DE-38 - 1

Parking. Surprisingly simple. DE-38 (with pit) DOUBLE THE NUMBER OF PARKING SPACES IN GARAGES FROM A CLEAR HEIGHT OF 320 cm Independent Car Parking System on 2 levels with an interactive control Analogue Parking Technologies Made in Germany

Open the catalog to page 1
DE-38 - 2

THE COMMON SOLUTION FROM A CLEAR HEIGHT of 320 cm. Single units for 2 vehicles Double units for 4 vehicles (combinable) DATA SHEET DE-38 • Suitable for residential buildings, office buildings and business premises, as well as for hotels. • For permanent and trained users only. • Indoor-Installation. VEHICLE WEIGHT (max.) Standard • 2000 kg, 500 kg Radlast Optional • 2600 kg, 650 kg Radlast DE-38 is our independent Car Parking System with horizontal accessible platforms and is installed on two levels, with pit. Our Standard Design for you! LEVEL PLATFORMS instead of TRAPEZOIDAL SHEETS PUSH...

Open the catalog to page 2
DE-38 - 3

free space 25 80 free space 4 ■ Clearance height in compliance with local regulation pit length 530 cm for vehicle length of up to 500 cm Drainage Please provide 1 to 2 % slope in the pit floor. Distance for drainage in the area of 200 bis 300 cm from the back wall. We recommend to install a drainage channel of 10 x 2 cm with drainage pit of 50 x 50 x 20 cm. Pit length Pit length of min. 530 cm for vehicle length of up to 500 cm is required. For larger vehicles an installation length of min. 540 cm is recommended. This enables also larger safety distances, if newer, longer vehicles are...

Open the catalog to page 3
DE-38 - 4

SINGLE UNIT for 2 vehicles WIDTH DIMENSIONS I Garages with pillars inside the pit Supporting pillars in the pit may protrude a maximum of 120 cm deep into the pit (measured from the front edge of the pit) into the pit. Please contact us with your planning. © DE-PARK GmbH | Technical modifications are reserved | DE-38_V01_2021_04_29_EN

Open the catalog to page 4
DE-38 - 5

ANCHORING & FLOOR REQUIREMENTS The systems are directly anchored into the floor with heavy duty anchor bolts. The depth of the drill hole is approx. 13 cm. The base plate thickness must be minimum 20cm with a concrete quality according to the static requirements of the building. Minimum requirement of the concrete quality is C20/25. The precise position of the load application points is available on request. OPENINGS AND WALLS In case of partition walls, 15 x 15 cm opening for electric cables and hydraulic pipes is necessary. Please do not close off opening The forces apply to one pillar....

Open the catalog to page 5
DE-38 - 6

DATA SHEET DE-38 CONTROL AND OPERATION THE NEW GENERATION: OPERATION VIA PUSH-BUTTONS More comfort and more safety by using of an interactive, innovative control unit with two push buttons (lifting and lowering), an emergency stop, Wall mounting (in-wall a key-swicth for system release and illumination to visualize the system status easily. or with a control column unit, see page 2. Choose your parking space easily by pushing the buttons (keep pressed push buttons for lifting and lowering). PLANNING NOTES Hydraulic unit Placement in partitions walls or on the wall Temperature range from - 5...