1. Catalogs
  2. DEVOREX PLC
  3. Gutter system ELEGANCE 140

Gutter system ELEGANCE 140

Gutter system ELEGANCE 140

Gutter system ELEGANCE 140

Product catalog summary

Overview and Application

The document provides technical specifications, installation guidelines, and product features for the DEVOREX roof drainage system, designed for rainwater management on residential, administrative, and light industrial buildings. The system complies with EN 12056-3 standards and must be designed by authorized professionals considering local building codes.

Design and Calculation Parameters

  • Rainfall intensity used for calculations: 80 liters per hour per square meter (80 l/(m²·h)).
  • Effective roof rainfall area calculation formula: S = (W + H/2) × L, where W, H, and L are roof dimensions.
  • Running outlet must be positioned at least 10 meters from the slope start.
  • Flow rates vary with slope and position of outlet, e.g., at 8 mm/m slope in the middle of the roof, flow rate is 4.4 l/sec for 200 m² area.

Product Features and Advantages

  • Available in multiple saturated colors (White RAL 9010, Grey RAL 7038, Brown RAL 8019, Beige RAL 1015, Terracotta RAL 8023, Bordeaux RAL 3009) with no need for painting.
  • Invisible gutter brackets provide a modern, hidden fixing system.
  • State-of-the-art UV protection ensures durability of PVC components.
  • Corrosion resistance extends product lifetime and reduces maintenance costs.
  • Reliable installation system allows secure fixation and thermal compensation for watertightness.
  • 2-in-1 design combines two gutter styles for flexibility and aesthetics.

Installation Guidelines

  1. Storage: Gutters and pipes must be stored above ground on wooden pallets or beams with supports every 50 cm, avoiding twisting or bending. Outdoor storage requires a minimum 5° slope for drainage.
  2. Do not cover system elements with foils that prevent air circulation.
  3. Operating temperature range: -35°C to +65°C.
  4. Handling: Avoid sliding pipes and gutters over each other to prevent surface damage.
  5. Bracket fixing: Attach gutter fascia brackets to fascia board using 5x30 mm screws or M6x50 bolts; maximum spacing between brackets is 50 cm; maintain 5-10 cm distance between brackets and other gutter elements.
  6. Gutter installation: Slide gutter edges under retaining clips, hang front edge on bracket clips without fixing to allow movement during installation; glue connecting elements with PVC-U glue at edges.
  7. Thermal expansion: Adjust gutter unions according to outside temperature during installation.
  8. Pipe brackets: Install at max 150 cm apart or 75 cm from pipe ends; secure brackets after placing pipes.
  9. Special fixings: Use bracket adaptors for tile or bitumen roofing; for roof ribs, use side or top rafter brackets with M6x50 bolts for slope adjustment.
  10. Warning: In heavy snowfall areas, avoid bracket adaptors or rafter brackets; fix gutters directly to fascia board.

Safety and Additional Recommendations

  • In regions prone to snow and ice, install ice/snow protection fixtures to prevent falling hazards.
  • Ensure all pipes and fittings are glued with PVC-U glue for watertight connections.
  • Use appropriate screws (M6) compatible with mounting surfaces for downspout end fittings.

Components and Accessories

The system includes a variety of components such as gutters (3 m lengths), gutter unions, stopends (right and left), angles (90° interior and exterior), running outlets (Ø100), rainpipes (Ø100), pipe connectors, brackets (fascia, rafter, adaptor for tile and bitumen roofing), bends (67.5° and 87.5°), ending bends, reducers (Ø100/Ø80), and fastening hardware (M6x50 bolts and nuts).

Contact Information

DEVOREX headquarters and distributor offices are located in Bulgaria (Plovdiv), Spain (Barcelona), and Romania (Bucharest), with contact details provided for technical support and sales inquiries.

Summary of Critical Parameters and Best Practices

  • Design must comply with EN 12056-3 and local codes.
  • Use rainfall intensity of 80 l/(m²·h) for calculations.
  • Maintain proper bracket spacing and gutter slope for optimal flow.
  • Account for thermal expansion during installation.
  • Use recommended fixings and adhesives to ensure durability and watertightness.
  • Install snow and ice protection in susceptible regions.
  • Store and handle components carefully to avoid damage.
See more

Catalog excerpts

Gutter system ELEGANCE 140-1

DESIGN Roof drainage system design should be performed by an authorized and experienced designer, considering the requirements of EN 12056-3 and strictly following all national and local building codes and standards. The product is fit for rainwater handling from the roofs of residential, administrative and light industry buildings. WARNING!!! In cases of installations on roofs of buildings in regions, susceptible to formation of snow and/or ice cover, please install suitable ice/snow protection fixtures on the roof, in order to prevent falling of ice/snow and serious damage to people and property. Conveniently combines two popular, elegant gutter styles in one product for higher flexibility. Distances between roofing tiles and gutters “INVISIBLE” BRACKETS Modern, “hanging” construction that employs strong gutter bracket, completely hidden behind the gutter profile. RELIABLE INSTALLATION The roofing tiles should be positioned according to the picture above. HEAD OFFICE BULGARIA Calculating Effective Roof Rainfall Area State - of the -art system for secure fixation and reliable thermal compensation, guarantees watertight installation. Bulgaria, Plovdiv Region, 4109 Brani pole, Zone Chiirite 020 G (South Ring road of Plovdiv, Bulgaria) tel.: (+359) 32 677 105, (+359) 32 677 205, fax: (+359) 32 677 305 www.devorex.com; e-mail: [email protected] The running outlet should be positioned minimum 10 m away from the beginning of the slope. FLOW RATES (calculations according to EN 12056-3) slope 8 mm/m Specially developed to meet the critical requirements of the PVC rainwater management. SATURATED COLOR OFFICE ROMANIA Significantly increases the usable lifetime, reducing maintenance and replacement costs. All calculations are based on rainfall intensity of 80 l/(m 2 x h) DEVOREX distributors Изчисленията са на база количество валежи 80 л./(час.м²)

 Open the catalog to page 1
Gutter system ELEGANCE 140-2

Components of system ELEGANCE Components of system ELEGANCE INSTALLATION MANUAL IN 4 EASY STEPS ELEGANCE 140 GUTTER ANGLE 90° - А EXT. Exterior for side А; Interior for side B ELEGANCE 140 GUTTER ANGLE 90° - А INT. Interior for side А; Exterior for side B 1. Considering the position of the downspout, fix the elements’ brackets, used for attaching the running outlet, to the fascia board. Using a stringline, set the gradient and position the gutter fascia brackets, beginning with the furthest from the running outlet. The distance between two gutter brackets should be maximum 50 cm, and between...

 Open the catalog to page 2

All DEVOREX PLC catalogs and technical brochures

  1. WPC DECKING

    2  Pages

  2. Soffit

    2  Pages

  3. Fencing

    2  Pages

  4. DEVOREX_PRIME

    2  Pages

  5. FAVORIT 130

    2  Pages

  6. SOFFIT

    2  Pages

  7. PRIME 125

    2  Pages

  8. PPR pipes

    2  Pages

  9. catalog DEVOREX

    72  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.