90TU

    6  Pages

  5. M Flex

    6  Pages

Archived catalogs

  1. DHW 300

    2  Pages

  2. LA 60S-TU(R)

    4  Pages

  3. SI 22TU

    6  Pages

  4. Heat pump

    34  Pages

  5. LI 24TES

    10  Pages

  6. LA 0712BWC

    2  Pages

  7. LIK12TU

    2  Pages

  8. System M.

    2  Pages

  9. Plus Magazine

    100  Pages

  10. System M

    15  Pages

  11. Splydro

    2  Pages

  12. Heat Pumps

    15  Pages

  13. System C.

    9  Pages

  14. System Zero

    11  Pages

  15. DHW 400+.

    2  Pages

  16. M Flex Air

    2  Pages

  17. NEWS 2013

    11  Pages

  18. Product range

    118  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.