Catalog excerpts
Optimal integration Innovative heating & cooling Intelligent controls Effi cient combinations
Open the catalog to page 1The last six months, in particular, have made a lot of house-owners do some hard thinking. First came the record prices for heating oil in summer 2008, then the gas dispute between Russia and the Ukraine at the turn of the year. At times like these, home and building owners wish for nothing as strongly as reliable supplies and foreseeable costs for heating and hot water supplies. An ideal combination of different systems As a system provider in the renewable energy sector, Dimplex stands for a well-fi lled range covering all requirements for new buildings and heating modernisation projects....
Open the catalog to page 2WPM EconPlus – the intelligent control system The heat pump manager controls the heat pump heating system and monitors the safety units of the refrigerating circuit. It provides all the functions of a modern heating regulation system. The sensors integrated into the highly effi cient air-to-water heat pumps for outdoor installation optimise heating and cooling and allow separate thermal energy metering for heating and domestic hot water preparation. Available as an accessory, the master controller for parallel connection allows the central control of up to 14 heat pumps. Even connections to...
Open the catalog to page 34 Universally applicable to-water heat pumps for outdoor installation LA 35TUR+ air-to-water heat pump for heating and cooling • Product series can be used up to a heat consumption of approx. 40 kW: LA 9TU, LA 12TU, LA 17TU, LA 25TU, LA 40TU • “Owl’s wing” ventilator blades produce a natural-sounding noise • High COPs due to high-performance evaporator Encapsulated compressor housing with solid-borne sound insulation for low noise emissions Hydraulic connections can be led out of the heat pump either downwards or to the side (special accessory). 17TU, LA 25TU and LA 40TU with two...
Open the catalog to page 45 • Heat pump managers for high-effi ciency air-to-water heat pumps installed outdoors • Pressure sensors in the refrigerating circuit for optimised heating and cooling operation • Integrated thermal energy meter • Can be extended by additional modules (Ethernet, KNX/EIB, ...) • Simplifi ed connection via separate terminal blocks for 24 V and 230 V • WPM EconR for reversible heat pumps for heating and cooling Indoor installation (white) performance levels for modulating operation Space-saving design – no air ducts required on the inlet side temperature up to a maximum of 58 °C Eligible for...
Open the catalog to page 5The European Installation Bus (EIB) makes it possible to control heating systems as well as locking and alarm systems, lighting and blinds. The EIB additionally allows the remote monitoring and control of the heat generator. EIB is currently being installed mainly in new resident ial and commercial buildings, but it can also be integrated when old buildings are modernised. The EWPM additional module KNX/EIB is the interface for connecting a heat pump manager to building management technology. NWPM additional module acts as an interface between the heat manager and an Ethernet network for...
Open the catalog to page 6• WMZ 25 can be used for a volume fl ow of up to 2.5 m3/h • WMZ 32 can be used for a volume fl ow of up to 5.0 m3/h • Wear-free fl ow metering via Kármán vortex street with low pressure losses • Immersion sensor for highly accurate measurement • Determining separate thermal energy volumes for heating and DHW preparation and display on the heat pump manager • Wired ready for assembly in the hot water distribution system Software update via SmartKey (special accessory) is necessary! The DDV has the following advantages: • Hot water fl ow is guaranteed in all operating conditions • Energy...
Open the catalog to page 78 • The waste heat (20 °C) contained in the indoor air is used for domestic water preparation Operating limit from 15 °C to 35 °C for installation in living quarters Water temperature can be set from 23 °C to 60 °C Heat-up time from 15 °C to 45 °C: 7.6 h 125 outgoing air stubs for optimum connection to exhaust air systems Volume fl ow: 140 m3/h (ventilator runs either permanently or only during hot water heating) • Quiet operation • Min. installation dimension of 60 cm allows covering with a front panel Dimplex fan convectors, with their active air circulation, can reduce heating costs in...
Open the catalog to page 89 Solar radiation is collected reliably and effi ciently by the solar collectors, and is then used for heating the transfer medium. The collector design (meander version with collection manifold) is suitable for both small and larger collector surfaces. Compact domestic hot water preparation is thus possible in addition to effi cient supplementary heating with a larger collector surface. Depending on the local requirements, the collectors can be mounted horizontally or vertically onto the roof. Accessory packages for free-standing installation and mounting on fl at roofs are also available....
Open the catalog to page 910 • Successor to the previous ZL 270 series • Maximum volume fl ow 300m3/h (control levels programmable in the range 50 – 300 m3/h) • Various control panels are available for switching the fan levels (wireless, fl ush-mounted/surface-mounted) • Automatic summer bypass with adjustable switching temperature for interrupting heat recovery in summer • CO2 sensor and humidity sensor can be connected optionally for ventilator control according to need • Degree of recovery approx. 90% • Automatic defrosting ZL 300 central ventilation device with heat recovery Succ Max th Vario wire Auto in vent...
Open the catalog to page 1011 DXL 200 • Volume fl ow 110 m3/h • For use in WCs, bathrooms, etc. DXL 200EC • Volume fl ow 110 m3/h • For use in WCs, bathrooms, etc. • With additional humidity control / hygrostat and EC motor • Run-down control settable up to 20 minutes Volume fl ow 80 m3/h • For use in WCs, bathrooms, etc. • DXL 100H: with additional hygrostat for ventilation control according to need • DXL 100T: with additional, adjustable hygrostat and run-down relay GXL 6 • Max. volume fl ow 270 m3/h • One control level, switchable via a standard ON/OFF switch GXL 9 • Max. volume fl ow 730 m3/h • Two control levels...
Open the catalog to page 11All Dimplex catalogs and technical brochures
-
LA 40TU-2
5 Pages
-
LA 0712BW
2 Pages
-
LA 0712BWC
2 Pages
-
LA 3860
2 Pages
-
Heat pump
34 Pages
-
Highlight brochure 2023
36 Pages
-
SI 90TU
6 Pages
-
SI 22TU
6 Pages
-
LI 24TES
10 Pages
-
DHW 300
2 Pages
-
LA 60S-TU(R)
4 Pages
-
M Flex Air
2 Pages
-
M Flex
6 Pages
-
Domestic hot water
28 Pages
-
System C.
9 Pages
-
Plus Magazine
100 Pages
-
SI 35TUR/SI 70TUR
2 Pages
-
LIK12TU
2 Pages
-
Smart Eco System
2 Pages
-
System M.
2 Pages
-
System M
15 Pages
-
System Zero
11 Pages
-
Heat Pump Assortment 2017
25 Pages
-
DHWE 51/81/101 SZ.
2 Pages
-
DHW 400+.
2 Pages
-
Dimplex Product Range 2017
77 Pages
-
Innovations for 2013
11 Pages
-
Splydro
2 Pages
-
BK infrared heaters
2 Pages
-
Heat Pumps
15 Pages
-
Factsheet SITU
2 Pages
-
Intelligent Quantum
4 Pages
-
Dimplex more heatpumps
5 Pages
-
LA_STU heatpump
6 Pages
-
Dimplex Heat Pumps 2014
31 Pages
-
NEWS 2013
11 Pages
-
Product Range Overview 2013
122 Pages
-
Dimplex Heat Pumps
40 Pages
Archived catalogs
-
BA series patio radiators
2 Pages
-
NEW (innovations 2011)
7 Pages
-
Product range
118 Pages