Product catalog summary
Introduction
The document serves as the service and installation manual for the ACR-26S Air Curtain Refrigerator, effective from September 1998, detailing installation, operation, and maintenance instructions.
Specifications
The ACR-26S operates at 115V/60Hz/1ph, with a storage capacity of 12.5 ft³ and a tray capacity of 18" x 26". It has a BTU/HR of 3300 with the door closed and a shipping weight of 592 lbs.
Receiving and Inspecting
Inspect the equipment for visible damage upon receipt. Document any damage and notify the carrier, retaining all packaging materials until inspection is completed.
Installation
Ensure the installation site can support the refrigerator's weight. The unit should be level and not placed under air conditioning vents. Electrical connections must comply with local codes.
Maintenance
Regular cleaning with non-abrasive cleaners is recommended. Clean condenser fins every three months and door gaskets regularly to ensure proper sealing.
MCII Tempatrol® Function Settings
The MCII microprocessor is pre-set for optimal operation, including diagnostic entry, temperature range, and defrost termination temperature. The unit operates immediately upon start without additional programming.
Basic Operation
The refrigerator is preset to 37°F and the freezer to 0°F. The digital display flashes if the interior temperature exceeds the set range. The clock must be reset after power interruptions if custom defrost plans are used.
MCII Tempatrol® Controls
The control panel includes buttons for resetting alarms, setting the clock, and initiating defrost cycles. The display shows the current temperature and allows for adjustments.
Display Functions
The normal display shows the interior temperature. A flashing display indicates potential issues such as over-temperature or a door left ajar. The CHECK SYSTEM indicator alerts to significant malfunctions.
Warranties and Parts
The manual includes warranty information and a list of authorized parts depots for service and replacement parts.
Overview
The document provides detailed instructions for programming and operating the MCII Tempatrol® system, managing defrost cycles, temperature settings, and other functionalities in refrigeration units.
Defrost Cycles
The MCII Tempatrol® allows for automatic, custom, and manual defrost cycles. Automatic cycles are preprogrammed, while custom cycles can be set by the user. Manual defrosts can be initiated at any time.
Temperature Settings
Recommended storage temperatures are 0°F to –5°F for freezers and 35°F to 40°F for refrigerators. The system allows for adjustments within specified ranges and can display temperatures in Fahrenheit or Celsius.
Optional Settings
Users can lock control settings, set over-temperature alarms, and choose display options upon power-up. The system allows for setting a differential tolerance for temperature control.
Diagnostic and Troubleshooting
The MCII Tempatrol® includes a self-diagnostic system with error codes to assist in troubleshooting. Users can enter diagnostic mode to view codes and must clear error codes after repairs.
Wiring and Replacement Parts
The document includes wiring diagrams for specific models and lists replacement parts with their corresponding part numbers.
Parts List
  • Door assembly: 034-0011
  • Fan assembly, 8" diameter: 216-2687
  • Gasket, door: 170-1147
  • Handle assembly, rear: 034-0021
  • Hinge, bottom half (2): 005-5292
  • Hinge, top half (2): 005-5291
  • Lock: 323-4416
  • Louver, back: 005-5158
  • Louver, front: 005-5157
  • Module, power, MCII: 219-3987
  • Switch, rocker: 219-0154
  • Valve, expansion, 404A: 351-6084
Warranty Information
  • Standard One Year Limited Warranty: Covers parts for one year and labor for 90 days from the date of shipment or installation if the warranty card is returned within 30 days.
  • Exclusions: Does not cover misuse, neglect, alterations, accidents, or repairs by unauthorized personnel. Does not apply if the unit is moved from its original installation location.
  • Motor-Compressor Warranty: Additional four-year protection for the motor-compressor, excluding labor charges and certain components. Requires registration within 30 days of installation.
  • General Conditions: Delfield is not liable for delays or defaults due to uncontrollable circumstances such as natural disasters or supply shortages.
  • Limitations: No liability for special, incidental, or consequential damages. Warranty is exclusive and supersedes any prior representations.
Customer Service
  • For assistance, contact customer service at (800) 733-8829, (800) 733-8821, or (517) 773-7981.
  • Fax: (517) 773-3210
See more

Catalog excerpts

Service and Installation Manual-1

! ThB Firmt cholee in valus. Installation Manual Please read this manual completely before attempting to Install or operate this equipment! Notify carrier of damage! Inspect all components Immediately. See page 2.

 Open the catalog to page 1
Service and Installation Manual-2

Serial Number Information MCII TEMPATROL® REFERENCE CHARTS To view the serial number of the ACR-26S refrigerator, open the door of the unit. The serial number is located on the inside back wall in the top left corner of the unit. Aways have the serial number of your unit available when call- ing for parts or service. A complete list of authorized Delfleld parts depots is shown on the back cover of this manual. ©1998 The Delfleld Company. All rights reserved. Reproduction without written permission is prohibited. The starburst "1" symbol is a trademark and "Delfleld" is a registered trademark...

 Open the catalog to page 2
Service and Installation Manual-3

When the door is open, Delfield's patented air curtain design directs cold air across the cabinet opening, keeping hot air out and cold air in for extended periods of time. The unit will maintain a maximum of 45°F box temperature at 70°F ambient with the door open during peak production times, quickly returning to a normal 36°F. With the door closed, a maximum 40°F at 100°F ambient is maintained (normal operation) while running only 15% in an 85° room. Be sure the location chosen has a floor strong enough to sup- port the total weight of the cabinet and contents. Reinforce the floor if necessary...

