video corpo

HPI-S

HPI-S
1 / 32 PagesView full catalog

HPI-S

Product catalog summary
Overview: The document provides comprehensive technical specifications and operational guidelines for the HPI-S range of air-to-water inverter heat pumps. These pumps are compact, high-performing, and reversible, suitable for both heating and cooling. They operate efficiently in temperatures as low as -20°C and achieve a COP of up to 5.11 at +7/+35°C. An optional insulation kit is available for air conditioning with fan coil units.
Components: The system includes an outdoor inverter unit and an indoor module. The indoor module features a DIEMATIC Evolution control panel, high-efficiency pumps, and a hydraulic filter with an isolating valve. It is available in two versions: MIT-S/E with an integrated electrical heater and MIT-S/H with a boiler for auxiliary heating.
Operating Conditions: The heat pumps have specific temperature limits for heating, cooling, and air conditioning. The maximum operating pressure for the heating circuit is 3 bar, with a maximum temperature of 95°C for the MIT-S/H version and 75°C for the MIT-S/E version.
Models and Performance: The HPI-S range offers models with heating outputs from 4.6 to 24.4 kW. Technical specifications include heating and cooling outputs, COP, EER, and sound power levels. The pumps are compatible with the SMART TC° thermostat and DIEMATIC control system.
Energy Efficiency: The heat pumps come with an energy label indicating efficiency, annual energy consumption, and noise level. They can be integrated with systems like solar panels or DHW storage tanks for improved performance and a system energy label.
Technical Specifications: Detailed tables provide information on heating and cooling capacities, energy efficiency ratings, and operational parameters for each model. Graphs illustrate the relationship between outside air temperature and water temperature output.
Conclusion: The HPI-S heat pumps are versatile and efficient for heating and cooling, suitable for renovations and new builds. Their high performance, energy efficiency, and modern control system compatibility make them a reliable choice for sustainable comfort.
Technical Specifications Overview:
1. Performance Data: Detailed performance data for various models include output in kW and efficiency ratings (EER and COP) at different flow and outside temperatures. This data is crucial for appropriate sizing, though not certified.
2. Indoor Module Specifications: The MIT-S indoor module specifications include dimensions, component details, and connection options. Key components are a decoupling tank, expansion vessel, heating safety valve, and high-efficiency heating pump, with a DIEMATIC Evolution control panel for advanced management.
3. Outdoor Unit Specifications: Specifications cover dimensions and components like the evaporator, fan, compressor, and electronic board. Gas and refrigerant fluid connections are specified, with limitations on distance and cooling capacity for certain configurations.
4. Control System Features: The DIEMATIC Evolution control panel offers advanced control options, including programmable electronic control, circuit management, and integration with domestic hot water systems. It supports hybrid systems and provides energy consumption estimates.
5. Additional Features and Options: Optional packages enhance system functionality, such as silencer kits, humidity sensors, and programmable thermostats, allowing customization and optimization.
Hybrid Heating System Integration: The document discusses integrating a hybrid heating system combining a heat pump and a boiler to optimize energy efficiency and reduce electricity bills. Benefits include energy savings, reduced CO2 emissions, and compatibility with existing heat emitters.
Primary Energy: The concept of primary energy is explained, including the energy used for transformation and transportation. The primary energy coefficient is 2.4 for electricity and 1.2 for natural gas and oil.
Performance Levels of Hybrid Solutions: A comparison of performance (COP) in terms of primary energy for heating and DHW production shows improved performance with a hybrid solution over using a heat pump or boiler alone.
Control System and Operating Principles: The control system manages the operation of the heat pump and boiler based on outside air temperature and the heat pump's COP, optimizing for primary energy consumption and energy costs.
Optional Equipment and Hydraulic Modules: Various optional equipment and hydraulic modules enhance functionality, including internal and external 3-way valve kits, insulated collectors, and hydraulic modules for different circuit configurations.
Sizing and Installation: Guidelines emphasize the need for backup systems at low temperatures and offer recommendations for installing HPI-S heat pumps, including location considerations, wind protection, and adequate ventilation.
Specifications and System Overview: The document outlines specifications for the HPI-S heat pump system, including a MIT-S/E module and an insulation kit HK25. It features one circuit with a mixing valve, a cooling circuit with fan coils, and DHW production by an independent calorifier BEPC 300, operating at 230V/400V with a frequency of 50Hz.
Installation Components: A detailed list of components required for installation includes safety valves, pressure gauges, flowmeters, automatic air vents, isolation valves, mixing valves, heating pumps, expansion vessels, and various sensors.
Energy Efficiency and Eco-Design: The ECO-SOLUTIONS label by De Dietrich ensures compliance with European Ecodesign Directives for energy-related products, guaranteeing efficiency, economy, and environmental friendliness.
Recommendations: To maximize performance and lifespan, proper installation, commissioning, and maintenance are recommended. De Dietrich offers a commissioning service and suggests a maintenance contract for optimal operation.
See more

