Catalog excerpts
Delfield ™ ® F5 and F15 Series Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2. F5 and F15 SERIES Drop-In and Serview Display Cases TION FORMA IN ORTANT SE IMP ! FORE U EAD BE CTIONS R TRU O ESE INS AU TI N C TH SE SAVE PLEA May 2011
Open the catalog to page 1F5 & F15 Series Service and Installation Manual Serial Number Location Replacement Parts Receiving And Inspecting The Equipment The serial number on all self-contained F5 Series units is located near the condensing unit. On all remote F5 Series units the serial number is located on the drop-in frame. The serial number on all self-contained F15 Series units is located behind the compressor housing. On all remote F15 Series units the serial number is located behind the six inch Always have the serial number of your unit available when calling for parts or service. A complete list of...
Open the catalog to page 2F5 & F15 Series Service and Installation Manual 24" (61 cm) Deep Remote Drop-In Refrigerated Display Cases EVAPORATOR DISPLAY AMPS HOUR 24" (61cm) Deep Self-Contained Drop-In Refrigerated Display Cases VOLTS/ CABINET SYSTEM R404A HERTZ/ LOAD BTU/ CAPACITY CHARGE, NEMA MODEL L D H PHASE AMPS HOUR BTU/HOUR H.P OZ. PLUG 30" (76.2cm) Deep Remote Drop-In Refrigerated Display Cases VOLTS/ CABINET ™™0/? D!SPiAY HERTZ/ LOAD BTU/ ^mulY MODEL L D H PHASE AMPS HOUR BTU °TD TEMP 30" (76.2cm) Deep Self-Contained Drop-In Refrigerated Display Cases VOLTS/ CABINET SYSTEM R404A HERTZ/ LOAD BTU/ CAPACITY...
Open the catalog to page 3F5 & F15 Series Service and Installation Manual 24" (61 cm) Deep Remote Serview Refrigerated Display Cases EVAPORATOR BASE DISPLAY CAPACITY CAPACITY PHASE AMPS HOUR BTU °TD TEMP BTU °TD TEMP 24" (61cm) Deep Self-Contained Serview Refrigerated Display Cases VOLTS/ CABINET SYSTEM R404A HERTZ/ LOAD BTU/ CAPACITY CHARGE NEMA MODEL L D H PHASE AMPS HOUR BTU/HOUR H.P OZ. PLUG 30" (76.2cm) Deep Remote Serview Refrigerated Display Cases vniTV CARINFT EVAPORATOR EVAPORATOR BASE HERTZ/ LOAD BTU/ DISPLAY CAPACITY CAPACITY MODEL L D H PHASE AMPS HOUR BTU °TD TEMP BTU °TD TEMP 30" (76.2cm) Deep...
Open the catalog to page 4F5 & F15 Series Service and Installation Manual Installation: Self-Contained F5 Series Units represented in this manual are for indoor use only. All self-contained units were tested at the factory to assure proper operation. The unit should not be installed directly next to high heat generating equipment (ranges, griddles, etc.). Be sure the location chosen has a counter strong enough to support the total weight of the cabinet and contents. A fully loaded model may weigh as much as 2,000 pounds! Reinforce the counter as necessary to provide for maximum loading. These units are installed by...
Open the catalog to page 5F5 & F15 Series Service and Installation Manual Installation: Self-Contained F15 Series Units represented in this manual are for indoor use only. Be sure the location chosen has a floor strong enough to support the total weight of the cabinet and contents. A fully loaded model may weigh as much as 3,000 pounds! Reinforce the floor as necessary to provide for maximum loading. For the most efficient refrigeration, be sure to provide good air circulation inside and out. Don't pack the refrigerator so full that air cannot circulate. Be sure that the exterior of the unit has access to ample air....
Open the catalog to page 6F5 & F15 Series Service and Installation Manual Shelf Installation Display cases come with four epoxy coated wire shelves that Maximum weight for shelves is 75 pounds. Overloading shelves can damage equipment or M cause bodily injury. Display Lock Operation At the factory, the keys are taped to the display case. Follow the directions below to lock and unlock the display case. To lock: Line up key ridge with red dot. Insert key and rotate one-half turn. Remove key and push lock bolt in. To open: Line up ridge with red dot. Insert key and rotate key one-half turn. After turning the ON/OFF...
