This manual serves as the service and installation guide for the F13 Series Ice Cream Cabinets, effective December 2006. It includes comprehensive instructions for installation, operation, maintenance, and troubleshooting, emphasizing the importance of reading the manual thoroughly before use.
Specifications
The manual details specifications for various models, including gallon capacity, voltage, BTU design, refrigerant charge, and shipping weight. For instance, the F13WC32 model has a 12-gallon capacity, operates on 115/60/1 volts, and requires a 24 oz refrigerant charge.
Receiving and Inspecting
Upon delivery, inspect the equipment for visible damage and report any issues to the carrier immediately. The manual provides steps for inspecting both the exterior and interior of the package and handling concealed damage.
Installation
Installation guidelines stress selecting a suitable indoor location with adequate air circulation and a strong floor. Instructions for leveling the cabinet and making electrical connections are provided, ensuring compliance with local and national electrical codes.
Operation
This section covers the basic operation of the ice cream cabinets, including manual defrosting and maintaining proper temperature settings. It advises against using sharp utensils for defrosting to prevent damage.
Maintenance
Regular maintenance is crucial for optimal performance. The manual recommends cleaning with non-abrasive cleaners and keeping condenser fins free of dust and grease. Instructions for cleaning compartment lids and using appropriate cleaning solutions are included.
Pressure Settings
Factory-recommended low-pressure control settings for self-contained models are provided, with specific cut-in and cut-out pressures. Significant adjustments should not be made without consulting a service agent.
Wiring Diagrams
Wiring diagrams for the 13BC and WC series assist with electrical troubleshooting and repairs.
Refrigerant Charges & Replacement Parts
Details on standard refrigerant charges and a list of replacement parts for various models are included, specifying refrigerant type and charge amounts for different units.
Standard Labor Guidelines
The manual outlines labor guidelines for repairs, including maximum allowable times for diagnosing defects, retrieving parts, and travel reimbursement. Specific labor times are allocated for replacing components like thermostats and fan motors.
Warranties
The Delfield Company offers a standard one-year warranty covering parts and 90 days for labor, with conditions for coverage and exclusions. An additional four-year protection plan covers the motor-compressor, requiring registration within 30 days of installation.
General Conditions
Delfield is not liable for delays or defaults due to uncontrollable contingencies. The warranty excludes spoilage of goods and unauthorized unit replacement. Implied warranties of merchantability or fitness for a particular purpose are disclaimed.
Customer Service
Customers should have model and serial numbers ready when contacting customer service. Contact information and a list of authorized parts depots are available on Delfield's website.
See more

Catalog excerpts

F13 Series-1

F13 Series Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 2. Ice Cream Cabinets N CAUTIO N RMATIO INFO RTANT USE IMPO EFORE S! READ B UCTION STR HESE IN ET Effective December 2006 ASE SAV PLE

 Open the catalog to page 1
F13 Series-2

F13 Series Ice Cream Cabinets Service and Installation Manual CONTENTS SERIAL NUMBER LOCATION SPECIFICATIONS 2 The serial number on self-contained units is located RECEIVING & INSPECTING 3 behind the louver near the compressor. The serial number on remote units is located in the mechanical REFRIGERANT CHARGES & REPLACEMENT ©2006 The Delfield Company. All rights reserved. Reproduction MODEL GALLON NUMBER OF VOLTS/HERTZ BTU DESIGN BTU REF CHARGE SHIP NUMBER CAPACITY COVERS H.P. PHASE AMPS LOAD SYS. CAP. OZ. WEIGHT Self-Contained Low Temp, Ice Cream Cabinet 5-15P NEMA plug used on all lengths MODEL...

 Open the catalog to page 2
F13 Series-3

F13 Series Ice Cream Cabinets Service and Installation Manual RECEIVING AND INSPECTING THE EQUIPMENT Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building. 1. Visually inspect the exterior of the package and skid or container. Any damage should be noted and reported to the delivering carrier immediately. 2. If damaged, open and inspect the contents with 3. In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should...

