Solinet : Aluminium flashing systems
24Pages

{{requestButtons}}

Catalog excerpts

Solinet : Aluminium flashing systems - 1

Roof covering Aluminium ashing systems NEW! Solinet 160/50 ands for roong upst ges 12-13 insulation, pa with

Open the catalog to page 1
Solinet : Aluminium flashing systems - 2

Content page Protection of roof covering upstands Flat roofs with slabs on pads Public works Solinet Special bridge and car park 20 - 21 Mechanical fixing of membranes Pitched roof coverings Patented system. Registered trade marks and designs Examples of use are given for information purposes only. In the catalogue, all measurements are given in mm.

Open the catalog to page 2
Solinet : Aluminium flashing systems - 3

Solinet slab-support Description of the system Solinet is the registered trade mark of aluminium ashing systems patented in France and abroad. They are used in the following elds: Solinet slab-support Protection of roof covering upstands Solinet provides protection for roof covering upstands on at roofs. The Solinet range provides a solution to the various circumstances encountered (summary table page 5). Solinet Special bridge and car park For compliant use of the system, the use of the accessories is essential (junction pieces, angle pieces, aluminium protection on a at roof accessible to...

Open the catalog to page 3
Solinet : Aluminium flashing systems - 4

1) The foam at the rear makes good any irregularities and forms a barrier between the roof covering and the gun-applied sealant. 2) Adequate throat with joint backing, allowing the gun-applied sealant to move in three dimensions. 3) Junction sleeves, providing a perfect alignment between units and an effective joint overlap, while leaving an appropriate tolerance for expansion. The proles in the Solinet range are supplied in standard lengths of 3000 mm. They are pre-drilled in the factory every 300 mm. Each 3000 mm length carries dani alu‘s brand name as a mark of guarantee. 4) Angle...

Open the catalog to page 4
Solinet : Aluminium flashing systems - 5

How to choose the right pattern The questions to be asked are: ● Under what circumstances am I? Have I properly analysed my problem? In the event of doubt, call us. Under what accessibility conditions am I? Does the work include a lot of angles to be dealt with, curved sections? In what climate zone is the site located? What overlap or visible height do I need? Have I received the technical supervisor‘s approval of the pattern of Solinet proposed? Does the roof covering upstand include insulation? If yes, what thickness? Outline diagram Section through a Solinet with a double seal at the...

Open the catalog to page 5
Solinet : Aluminium flashing systems - 6

Sample specifications Solinet 10/110 Inaccessible at roof or technical platforms, accessible private and public location, green roof or garden ® Extruded aluminium strip ashing with square-throat and double seal at the head, as manufactured by dani alu (Tel. +33(0)4 78 87 12 48), or technically equivalent. Pattern: Solinet 10/110 for inaccessible at roof or technical platforms (aluminium protection recommended in a public location), green roof or garden, comprising: – pre-drilled extruded prole; – with a square throat; – and provided with 2 factory-prexed gaskets: – a joint backing in the...

Open the catalog to page 6
Solinet : Aluminium flashing systems - 7

– inaccessible at roof or technical platforms; – private accessible at roof; – green roof or garden Ø 7 mm oblong holes every 300 mm Example of use Solinet 15/40 As a replacement for zinc or galvanised strips and concrete llets Scale: 1:1 1 Solinet 15/40 Accessories for Solinet series 15/40 60 2 Junction sleeve 3 Joint backing 4 Gasket at rear 5 Danivit stainless steel xing Ø 6 Internal angle sleeve 6 Silicone sealant 7 Structure 8 Roof covering skirting External angle sleeve Junction sleeve Endpiece

Open the catalog to page 7
Solinet : Aluminium flashing systems - 8

– inaccessible at roof or technical platforms – private accessible at roof – green roof or garden – bendable (if undrilled) – inaccessible at roof or technical platforms – private accessible at roof – green roof or garden – public accessible at roof (with aluminium protection) – bendable (if undrilled) 1 Solinet 10/110 2 Joint backing* 3 Gasket at rear 4 Junction sleeve 5 Aluminium protection 6 Danivit stainless steel xing Ø 6 8 Structure 9 Flat roof covering Ø 7 mm oblong holes every 300 mm 0 0/5 et 1 olin Ø 7 mm oblong holes every 300 mm

Open the catalog to page 8
Solinet : Aluminium flashing systems - 9

*This special joint backing allows the sealant to retain all of its elasticity over time, containing expansion and thus avoiding cracking by torsion. Example of use Solinet 10/50 Scale: 1:1 2 Joint backing* 3 Gasket at rear 4 Junction sleeve 5 Danivit stainless steel xing Ø 6 6 Silicone sealant 7 Structure 8 Roof covering skirting Accessories for Solinet series 10 60 Internal angle sleeve External angle sleeve Junction sleeve

Open the catalog to page 9
Solinet : Aluminium flashing systems - 10

– inaccessible at roof or technical platforms – private accessible at roof – green roof or garden – inaccessible at roof or technical platforms – private accessible at roof – public accessible at roof (with aluminium protection) – green roof or garden Example of use Solinet 20/100 Scale: 1:1 1 Solinet 20/100 5 7 2 Joint backing 3 Gasket at rear 4 Junction sleeve 5 Aluminiumprotection (recommended on a at roof accessible to the public) 6 Danivit stainless steel xing Ø 6 Ø 7 mm oblong holes every 300 mm 8 Structure 9 Flat roof covering 9 Ø 7 mm oblong holes every 300 mm

Open the catalog to page 10
Solinet : Aluminium flashing systems - 11

Example of use Solinet 20/60 Scale: 1:1 1 Solinet 20/60 2 Joint backing 4 Junction sleeve 5 Danivit stainless steel xing Ø 6 6 Silicone sealant 7 Structure 8 Flat roof covering Accessories for Solinet series 20 80 Internal angle sleeve External angle sleeve Junction sleeve End piece

Open the catalog to page 11
Solinet : Aluminium flashing systems - 12

Solinet 40/50 Solinet 60/50 Solinet 160/50 – inaccessible at roof or technical platforms – public accessible at roof (with aluminium protection) – planted roof or garden – inaccessible at roof or technical platforms – private accessible at roof – planted roof or garden Ø 7 mm oblong ong holes ever very 300 mm 0 Example of use Solinet 15/50 Scale: 1:1.25 2 Joint backing 3 Gasket at rear 4 Junction sleeve 5 Danivit stainless steel xing Ø 6 6 Silicone sealant 7 Structure 8 Flat roof covering 50

Open the catalog to page 12
Solinet : Aluminium flashing systems - 13

Example of use Solinet 100/50 Scale: 1:1.25 4 1 Solinet 100/50 2 Joint backing 3 Gasket at rear 4 Junction sleeve 6 Danivit stainless steel xing Ø 6 7 Silicone sealant 8 Structure 9 Insulation 10 Flat roof covering Accessories for Solinet series 50 Size of angles Solinet 15/50 Solinet 40/50 Solinet 60/50 Solinet 100/50 Solinet 160/50 Internal angle sleeve External angle sleeve Junction sleeve Endpiece

Open the catalog to page 13

All Dani alu catalogs and technical brochures

  1. Sherpal®

    4 Pages

  2. Iteal

    8 Pages

  3. Couvernet®

    12 Pages

  4. Dilat®

    4 Pages

  5. Ancral

    2 Pages

  6. Barnet

    4 Pages

  7. Dallnet-C

    8 Pages

  8. dallnet-g

    8 Pages

  9. Dallnet-O

    4 Pages

  10. Dallnet-R

    2 Pages

  11. Helial-D

    2 Pages