Open the catalog to page 7F5 & F15 Series Service and Installation Manual Display Temperature Control Settings The display temperature control Is located on the evaporator assembly on the celling of the display case. It Is field adjustable and does not require a service agent. The factory setting Is 2.5. Set toward 1 for higher temperatures and toward 7 for lower temperatures. Please make small incremental adjustments if a temperature adjustment is necessary. Contact the service department at Delfield +1 (989) 773- 7981 or your local service agent for additional assistance. Delfield is not responsible for charges...
Open the catalog to page 8F5 & F15 Series Service and Installation Manual Door Gasket Maintenance Door gaskets require regular cleaning to prevent mold and mildew build up and also to retain the elasticity of the gasket. Gasket cleaning can be done with the use of warm soapy water. Avoid full strength cleaning products on gaskets as this can cause them to become brittle and crack. Never use sharp tools or knives to scrape or clean the gasket. Gaskets can be easily replaced and do not require the use of tools or an authorized service person. The gaskets are "Dart" style and can be pulled out of the groove in the door...
Open the catalog to page 9F5 & F15 Series Service and Installation Manual F5 units are designed to be operated with two supplied louvered panels for proper air flow. Failure to provide the proper air flow will void the warranty. Louver cut-outs are 22" by 11" (55.9cm by 27.9cm) typical. Cut-outs are to begin a maximum of 4.00" (10.2cm) from the counter-top. Proper installation must provide for air flow to and from the condensing unit. Install as shown below. 48" Wide Units Air Flow Detail 72" Wide Units Air Flow Detail An "air duct" should be constructed from the air-intake louver to the condenser. This is...
Open the catalog to page 10F5 & F15 Series Service and Installation Manual Pike Sliding Door All Delfield F5 Series and F15 Serles display cases feature a Pike® sliding door assembly. A typical Pike sliding door assembly Is shown In the Illustration at right. Frequent, regular cleaning with a mild soap and water solution will keep the tracks free of foreign matter and will Insure many The glass may be cleaned with one of the many commercial glass cleaners currently available. If It becomes necessary to replace a Pike sliding door assembly or a glass panel, have your unit's model and serial numbers available when you...
Open the catalog to page 11All Delfield catalogs and technical brochures
-
EcoMark Fabrication Solutions
12 Pages
-
GURP-S technical sheet
2 Pages
-
18600PTBMP technical sheet
4 Pages
-
Chef Counters & Serving Systems
12 Pages
-
4400 Series
28 Pages
-
F16DD
2 Pages
-
F5 & F15 SERIES
20 Pages
-
Drop-Ins
8 Pages
-
Standard Color Chart
1 Pages
-
Carts & Kiosks Product Guide
16 Pages
-
UTSP
2 Pages
-
Shelley Solution Systems
2 Pages
-
Versa Drawer
8 Pages
-
Coolscapes
4 Pages
-
Mark 7 Custom Fabrication
16 Pages
-
Global Reach-Ins
4 Pages
-
ESP
2 Pages
-
Equipement Stands
4 Pages
-
E-Chef
2 Pages
-
Display Case
4 Pages
-
DFN8200ST
2 Pages
-
DF442712M
2 Pages
-
DB4400
4 Pages
-
Custom Fabricantion
8 Pages
-
Concepts
8 Pages
-
5415 Carts and Kiosk
8 Pages
-
TT, TT2 Shelleymatic
2 Pages
-
FT2-SN Shelleymatic
2 Pages
-
CT Shelleymatic
2 Pages
-
SSHRI-G series
2 Pages
-
Pizza Prep Tables
6 Pages
-
Specification Line®
4 Pages
-
Shelley
8 Pages
-
Convochill
12 Pages
-
4427N-12M Mega Top
2 Pages
-
6000XL & 6100XL Series Reach Ins
20 Pages
-
6000XL? Reach-In
6 Pages
-
Compact Refrigerators & Freezers
16 Pages
-
LiquiTec® Cold pans
4 Pages
-
18600PTBM
4 Pages
-
18PTB/18PTL/18PDL/F18 Series
5 Pages
-
F13 Series
12 Pages
-
Parts Catalog Fifth Edition
92 Pages
Archived catalogs
-
Drop-Ins_2012
5 Pages
-
Drawer system
2 Pages
-
Drop-Ins_2009
8 Pages
-
Service and Installation Manual
20 Pages
-
Drop-Ins Product solution
9 Pages