Product catalog summary
Introduction
This manual provides detailed instructions for the installation and operation of the F5 and F15 Series Drop-In and Serview Display Cases. It emphasizes the importance of reading the manual thoroughly before installation or operation to ensure proper handling and functionality.
Important Information
Upon receipt, inspect all components immediately and report any damage to the carrier. Retain all packaging materials until the inspection is completed.
Specifications
  • F5 Series: Models range from 48" to 72" in width, operating on 115/60/1 volts with varying BTU capacities.
  • F15 Series: Similar to the F5 Series but with additional depth options and higher BTU capacities for certain models.
Installation
  • Location: Units are for indoor use only and should not be placed near high heat-generating equipment. Ensure the supporting surface can handle the weight of a fully loaded unit.
  • Plumbing: Self-contained models include a condensate evaporator. If absent or failed, ensure proper drainage to avoid hazards.
  • Electrical Connection: Verify the unit is connected to the correct power source as per local codes and the National Electrical Code.
Operation
Units are designed to maintain an interior temperature between 36°F (2°C) and 40°F (4°C) at 65% or lower ambient relative humidity. Ensure proper airflow for efficient operation.
Maintenance
Regular maintenance includes checking condenser airflow and ensuring the refrigeration lines are secure. Follow the manual for detailed maintenance procedures.
Replacement Parts
Information on replacement parts for various components such as doors, condensing units, and control assemblies is provided. Always have the serial number available when ordering parts.
Wiring Diagram and Warranties
Refer to the wiring diagram for electrical connections and review the standard warranties for coverage details.
Installation and Operation
The document provides detailed instructions for the installation and operation of Delfield's F5 and F15 Series display cases. It emphasizes the importance of connecting the unit to the correct voltage and amperage circuit. The self-contained units feature an ON/OFF switch located behind the louvered panel, and the unit should be disconnected from the power source during maintenance.
Temperature Control
The display cases are designed to maintain temperatures between 36°F to 40°F. Temperature adjustments should be made gradually using the control knobs located in the fan shroud and mechanical compartment. Continuous door operation can affect temperature maintenance.
Evaporator Fan Operation
The evaporator fan operates in sync with the compressor during cooling and pulses during the compressor off mode. During defrost cycles, the fan runs continuously.
Maintenance
Regular maintenance includes cleaning door gaskets, ensuring proper drainage, and maintaining casters. The document advises against using abrasive cleaners on stainless steel and emphasizes the importance of cleaning the condenser coil regularly to prevent compressor failure.
Air Flow and Installation
Proper air flow is crucial for the operation of F5 units, which require specific louvered panel installations. The document provides dimensions and installation guidelines to ensure adequate air flow.
Sliding Door Maintenance
The Pike sliding door assembly requires regular cleaning, and instructions are provided for door removal and reinstallation.
Parts and Components
The document lists various parts and components for the F5 and F15 Series, including condensing unit assemblies and fluorescent light fixtures, with part numbers for easy reference.
Parts List and Specifications
The document provides a detailed list of parts and specifications for various components used in Delfield equipment. This includes diffusers, lamps, lamp holders, screws, nuts, ballasts, and complete door assemblies with specific dimensions. Each part is identified by a unique part number and description.
Base Door Assembly
Details on complete door assemblies for different sizes (19", 24", 27", 32") are provided, including gaskets and hinges. The assembly instructions include part numbers for easy identification.
Evaporator and Pressure Control Assemblies
The document outlines the components of the F15 Base Evaporator Assembly and the Dual Pressure Control Assembly, listing parts such as coil assemblies, fans, expansion valves, and control units.
Miscellaneous Replacement Parts
A comprehensive list of miscellaneous parts for display cases and other equipment is included, covering items like fan blades, brackets, thermostats, and solenoid valves.
Labor Guidelines
The document specifies standard labor guidelines for repairing or replacing parts on Delfield equipment. It outlines the maximum time allowed for diagnosing and retrieving parts, as well as the reimbursement policy for travel and labor costs.
Warranty Information
Delfield offers a one-year limited warranty on parts and a 90-day labor warranty. The warranty covers defects in material and workmanship under normal use. Specific conditions and exclusions apply, such as misuse, neglect, or unauthorized repairs voiding the warranty.
Additional Warranty for Motor-Compressor
An additional four-year warranty is available for the motor-compressor, covering defects in material or workmanship. This warranty requires registration within 30 days of installation and excludes labor charges for part replacement.
Warranty Conditions
Delfield provides a warranty for the Motor-Compressor, which is void if methyl chloride is added to the system or if the unit is moved from its original installation location. The warranty covers the replacement of one defective Motor-Compressor within a four-year period at no charge. However, it does not allow for the purchase of a complete replacement Motor-Compressor unless authorized by Delfield, and only the wholesale cost is refundable if purchased locally.
General Conditions
Delfield is not liable for delays or defaults caused by uncontrollable events such as war, natural disasters, or supply shortages. The warranty excludes damages from spoilage of goods and supersedes any prior warranties. Delfield disclaims implied warranties of merchantability or fitness for a particular purpose.
Liability Limitations
Delfield will not be liable for special, incidental, or consequential damages. The warranty is exclusive and in lieu of all other warranties, except for any applicable Standard One Year Limited Warranty or Service Labor Contract.
Customer Support
For assistance, customers should have their model and serial numbers ready when calling Delfield's customer service. A list of authorized parts depots is available on their website.
Company Information
Delfield reserves the right to change designs or specifications without notice. The company is located in Mt. Pleasant, MI, and Covington, TN.
See more