Catalog excerpts

HPI-S-1

HPI-S REVERSIBLE AIR-TO-WATER ˝SPLIT INVERTER˝ HEAT PUMPS New Diematic Evolution interface • HPI-S /E from 4.6 to 24.4 kW with additional heating by integrated electrical resistance • HPI-S/H from 4.6 to 24.4 kW with additional hydraulic heating by boiler (or without additional heating) HPI-S /E (with electrical backup): heating and refreshing with underfloor heating/cooling or heating and air conditioning using fan coil units. HPI-S/H (with hydraulic backup): heating and refreshing with underfloor heating/cooling or heating and air conditioning using fan coil units. Air-to-water heat pump Free, natural and renewable energy Electricity (power supplied to the compressor) Compatible room thermostat SMART TC° Compatible regulation DIEMATIC OPERATING CONDITIONS operating temperature limits In heating mode Outside air: - 20/+ 35°C (- 15°C with AWHP 4.5 and 6 MR) Water: + 18/+ 60°C (+ 55°C for 4.5 kW) In cooling mode Outside air: +7/+ 46°C Water: + 18/+ 25°C In air conditioning mode Outside air: + 7/+ 46°C Water: + 7/+ 25°C Heating circuit Max. operating pressure: 3 bar Max. operating temp.: 95°C with …/H and 75°C with …/E HPI-S heat pumps stand out for their compactness and high performances: operation down to -20°C and COP up to 5.11 at +7/+35°C. They are reversible and can be used for heating and for cooling in summer. They can also be equipped with an optional «insulation kit» for air conditioning using fan coil units. They are composed of an outdoor «Inverter» unit, which is connected to the inside module by cooling connections. The indoor module comes fully equipped and includes, in particular: • DIEMATIC Evolution control panel with control system that can be programmed according to the outside temperature that communicates with the outdoor unit and, depending on the options connected, can be used to manage up to 3 heating circuits, direct or with mixing valves and a domestic hot water production circuit. Option of connecting HPI heat pumps and boilers with DIEMATIC Evolution control system in cascade; • High energy efficiency pumps (EEI < 0.23); • Hydraulic filter with isolating valve. This module is available in 2 versions: • MIT-S /E for auxiliary heating by integrated electrical heater, which can be wired as either 2 or 6 kW single-phase, 4 or 12 kW three-phase (cannot be installed without the heat pump) • MIT-S /H for auxiliary heatin

 Open the catalog to page 1
HPI-S-2

PRESENTATION OF THE RANGE The HPI S range of air/water Inverter heat pumps comes in models of 4.6 to 24.4kW (heating output at +7/+35°C in accordance with the EN 14511-2 standard). They comprise an outdoor unit and a MIT-S indoor unit. AWHP OUTDOOR MODULE TECHNICAL DATA The AWHP 4.5 MR to 27 TR outdoor modules are used in our current split air-to-water ranges. The outdoor module comprises: • a modulating compressor, an aluminium fin heat exchanger • 1 to 2 axial fan(s) (depending on the model) • a liquid separator and power reserve • a 4-way reversal valve • a HP pressure switch and a pressure...

 Open the catalog to page 2
HPI-S-3

MODELS AVAILABLE HPI-S... E MODELS AND HPI-S... H MODELS ADVANCE BACKUP HEAT PUMPS VIA INTEGRATED IMMERSION HEATER Heat pump with electrical backup for heating using radiators and cooling with underfloor heating/ cooling. Heat pump with hydraulic backup via boiler for radiator heating and cooling with underfloor heating/ cooling. 2 OR 6 KW SINGLE-PHASE HPI-S 4.5 MR/E HPI-S 6 MR/E HPI-S 8 MR/E HPI-S 11 MR/E HPI-S 16 MR/E - 4 OR 12 KW THREE-PHASE HPI-S 11 TR/E HPI-S 16 TR/E HPI-S 22 TR/E HPI-S 27 TR/E - HYDRAULIC VIA BOILER (OR WITHOUT BACKUP) HPI-S 4.5 MR/H HPI-S 6 MR/H HPI-S 8 MR/H HPI-S 11 MR/H...

