1. Catalogs
  2. Delfield
  3. 4400 Series
cad

4400 Series

4400 Series
1 / 28 PagesView full catalog

4400 Series

Product catalog summary
Safety Notices: The manual stresses the importance of thoroughly reading instructions before operating, installing, or maintaining equipment to prevent damage, injury, or death. It warns against using damaged equipment, keeping power cords away from heat, and ensuring utility connections comply with codes. It also highlights risks from chemicals that may cause cancer and reproductive harm.
General Information: This section details serial number location, warranty registration, and certifications by NSF, UL, and cUL. It lists models covered, including refrigerated front breathers with doors, drawers, and raised rail prep tables.
Installation: The manual outlines installation conditions, such as ensuring a level, stable location free from combustible materials. It specifies clearance requirements, equipment weight, and the importance of air circulation. It warns against installing over drains and emphasizes compliance with fire and health codes.
Operation: Key instructions include power to cool, temperature control, and efficient operation. It covers defrosting and evaporator fan operation for optimal performance.
Maintenance: Regular maintenance is crucial for longevity. Guidelines are provided for cleaning interiors and exteriors, gasket maintenance, and preventing blower coil corrosion. Instructions for cleaning the condenser coil and maintaining doors and hinges are included.
Wiring Diagrams: This section contains essential wiring diagrams for troubleshooting and repairs, ensuring correct electrical connections.
Overview: The document provides detailed specifications, installation instructions, and operational guidelines for refrigerated front breathers with various configurations. It includes information on dimensions, electrical requirements, and installation procedures.
Specifications: Multiple models are listed with specific dimensions and capacities. Models are categorized by features such as doors, drawers, and backsplash. Key specifications include pan capacity, shelf area, and base volume.
Installation Instructions: Detailed steps for installing and leveling units, including leg or caster installation, are provided. The importance of proper grounding and electrical connections, adhering to codes, is emphasized.
Electrical Service: Electrical requirements, including amperage, voltage, and plug types, are outlined. Proper grounding and dedicated circuits are stressed.
Refrigeration Details: Information on BTU/hour capacity, heat of rejection, and refrigerant charge (R290) is provided. Maintaining proper refrigeration conditions is advised.
Safety Warnings: Warnings include electrical safety, proper drainage to prevent hazards, and secure installation to prevent movement.
Optional Features: Instructions for installing optional overshelves and heavy-duty cutting board brackets are included, with parts lists and assembly steps.
Maintenance and Adjustments: Guidelines for changing pan heights and installing shelves are provided to optimize cooling performance and storage efficiency.
Specifications and Assembly Instructions: Detailed specifications for parts like screws and bolts are provided, along with assembly instructions for components like the rolling lid and fixed cover.
Safety Warnings: Warnings include dangers of operating with damaged cords, standing on the unit, and overloading shelves. Safe food holding temperatures and avoiding blocked air grills are advised.
Operation Guidelines: The section outlines the cooling process, temperature control settings, and error codes. It emphasizes maintaining proper refrigeration temperatures and provides guidelines for efficient operation.
Maintenance Procedures: Detailed cleaning schedules are provided, stressing the importance of cleaning surfaces, gaskets, and condenser coils to prevent corrosion and ensure efficiency. Instructions for cleaning drawer assemblies and drain lines are included.
Critical Information: Equipment owners are responsible for hazard assessments and proper maintenance. Warnings against using sharp tools for cleaning and the importance of disconnecting power during maintenance are emphasized.
See more

Catalog excerpts

4400 Series-1

Compact Refrigerators 4400 Series Specifications, Installation, Operation & Maintenance Manual This manual is updated as new information and models are released. Visit our website for the latest information. Read this instruction before operating this equipment. Part Number: 9295093A 02/21 Original Document

 Open the catalog to page 1
4400 Series-2

Safety Notices nWarning nWarning Read this manual thoroughly before operating, installing or performing maintenance on the equipment. Failure to follow instructions in this manual can cause property damage, injury or death. DANGER Do not install or operate equipment that has been misused, abused, neglected, damaged, or altered/modified from that of original manufactured specifications. DANGER Never stand on the unit! They are not designed to hold the weight of an adult, and may collapse or tip if misused in this manner. DANGER Keep power cord AWAY from HEATED surfaces. DO NOT immerse power cord...

 Open the catalog to page 2
4400 Series-4

Section 1 General Information Serial Number Information Model Numbers The serial number is on the identification plate that also includes the model number. The identification plate is located near the top front corner of the left interior wall. This manual covers the following models: Always have the serial number of your unit available when calling for parts or service. 4427NP-6 One Door Salad Top 4427NP-8 4427NP-9M 4427NP-12M One Door Mega Top 4432NP-12M 4448NP-6 4448NP-8 Two Door Salad Top 4448NP-12 4448NP-6M 4448NP-12M Two Door Mega Top 4448NP-18M 4460NP-8 Two Door Salad Top 4460NP-12 4460NP-12M...