Catalog excerpts

F5 and F15 Series-1

Delfield ™ ® F5 and F15 Series Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2. F5 and F15 SERIES Drop-In and Serview Display Cases TION FORMA IN ORTANT SE IMP ! FORE U EAD BE CTIONS R TRU O ESE INS AU TI N C TH SE SAVE PLEA May 2011

 Open the catalog to page 1
F5 and F15 Series-2

F5 & F15 Series Service and Installation Manual Serial Number Location Replacement Parts Receiving And Inspecting The Equipment The serial number on all self-contained F5 Series units is located near the condensing unit. On all remote F5 Series units the serial number is located on the drop-in frame. The serial number on all self-contained F15 Series units is located behind the compressor housing. On all remote F15 Series units the serial number is located behind the six inch Always have the serial number of your unit available when calling for parts or service. A complete list of authorized...

 Open the catalog to page 2
F5 and F15 Series-3

F5 & F15 Series Service and Installation Manual 24" (61 cm) Deep Remote Drop-In Refrigerated Display Cases EVAPORATOR DISPLAY AMPS HOUR 24" (61cm) Deep Self-Contained Drop-In Refrigerated Display Cases VOLTS/ CABINET SYSTEM R404A HERTZ/ LOAD BTU/ CAPACITY CHARGE, NEMA MODEL L D H PHASE AMPS HOUR BTU/HOUR H.P OZ. PLUG 30" (76.2cm) Deep Remote Drop-In Refrigerated Display Cases VOLTS/ CABINET ™™0/? D!SPiAY HERTZ/ LOAD BTU/ ^mulY MODEL L D H PHASE AMPS HOUR BTU °TD TEMP 30" (76.2cm) Deep Self-Contained Drop-In Refrigerated Display Cases VOLTS/ CABINET SYSTEM R404A HERTZ/ LOAD BTU/ CAPACITY CHARGE,...

 Open the catalog to page 3
F5 and F15 Series-4

F5 & F15 Series Service and Installation Manual 24" (61 cm) Deep Remote Serview Refrigerated Display Cases EVAPORATOR BASE DISPLAY CAPACITY CAPACITY PHASE AMPS HOUR BTU °TD TEMP BTU °TD TEMP 24" (61cm) Deep Self-Contained Serview Refrigerated Display Cases VOLTS/ CABINET SYSTEM R404A HERTZ/ LOAD BTU/ CAPACITY CHARGE NEMA MODEL L D H PHASE AMPS HOUR BTU/HOUR H.P OZ. PLUG 30" (76.2cm) Deep Remote Serview Refrigerated Display Cases vniTV CARINFT EVAPORATOR EVAPORATOR BASE HERTZ/ LOAD BTU/ DISPLAY CAPACITY CAPACITY MODEL L D H PHASE AMPS HOUR BTU °TD TEMP BTU °TD TEMP 30" (76.2cm) Deep Self-Contained...

