HPI-S - 1

HPI-S REVERSIBLE AIR-TO-WATER ˝SPLIT INVERTER˝ HEAT PUMPS New Diematic Evolution interface • HPI-S /E from 4.6 to 24.4 kW with additional heating by integrated electrical resistance • HPI-S/H from 4.6 to 24.4 kW with additional hydraulic heating by boiler (or without additional heating) HPI-S /E (with electrical backup): heating and refreshing with underfloor heating/cooling or heating and air conditioning using fan coil units. HPI-S/H (with hydraulic backup): heating and refreshing with underfloor heating/cooling or heating and air conditioning using fan coil units. Air-to-water heat pump Free, natural and renewable energy Electricity (power supplied to the compressor) Compatible room thermostat SMART TC° Compatible regulation DIEMATIC OPERATING CONDITIONS operating temperature limits In heating mode Outside air: - 20/+ 35°C (- 15°C with AWHP 4.5 and 6 MR) Water: + 18/+ 60°C (+ 55°C for 4.5 kW) In cooling mode Outside air: +7/+ 46°C Water: + 18/+ 25°C In air conditioning mode Outside air: + 7/+ 46°C Water: + 7/+ 25°C Heating circuit Max. operating pressure: 3 bar Max. operating temp.: 95°C with …/H and 75°C with …/E HPI-S heat pumps stand out for their compactness and high performances: operation down to -20°C and COP up to 5.11 at +7/+35°C. They are reversible and can be used for heating and for cooling in summer. They can also be equipped with an optional «insulation kit» for air conditioning using fan coil units. They are composed of an outdoor «Inverter» unit, which is connected to the inside module by cooling connections. The indoor module comes fully equipped and includes, in particular: • DIEMATIC Evolution control panel with control system that can be programmed according to the outside temperature that communicates with the outdoor unit and, depending on the options connected, can be used to manage up to 3 heating circuits, direct or with mixing valves and a domestic hot water production circuit. Option of connecting HPI heat pumps and boilers with DIEMATIC Evolution control system in cascade; • High energy efficiency pumps (EEI < 0.23); • Hydraulic filter with isolating valve. This module is available in 2 versions: • MIT-S /E for auxiliary heating by integrated electrical heater, which can be wired as either 2 or 6 kW single-phase, 4 or 12 kW three-phase (cannot be installed without the heat pump) • MIT-S /H for auxiliary heatin

Open the catalog to page 1
HPI-S - 2

PRESENTATION OF THE RANGE The HPI S range of air/water Inverter heat pumps comes in models of 4.6 to 24.4kW (heating output at +7/+35°C in accordance with the EN 14511-2 standard). They comprise an outdoor unit and a MIT-S indoor unit. AWHP OUTDOOR MODULE TECHNICAL DATA The AWHP 4.5 MR to 27 TR outdoor modules are used in our current split air-to-water ranges. The outdoor module comprises: • a modulating compressor, an aluminium fin heat exchanger • 1 to 2 axial fan(s) (depending on the model) • a liquid separator and power reserve • a 4-way reversal valve • a HP pressure switch and a...

Open the catalog to page 2
HPI-S - 3

MODELS AVAILABLE HPI-S... E MODELS AND HPI-S... H MODELS ADVANCE BACKUP HEAT PUMPS VIA INTEGRATED IMMERSION HEATER Heat pump with electrical backup for heating using radiators and cooling with underfloor heating/ cooling. Heat pump with hydraulic backup via boiler for radiator heating and cooling with underfloor heating/ cooling. 2 OR 6 KW SINGLE-PHASE HPI-S 4.5 MR/E HPI-S 6 MR/E HPI-S 8 MR/E HPI-S 11 MR/E HPI-S 16 MR/E - 4 OR 12 KW THREE-PHASE HPI-S 11 TR/E HPI-S 16 TR/E HPI-S 22 TR/E HPI-S 27 TR/E - HYDRAULIC VIA BOILER (OR WITHOUT BACKUP) HPI-S 4.5 MR/H HPI-S 6 MR/H HPI-S 8 MR/H HPI-S 11...

Open the catalog to page 3
HPI-S - 4

TECHNICAL SPECIFICATIONS HPI-S TECHNICAL SPECIFICATIONS OPERATING TEMPERATURE LIMIT In heating mode: • Water: + 18°C/+ 60°C (+55°C for 4.5-kW model), • Outside air: - 20°C/+ 35°C (- 15°C for 4.5- and 6-kW models) MODEL SEASONAL PERFORMANCES Energy class in heating ERP (35°C) Energy class in heating ERP (55°C) SCOP (35°C/55°C) Seasonal space heating energy efficiency under average temperature (35°C/55°C) * Seasonal space heating energy efficiency under average temperature (35°C/55°C) (with outdoor sensor supplied as standard) CERTIFIED THERMAL PERFORMANCE Heating output at +7°C/+35°C (1)...

Open the catalog to page 4
HPI-S - 5

TECHNICAL SPECIFICATIONS HPI-S WATER TEMPERATURE HPI-S heat pump models can produce hot water up to a temperature of 60°C (55°C for 4.5 kW). The graph shows the water temperature produced for each model based on the outside temperature.

Open the catalog to page 5
HPI-S - 6

TECHNICAL SPECIFICATIONS TABLES FOR SIZING HPI-S 4.5 MR FLOW TEMPERATURE [°C] HEATING 35 40 45 FLOW TEMPERATURE [°C] HEATING 35 40 45 FLOW TEMPERATURE [°C] HEATING 35 40 45 FLOW TEMPERATURE [°C] HEATING 35 40 45

Open the catalog to page 6
HPI-S - 7

TECHNICAL SPECIFICATIONS HPI-S 16 MR/TR FLOW TEMPERATURE [°C] HEATING 35 40 45 FLOW TEMPERATURE [°C] HEATING 35 40 45 FLOW TEMPERATURE [°C] HEATING 35 40 45 These performance levels are not certified, so they should only be used to size the heat pump.

Open the catalog to page 7
HPI-S - 8

MIT-S INDOOR MODULE SPECIFICATIONS MAIN DIMENSIONS (mm AND INCHES) MIT-S 510 KEY ቢ Return 3-way valve circuit Ø G 1 (option) • with HK21 package: internal 3-way valve set or • with HK22 package: adaptation kit for external 3-way valve ባ Flow 3-way valve circuit Ø G 1 (option) • with HK21 package: internal 3-way valve set or • with HK22 package: adaptation kit for external 3-way valve ቤ Direct circuit return G 1" ብ Direct circuit flow G 1" ቦ Gas refrigeration connection: see below ቧ Refrigerant fluid connection: see below ቨ Connection to boiler flow Ø G 1" (MIT-S/H only) ቩ Connection to...

Open the catalog to page 8
HPI-S - 9

TECHNICAL SPECIFICATIONS MIT-S INDOOR MODULE SPECIFICATIONS COMPONENTS • MIT-S /H TR 40L decoupling tank 10L expansion vessel Heating safety valve (3 bar) Interface PCB: electronic boards accessible under the cover E High efficiency heating pump for direct circuit with EEI < 0.23 F Angled DIEMATIC Evolution control panel A B C D G Automatic air vent H High energy efficiency primary circulating pump I Condenser in the form of a stainless steel plate exchanger J Flowmeter K Magnetic filter 10L expansion vessel 40L decoupling tank Heating safety valve (3 bar) Interface PCB: electronic boards...