 Open the catalog to page 4
4400 Series-5

General Information Model Description D4464NP-18M Four Drawer Mega Top D4464NP-24M D4472NP-12 Six Drawer Salad Top D4472NP-18 D4472NP-18M D4472NP-24M Six Drawer Mega Top D4472NP-30M Refrigerated Front Breathers With Doors & 4” S/S Backsplash ST4427NP-6 One Door Salad Top ST4427NP-8 ST4448NP-6 ST4448NP-8 Two Door Salad Top ST4460NP-8 ST4460NP-12 ST4448NP-6M ST4448NP-12M Two Door Mega Top ST4460NP-12M ST4460NP-18M ST4464NP-8 Two Door Salad Top ST4464NP-12 ST4464NP-12M Two Door Mega Top ST4464NP-18M ST4472NP-12 Three Door Salad Top ST4472NP-18M Three Door Mega Top ST4472NP-24M Refrigerated Front...

 Open the catalog to page 5
4400 Series-6

Section 2 Installation DANGER Installation must comply with all applicable fire and health codes in your jurisdiction. DANGER Use appropriate safety equipment during installation and servicing. nWarning Do not damage the refrigeration circuit when installing, maintaining or servicing the unit. The location selected for the equipment must meet the following criteria. If any of these criteria are not met, select another location. • Units are intended for indoor use only. • The location MUST be level, stable and capable of supporting the weight of the equipment. • The location MUST be free from...

 Open the catalog to page 6
4400 Series-7

Weight of Equipment Model Ship Weight Refrigerated Front Breathers With Doors 223lbs (101kg) 240lbs (109kg)

 Open the catalog to page 7
4400 Series-8

Clearance Requirements • Keep the vents clean and free of obstruction. • Casters or optional legs must be used and not removed. • Provide good air circulation inside and outside the cabinet. • Do not pack refrigerator so full that air cannot circulate. • Avoid hot corners and locations near stoves and ovens. • These cabinets have Delfield’s “front-breathing” design. They may be installed flush against a wall or built into a counter as required. ,Caution Any restriction of the proper air flow outlined above, total or partial, will void the warranty on the cabinet. Dimensions Model Length Depth...

 Open the catalog to page 8
4400 Series-10

Electrical Service DANGER Check all wiring connections, including factory terminals, before operation. Connections can become loose during shipment and installation. nWarning This appliance must be grounded and all field wiring must conform to all applicable local and national codes. Refer to rating plate for proper voltage. It is the responsibility of the end user to provide the disconnect means to satisfy the authority having jurisdiction. • The Danfoss control can be used to power down and shut off the unit. • All electrical work, including wire routing and grounding, must conform to local,...

 Open the catalog to page 10
4400 Series-11

Voltage, Cycle, Phase NEMA Plug Drain Connections nWarning Moisture collecting from improper drainage can create a slippery surface on the floor and a hazard to employees. It is the owner’s responsibility to provide a container or outlet for drainage. Self-contained models are standard with a condensate evaporator. If, for some reason, a cabinet does not have a condensate evaporator, or the evaporator fails, the cabinets drain must have an outlet to an appropriate drainage area or container.

 Open the catalog to page 11
4400 Series-12

Refrigeration Model BTU/Hour Heat of R290 Charge Capacity Rejection Refrigerated Front Breathers With Doors

 Open the catalog to page 12
4400 Series-13

Level & Stable After the cabinet has been placed in the desired location, cabinets with legs must be leveled. Level units from front to back and from side to side. Leveling will insure proper door operation and removal of condensate. It is very important that all legs are properly adjusted to keep the cabinet level, evenly distribute the weight and to make sure the unit will not rock, lean or be unstable. If additional pan temperature cooling ability is desired, especially in higher ambient temperature conditions and/ or if pan covers are open or off for extended time periods improved cooling...

 Open the catalog to page 13
4400 Series-14

Section 2 If the overshelf was not ordered with the unit: 1. Set the overshelf in-place on the top of the cabinet. 2. Secure with three screws per side of the cabinet (total six screws). Optional Overshelf Installation Instructions If the unit is ordered to have the overshelf: 1. Remove the three screws from each top side of the cabinet (total six screws). 2. Set the overshelf in-place on the top of the cabinet. 3. Line up the overshelf holes with the unit holes. 4. Secure with three screws per side of the cabinet (total six screws).

 Open the catalog to page 14
4400 Series-15

Standard Heavy Duty Cutting Board Bracket Mounting Supplies Needed • #3 Phillips Screwdriver Parts Included For 27” & 32” Units Qty Left Bracket Right Bracket Screw, flat head Fender Washer Parts Included For 48” Units Qty Left Bracket Center Bracket Right Bracket Left Bracket Screw, flat head Fender Washer Parts Included For 60”, 64” & 72” Units Qty Left Bracket Center Bracket Right Bracket Screw, flat head Fender Washer Center Bracket Right Bracket

 Open the catalog to page 15
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.