Innovens Pro
8Pages

{{requestButtons}}

Catalog excerpts

Innovens Pro - 1

Innovens I HAVE TO OPTIMISE THE AVAILABLE PLACE SOLAR SOLI D FUE L PROJECT I’M LOOKING FOR AN ECONOMIC AND ENVIRONMENTALLY FRIENDLY SOLUTION H EAT PUMPS CON DE NSI NG OI L/GAS Innovens Pro PROJECT Innovens MCA boilers Minimum space requirement for maximum output • 69 kg for an output of 114 kW • A big compactness L 750 x H 500 x D 500 for all the ranges Answers for the future Model Max. nominal output at 50/30°C Efficiency in % LCV 100% Ave. Temp 70°C loading on …% 100% Return Temp 30°C a water temp. …°C 30% Return Temp 30°C Nominal water flow rate at Pn and Δt = 20 K Standby losses at Δt = 30 K % losses through the outer casing Auxiliary electrical power at Pn/pmin (ex circulating pump) Output at 50/30°C min/max Output at 80/60°C min/max Min/max mass flue gas flow rate Pressure at boiler outlet Water content Minimum water flow rate required (*) Water resistance Δt = 20 K Gas flow rate natural gas H/L (15°C – 1013 mbar) Propane Weight empty • NOx emissions less than 46 mg/kWh (MCA 35E, 45 and 65) • Improvement in operating efciency +15% annual on LCV of up to109% • Modulation from 18 to 100% MCA 45 kW % % % m3/h W % W kW kW kg/h Pa l m3/h mbar m3/h m3/h kg MCA 65 MCA 90 MCA 115 43 97,2 102,9 107,7 1,72 NC 75 68/18 8,9-43 8-40 14/69 150 5,5 0,4 90 4,4/5,0 1,7 53 65 98,3 104,6 108,9 2,62 NC 75 88/23 13,3-65,0 12-61 21/104 100 6,5 0,4 130 6,6/7,5 2,5 60 89,5 97,9 104,1 108,1 3,62 NC 75 125/20 15,8-89,5 14,1-84,2 28/138 160 7,5 0,4 140 9,1/9,8 3,5 68 115 96,6 102,5 107,1 4,60 NC 75 199/45 18,4-114 16,6-107 36/178 220 7,5 0,4 250 11,7/13,7 4,7 69 **** (*) If operating > 75°C, the minimum flow rate should be calculated at Δt = 45 K ENERGY PERFORMANCE LOW TEMPERATURE GAS BOILER 11% of heat from condensation not used 6% losses through the ue gases 1% losses through radiation 111% based on LCV 111% par rapport au PCI HEATING BODY IN CAST ALUMINIUM-SILICIUM • Aluminium is a very good heat conductor (7 times greater than steel, for example) and the exchange of heat is therefore optimised. Its low weight (3 times lighter than steel) also makes it possible to design boilers which are very easy to handle. A MARK OF EXCELLENCE GAS CONDENSING BOILER 0,5% of heat from condensation not used 1% losses through the ue gases 0,5% losses through radiation 111% based on LCV 111% par rapport au PCI • The heating bodies in cast aluminiumsilicium are perfectly suited to condensing technology. Aluminium-silicium is resistant to the acid condensates which are a product of ue gases. And the silicium improves resistance to corrosion by the water used in heating. >> Compact, light and powerful >> Optimised for the environment >> Cascade systems For 300 years, De Dietrich’s success was based on some key fundamental values: quality, reliability, durability. Through its concern for the environment and for your comfort, De Dietrich has now a comprehensive understanding of the various renewable energies through multi-energy systems that protect the planet. Therefore, heating appliances which bear the De Dietrich name are at the cutting-edge of innovation and have the advantage as they benets from the commitment and the on-going expertise of their 2400 employees. De Dietrich: choosing Sustainable Comfort® 109% operating efciency PROJECT: CUSTOMISED SOLUTIONS FOR THE WHOLE BUILDING dediet10080849_innovens_ANG_prescrip .indd 1 Condensing boilers working for everyone 93% operating efciency Sustainable Comfort® De Dietrich Thermique PLC with corporate capital of € 21,686,370 57, rue de la Gare - F-67580 Mertzwiller Tél. +33 3 88 80 27 00 - Fax +33 3 88 80 27 99 www.dedietrich-heating.com LED lighting for your convenience TRIED AND TESTED PERFORMANCE FOR COMMERCIAL OUTLETS Réf. 300025154 - 09/2010. Photos not contractually binding. CONDENSING BOILERS FOR A BETTER USE OF ENERGY NEW Energy-saving, environmental friendly, offering excellent performances, the new generation of De Dietrich condensing boilers satises the problematics of current projects Today, De Dietrich is expanding its condensing range with wall-hung boilers from 8 to 115 kW to provide an appropriate response, whatever the conguration. << dedietrich-heating.com >> Sustainable Comfort® 7/10/10 9:50:23

Open the catalog to page 1
Innovens Pro - 2

Innovens I HAVE TO OPTIMISE THE AVAILABLE PLACE SOLAR SOLI D FUE L PROJECT I’M LOOKING FOR AN ECONOMIC AND ENVIRONMENTALLY FRIENDLY SOLUTION H EAT PUMPS CON DE NSI NG OI L/GAS Innovens Pro PROJECT Innovens MCA boilers Minimum space requirement for maximum output • 69 kg for an output of 114 kW • A big compactness L 750 x H 500 x D 500 for all the ranges Answers for the future Model Max. nominal output at 50/30°C Efficiency in % LCV 100% Ave. Temp 70°C loading on …% 100% Return Temp 30°C a water temp. …°C 30% Return Temp 30°C Nominal water flow rate at Pn and Δt = 20 K Standby losses at Δt =...

Open the catalog to page 2
Innovens Pro - 3

Innovens I HAVE TO OPTIMISE THE AVAILABLE PLACE SOLAR SOLI D FUE L PROJECT I’M LOOKING FOR AN ECONOMIC AND ENVIRONMENTALLY FRIENDLY SOLUTION H EAT PUMPS CON DE NSI NG OI L/GAS Innovens Pro PROJECT Innovens MCA boilers Minimum space requirement for maximum output • 69 kg for an output of 114 kW • A big compactness L 750 x H 500 x D 500 for all the ranges Answers for the future Model Max. nominal output at 50/30°C Efficiency in % LCV 100% Ave. Temp 70°C loading on …% 100% Return Temp 30°C a water temp. …°C 30% Return Temp 30°C Nominal water flow rate at Pn and Δt = 20 K Standby losses at Δt =...

Open the catalog to page 3
Innovens Pro - 4

EASIER ASSEMBLY AND MAINTENANCE A SOLUTION FOR EVERY SITUATION Lmax Lmax = L1+L2 • They can be tted alone or in cascade: - attached to a wall (7 max) - in line on the oor (7 max) - back to back on the oor (10 max; 5+5). As they take up less space and are low in weight, these boilers are easy to install. They are also tted with devices that make easier handling during maintenance and reduce this expense in the annual budget! Example of air/ue gas connection L1 Lmax C33x • Dimensions identical for the entire range • A very low noise level, thanks to a silencer tted to the air inlet. • The...

Open the catalog to page 4

All DE DIETRICH catalogs and technical brochures

  1. HPI-S

    32 Pages

  2. ALEZIO S

    32 Pages

  3. HPI-M

    28 Pages

  4. STRATEO

    32 Pages

  5. Naneo

    6 Pages

  6. Innovens

    6 Pages

  7. Twineo

    6 Pages

  8. Modulens

    44 Pages