 Open the catalog to page 3
Service and Installation Manual-4

MCll Function Settings The MCII microprocessor has been preset at the facto- ry for the following functions eliminating the need for programming when your unit arrives. These settings must be correct for your unit to operate properly. 6. Press reset button ***Basic function ("012") must be set first otherwise it will cancel out everything previously entered. Basic Operation - For Units Built With The MCII Tempatrol( After plugging the unit in and turning the power switch to ON, the unit will operate immediately upon start without any programming of the MCII Tempatrol® required. The freezer temperature...

 Open the catalog to page 4
Service and Installation Manual-5

MCII Tempatrol® Controls CHECK SYSTEM DEFROST AM PM DOOR AJAR ® CLEAN CONDENSER RESET RESET TIME DEFROST • Turns off alarms • Terminates the current defrost cycle • Returns display of cabinet temperature • Displays the current time (if set) • Allows setting the clock by pressing UP and DOWN buttons • Starts a manual defrost cycle when pressed simultaneously with DEFROST • Displays current defrost setting (A,3,4,6 or 8) • Allows setting defrost setting and times by pressing UP and DOWN buttons • Starts a manual defrost cycle when pressed simultaneously with TIME TEMP UP • Displays current tem-...

 Open the catalog to page 5
Service and Installation Manual-6

MCII Tempatrol® Display Functions (continued) Door ajar The DOOR AJAR indicator light will come on when a door is opened. If the door remains open for more than display will begin to flash. After three minutes, a loud beep is emitted every three sec- onds. The flashing display and warning beep will stop when RESET is pressed. If the door is not closed when RESET is pressed, the same cycle will repeat. Clean condenser indicator light is a mainte- nance reminder that comes on every 90 days. It will go off when the RESET button is The DEFROST indicator light comes on during defrosting cycles. The...

 Open the catalog to page 6
Service and Installation Manual-7

MCII Tempatrol® Programming (continued) Setting defrost cycles Setting defrost cycles on freezer units is done via the MCII Tempatrol. The automatic defrost cycle is preprogrammed at “3” in the factory, and no adjustment is needed to use the unit with this setting. A custom defrost cycle for freezers can be programmed if desired. For information on how to determine the proper defrost setting for your application, see page 9. Refrigerators defrost automatically; no adjustment is needed. Follow these steps to set or change the defrost cycle: CHECK SYSTEM DEFROST AM PM CHECK SYSTEM DEFROST AM PM...

 Open the catalog to page 7
Service and Installation Manual-8

MCII Tempatrol® Defrost Settings Refrigerators automatically defrost, using a special defrost program in the MCII Tempatrol®. A refrigerator will defrost whenever the MCII Tempatrol detects poor unit efficiency. A refrigerator defrost will rarely occur. However, under certain conditions, a defrost may be needed to assure optimum per- formance. Defrost cycles will occur more frequently at interior temperature settings of 34°F (1°C) or less. Frequent defrosts may also occur when room temperatures are unusually high. Refrigerator defrosts cannot be adjusted; however, pressing the RESET button will...

 Open the catalog to page 8
Service and Installation Manual-9

MCII Tempatrol® Optional Settings (continued) Locking control settings You can lock the control settings so that they cannot be changed without knowing how to unlock them. This will pre- vent unsupervised changes to the set point or defrost cycles. Ol) Press the TIME and DOWN buttons simulta- neously then press the TEMP button. STEPS 2) Press the DEFROST button. The condensing unit will shut off, and the display will read 000. 3) Press UP until the display reads 009. 4) Hold the TIME button, and press UP or DOWN until the display shows L for locked, or U for 5) Release the TIME button. The display...

 Open the catalog to page 9
Service and Installation Manual-10

MCII Tempatrol® Self-Diaqnostic System Check system indications A Whenever a CHECK SYSTEM indication ^Lj^. appears, a potentially serious problem has CAUTION occurred. Appropriate action should be taken immediately to ensure proper product temper- ature is maintained. A qualified service agent should be called whenever a serious problem You may be able to speed up the repair process, however, by noting the diagnostic codes provided on the digital display by the MCII when a problem occurs. Using the diagnostic mode Using the following instructions, enter the diagnostic mode and write down the...

 Open the catalog to page 10
Service and Installation Manual-11

MCII Tempatrol® Diagnostic Codes (Reference Chart) 1 Low evaporator tempe ratu re w ith high superheat orH (freeze E on ry) low s u perheat w ith low te mpe ratu re diffère noe Qeckevaporator for frost accu mu lationH Checkfans a nd eva porator air f lowH Qeckfor frost backto compressor for ove rchargeH Checkfor leaksH Checkfcc possible restriction in capillary tube and dirt or moisti NOTE Vacuate and recha rge afte ra ny corrective actions bow su pe rheat with h ig h te mpe ratu re diffère nee Qeckevaporator fansH Checkfcc frost on the eva porator coil No su perheat with no te mpe ratu re diffère...

 Open the catalog to page 11

All Delfield catalogs and technical brochures

  1. 4400 Series

    28  Pages

  2. F16DD

    2  Pages

  3. F5 & F15 SERIES

    20  Pages

  4. Drop-Ins

    8  Pages

  5. UTSP

    2  Pages

  6. Versa Drawer

    8  Pages

  7. Coolscapes

    4  Pages

  8. ESP

    2  Pages

  9. E-Chef

    2  Pages

  10. Display Case

    4  Pages

  11. DFN8200ST

    2  Pages

  12. DF442712M

    2  Pages

  13. DB4400

    4  Pages

  14. Concepts

    8  Pages

  15. Shelley

    8  Pages

  16. Convochill

    12  Pages

  17. 18600PTBM

    4  Pages

  18. F13 Series

    12  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.