FAVORIT 130 - 1

13. Installation of pipe brackets - fix the pipe brackets to the wall at a maximum distance of 200 cm from each other and 15 cm from each pipe edge. For securing the brackets to the wall, use the element pipe bracket adapter. 14. Installation of ending bend - for an elegant open end of a downspout, use the element ending bend. To assemble to a pipe use a self-tapping screw on the back side. 15. Installation of universal gully - to directly connect the roof drainage system to the sewerage network use the element universal gully. STORAGE AND HANDLING The gutters and pipes should be stored above the ground level on a smooth surface without any roughness or sharp edges, providing support on every 50 cm. The products should be arranged freely without twisting or bending. Do not arrange them in heights of more than 1m. All fittings should be stored indoors in their original packaging in order to protect the products from damage or pollution. Ventilation should be provided for the products for the period of storage. They should not be wrapped or covered with transparent or opaque foils. To prevent surface scratching of gutters and pipes - do not slide one on top of the other. All system components are packaged in separate polyethylene sleeves, hence do not expose to direct sunlight for a long period of time. ATTENTION! The usage of elements from other manufacturers endangers the proper operation of the system. The warranty is valid only when the installation is solely made with elements of system FAVORIT 130. Swedish steel with polymer coating Gutter system FAVORIT 130 The project of a roof drainage system should be prepared by an authorized designer, considering the requirements of EN 12056-3 and strictly following all national and local standards in building planning. The product is intended for rainwater harvesting from the roofs of residential, administrative and industrial buildings. S = (W+H/2) L The running outlet should be positioned at least 10 m away from the beginning of the slope (All calculations acc. to EN 12056-3) Position of the outlet Effective roof rainfall area Distance between roofing tiles and gutters D The calculations are made based on rainfall intensity of 80 l/ m² x h Region Plovdiv, 4109 Branipole, zone Chiirite 020G (South ring road of Plovdiv) tel.: (+359) 32 677 105, fax: (+359) 32 677 305 e-mail: info@devorex.com

Open the catalog to page 1
FAVORIT 130 - 2

1. Mark the position of the outlet on the fascia board. Fix a gutter fascia bracket on each side of the outlet at a maximum distance of 15 cm from its edges. KEY а. Steel sheet - 0,6 mm thickness Four protective layers b. Galvanized layer c. Passivation layer d. Ground coat e. Polymer coating Prelaq® RWS 1. FAVORIT 130 Gutter, 3m 2. FAVORIT 130 Gutter union 3. FAVORIT 130 Outlet Ø90 4. FAVORIT 130 Interior angle 90° 5. FAVORIT 130 Exterior angle 90° 6. FAVORIT 130 Exterior angle 135° 7. FAVORIT 130 Interior angle 135° 8. FAVORIT 130 Gutter fascia bracket 9. FAVORIT 130 Top rafter bracket...

Open the catalog to page 2

All DEVOREX PLC catalogs and technical brochures

  1. WPC DECKING

    2 Pages

  2. Soffit

    2 Pages

  3. Fencing

    2 Pages

  4. SOFFIT

    2 Pages

  5. PRIME 125

    2 Pages

  6. PPR pipes

    2 Pages