DE-40 - 1

Parking. Surprisingly simple. DE-40 (without pit) SMART AND ELEGANT SOLUTION TO DOUBLE THE NUMBER OF PARKING SPACES Dependent Car Parking System on 2 Levels with an interactive control A Analogue Parking Technologies

Open the catalog to page 1
DE-40 - 2

DATA SHEET DE-40 SINGLE UNIT for 2 vehicles • Suitable for condominiums, hotels (short and long term parking), Car-Sharing and Valet-Parking. A modular design solution with at least • The parking spaces on the platforms are for trained and permanent users offers a high flexibility due to any extensions of • Indoor-Installation only. DE-40 (no pillars in the driving area) is our dependent Car Parking System with horizontal accessible platforms on two parking levels, installed above ground, without pit. Standard • 2000 kg, 500 kg wheel load Optional • 2600 kg, 650 kg wheel load The vehicle...

Open the catalog to page 2
DE-40 - 3

LENGTH DIMENSIONS DIMENSIONS in cm Installation length Installation length of min. 540 cm for vehicle length of up to 500 cm is required. For larger vehicles an installation length of min. 550 cm or 560 cm is recommended. This enables also larger safety distances, if newer, longer vehicles are purchased. H = clear height Other dimensions available on request. C1 = vehicle height bottom* C2 = vehicle height top* *Vehicle height Higher cars can be parked on the pLatform above in case of more ceiling height. The total vehicle height, including the roof rack, antenna, etc., must not exceed the...

Open the catalog to page 3
DE-40 - 4

*Bi: Usable parking width "B2: Parking width as per GaVo regulations The single units can be arranged in a modular design according to the available space. The Car Parking System provides efficient installation and use of space without interfering pillars in the driving area. Easy access for car and driver. SINGLE UNIT for 2 vehicles • Tolerance of dimensions on the construction site = 0 to + 3 cm. • The width of driving lanes must comply with local regulations. • We recommend a parking width of at least 250 cm for a comfortable parking. WIDTH DIMENSIONS I GARAGES with pillars in front of...

Open the catalog to page 4
DE-40 - 5

DATA SHEET DE-40 CONSTRUCTION REQUIREMENTS (see also planning notes) FORCES TO THE STRUCTURE F2 2000 kg 2600 kg F1 20 kN 25 kN F2 20 kN 25 kN • The forces apply to one pillar. • If pillars are next to each other the figure double, as both pillars are fixed in one point. ANCHORING & FLOOR REQUIREMENTS F2 F1 The systems are directly anchored into the floor and on the rear wall with heavy duty anchor bolts. The depth of the drill hole is approx. 13 cm. The base plate thickness must be minimum 20 cm with a concrete quality according to the static requirements of the building. Minimum...

Open the catalog to page 5
DE-40 - 6

DATA SHEET DE-40 PLANNING NOTES Hydraulic unit Placement next to the system, in partition Temperature range from - 5 to + 40° C. walls or on the wall (wall recess, niche). Relative humidity max. 80 %. Please contact Otherwise, an additional space is defined DE-PARK in case of different conditions. when planning. Maintenance, cleaning and prevention The systems must be serviced and cleaned regularly according to our operating instructions. Please ensure that there is sufficient drainage. Safety fences • Barriers Must be installed in the pedestrian area, accessible areas around the system as...

Open the catalog to page 6