 Open the catalog to page 4
F5 and F15 Series-5

F5 & F15 Series Service and Installation Manual Installation: Self-Contained F5 Series Units represented in this manual are for indoor use only. All self-contained units were tested at the factory to assure proper operation. The unit should not be installed directly next to high heat generating equipment (ranges, griddles, etc.). Be sure the location chosen has a counter strong enough to support the total weight of the cabinet and contents. A fully loaded model may weigh as much as 2,000 pounds! Reinforce the counter as necessary to provide for maximum loading. These units are installed by "dropping"...

 Open the catalog to page 5
F5 and F15 Series-6

F5 & F15 Series Service and Installation Manual Installation: Self-Contained F15 Series Units represented in this manual are for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. A fully loaded model may weigh as much as 3,000 pounds! Reinforce the floor as necessary to provide for maximum loading. For the most efficient refrigeration, be sure to provide good air circulation inside and out. Don't pack the refrigerator so full that air cannot circulate. Be sure that the exterior of the unit has access to ample air. Avoid...

 Open the catalog to page 6
F5 and F15 Series-7

F5 & F15 Series Service and Installation Manual Shelf Installation Display cases come with four epoxy coated wire shelves that Maximum weight for shelves is 75 pounds. Overloading shelves can damage equipment or M cause bodily injury. Display Lock Operation At the factory, the keys are taped to the display case. Follow the directions below to lock and unlock the display case. To lock: Line up key ridge with red dot. Insert key and rotate one-half turn. Remove key and push lock bolt in. To open: Line up ridge with red dot. Insert key and rotate key one-half turn. After turning the ON/OFF switch...

 Open the catalog to page 7
F5 and F15 Series-8

F5 & F15 Series Service and Installation Manual Display Temperature Control Settings The display temperature control Is located on the evaporator assembly on the celling of the display case. It Is field adjustable and does not require a service agent. The factory setting Is 2.5. Set toward 1 for higher temperatures and toward 7 for lower temperatures. Please make small incremental adjustments if a temperature adjustment is necessary. Contact the service department at Delfield +1 (989) 773- 7981 or your local service agent for additional assistance. Delfield is not responsible for charges incurred...

 Open the catalog to page 8
F5 and F15 Series-9

F5 & F15 Series Service and Installation Manual Door Gasket Maintenance Door gaskets require regular cleaning to prevent mold and mildew build up and also to retain the elasticity of the gasket. Gasket cleaning can be done with the use of warm soapy water. Avoid full strength cleaning products on gaskets as this can cause them to become brittle and crack. Never use sharp tools or knives to scrape or clean the gasket. Gaskets can be easily replaced and do not require the use of tools or an authorized service person. The gaskets are "Dart" style and can be pulled out of the groove in the door and...

 Open the catalog to page 9
F5 and F15 Series-10

F5 & F15 Series Service and Installation Manual F5 units are designed to be operated with two supplied louvered panels for proper air flow. Failure to provide the proper air flow will void the warranty. Louver cut-outs are 22" by 11" (55.9cm by 27.9cm) typical. Cut-outs are to begin a maximum of 4.00" (10.2cm) from the counter-top. Proper installation must provide for air flow to and from the condensing unit. Install as shown below. 48" Wide Units Air Flow Detail 72" Wide Units Air Flow Detail An "air duct" should be constructed from the air-intake louver to the condenser. This is recommended...

 Open the catalog to page 10
F5 and F15 Series-11

F5 & F15 Series Service and Installation Manual Pike Sliding Door All Delfield F5 Series and F15 Serles display cases feature a Pike® sliding door assembly. A typical Pike sliding door assembly Is shown In the Illustration at right. Frequent, regular cleaning with a mild soap and water solution will keep the tracks free of foreign matter and will Insure many The glass may be cleaned with one of the many commercial glass cleaners currently available. If It becomes necessary to replace a Pike sliding door assembly or a glass panel, have your unit's model and serial numbers available when you call...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.