 Open the catalog to page 3
F13 Series-4

F13 Series Ice Cream Cabinets Service and Installation Manual These units use a "cold wall" design — heat is removed from the storage compartments through the liner walls. Products next to or touching the walls of the compartment will often be colder than items at the center of the compartment. For best results, store items loosely and keep them away from the side walls The units are not designed to reduce temperature quickly. When overloaded with warm items, it may take several hours to return to normal temperature, Also, frequent or continuous opening of the lids can affect the temperature...

 Open the catalog to page 4
F13 Series-5

F13 Series Ice Cream Cabinets Service and Installation Manual WIRING DIAGRAM: 13BC & WC SERIES For customer service, call (800) 733-8829, (800) 773-8821, (989) 773-7981, Fax (989) 773-3210, www.deleld.com 5

 Open the catalog to page 5
F13 Series-6

DELFIELD COPELAND relay, current capacitor, starting overload protector coll, condenser receiver tank DELFIELD COPELAND capacitor, starting overload protector coll, condenser receiver tank

 Open the catalog to page 6
F13 Series-7

F13 Series Ice Cream Cabinets Service and Installation Manual REPLACEMENT PARTS LISTS ON/OFF switch Cord & plug ON/OFF switch Pump, chocolate Jar, syrup, white "poly" Pump, regular syrup Cover, lift, lid & spoon ON/OFF switch Jar, syrup, white "poly" 3234100 Pump, regular syrup 3234114 Cover, lift, lid & spoon 3234051 Condensing unit, 1/2 H.P, Low 404A (72" only) 3526711 STANDARD REFRIGERANT CHARGES A There may be exceptions on specific Ar^. models. Charge amount should match

 Open the catalog to page 7
F13 Series-8

F13 Series Ice Cream Cabinets Service and Installation Manual STANDARD LABOR GUIDELINES TO REPAIR OR REPLACE PARTS ON DELFIELD EQUIPMENT Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage. • A maximum of 1-hour is allowed to diagnose a defective component. • A maximum of 1-hour is allowed for retrieval of parts not in stock. • A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed. • Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or...

 Open the catalog to page 8
F13 Series-9

F13 Series Ice Cream Cabinets Service and Installation Manual STANDARD ONE YEAR WARRANTY (One year parts, 90 days labor.) The Delfield Company ("Delfield") warrants to the Original Purchaser of the Delfield product (herein called the "Unit") that such Unit, and all parts thereof, will be free from defects in material and workmanship under normal use and service for a period of one (1 ) year from the date of shipment of the Unit to the Original Purchaser or, if the Original Purchaser returns the warranty card completely filled out including the date of installation within thirty (30) days of receipt...

 Open the catalog to page 9
F13 Series-10

F13 Series Ice Cream Cabinets Service and Installation Manual ADDITIONAL FOUR YEAR PROTECTION PLAN (for Motor-Compressor only) Delfield Model# Serial # Date In addition to the Standard One Year Warranty on the Motor- Compressor contained in the above listed Delfield product (the "Unit"), The Delfield Company ("Delfield") also agrees to repair, or exchange with similar or interchangeable parts in design and capacity at Delfield's option, the defective Motor-Compressor contained in the Unit (the "Motor-Compressor), or any part thereof, for the Original Purchaser only, at any time during the four...

 Open the catalog to page 10
F13 Series-11

F13 Series Ice Cream Cabinets Service and Installation Manual

 Open the catalog to page 11
F13 Series-12

Mt. Pleasant, MI Covington, TN Thank you for choosing Deleld! Help is a phone call away. Help our team of professional, courteous customer service reps by having your model number and serial number available at the time of your call (800) 733-8829. Model: ____________________ S/N: ___________________ Installation Date: ____________ For a list of Deleld’s authorized parts depots, visit our website at www.deleld.com. DM13 12/06

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.