 Open the catalog to page 3
HPI-S-4

TECHNICAL SPECIFICATIONS HPI-S TECHNICAL SPECIFICATIONS OPERATING TEMPERATURE LIMIT In heating mode: • Water: + 18°C/+ 60°C (+55°C for 4.5-kW model), • Outside air: - 20°C/+ 35°C (- 15°C for 4.5- and 6-kW models) MODEL SEASONAL PERFORMANCES Energy class in heating ERP (35°C) Energy class in heating ERP (55°C) SCOP (35°C/55°C) Seasonal space heating energy efficiency under average temperature (35°C/55°C) * Seasonal space heating energy efficiency under average temperature (35°C/55°C) (with outdoor sensor supplied as standard) CERTIFIED THERMAL PERFORMANCE Heating output at +7°C/+35°C (1) Heating...

 Open the catalog to page 4
HPI-S-5

TECHNICAL SPECIFICATIONS HPI-S WATER TEMPERATURE HPI-S heat pump models can produce hot water up to a temperature of 60°C (55°C for 4.5 kW). The graph shows the water temperature produced for each model based on the outside temperature.

 Open the catalog to page 5
HPI-S-6

TECHNICAL SPECIFICATIONS TABLES FOR SIZING HPI-S 4.5 MR FLOW TEMPERATURE [°C] HEATING 35 40 45 FLOW TEMPERATURE [°C] HEATING 35 40 45 FLOW TEMPERATURE [°C] HEATING 35 40 45 FLOW TEMPERATURE [°C] HEATING 35 40 45

 Open the catalog to page 6
HPI-S-7

TECHNICAL SPECIFICATIONS HPI-S 16 MR/TR FLOW TEMPERATURE [°C] HEATING 35 40 45 FLOW TEMPERATURE [°C] HEATING 35 40 45 FLOW TEMPERATURE [°C] HEATING 35 40 45 These performance levels are not certified, so they should only be used to size the heat pump.

 Open the catalog to page 7
HPI-S-8

MIT-S INDOOR MODULE SPECIFICATIONS MAIN DIMENSIONS (mm AND INCHES) MIT-S 510 KEY ቢ Return 3-way valve circuit Ø G 1 (option) • with HK21 package: internal 3-way valve set or • with HK22 package: adaptation kit for external 3-way valve ባ Flow 3-way valve circuit Ø G 1 (option) • with HK21 package: internal 3-way valve set or • with HK22 package: adaptation kit for external 3-way valve ቤ Direct circuit return G 1" ብ Direct circuit flow G 1" ቦ Gas refrigeration connection: see below ቧ Refrigerant fluid connection: see below ቨ Connection to boiler flow Ø G 1" (MIT-S/H only) ቩ Connection to boiler...

 Open the catalog to page 8
HPI-S-9

TECHNICAL SPECIFICATIONS MIT-S INDOOR MODULE SPECIFICATIONS COMPONENTS • MIT-S /H TR 40L decoupling tank 10L expansion vessel Heating safety valve (3 bar) Interface PCB: electronic boards accessible under the cover E High efficiency heating pump for direct circuit with EEI < 0.23 F Angled DIEMATIC Evolution control panel A B C D G Automatic air vent H High energy efficiency primary circulating pump I Condenser in the form of a stainless steel plate exchanger J Flowmeter K Magnetic filter 10L expansion vessel 40L decoupling tank Heating safety valve (3 bar) Interface PCB: electronic boards accessible...

 Open the catalog to page 9

All DE DIETRICH catalogs and technical brochures

  1. ALEZIO S

    32  Pages

  2. HPI-M

    28  Pages

  3. STRATEO

    32  Pages

  4. ESSENCIO ECONOX

    20  Pages

  5. Naneo

    6  Pages

  6. Innovens

    6  Pages

  7. Twineo

    6  Pages

  8. Modulens

    44  Pages

  9. Innovens Pro

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.