Catalog excerpts
ENGINEERING TOMORROW Data sheet Temperature transmitter MBT 9110 MBT 9110 transmitter with box enclosure Standard transmitter: D Galvanic isolated transmitter: E MBT 9110 transmitter for B-head High cap for integration with B-head temperature sensor. Standard transmitter: A Galvanic isolated transmitter: B The MBT 9110 temperature transmitter can be used for converting the Pt 100 / Pt 1000 ohm signal or the thermo couple mV signal to a 4 - 20 mA signal. The MBT 9110 is a very durable and reliable temperature transmitter with all major marine approvals and can be used together with all our sensors based on Pt or Thermocouple technology. MBT 9110 transmitters in the standard program are delivered in an enclosure, but are also used as an integrated part of certain temperature sensors. The transmitter is available as standard or galvanic isolated with or without EEx approval. MBT 9110 transmitter as terminal block Standard transmitter: G Galvanic isolated transmitter: H 2-wire universal transmitter for industrial and maritime applications Pt 100, Pt 1000 or thermocouple input 4 - 20 mA standard output - with or without galvanic isolation • For mounting in DIN B connection head, heightened lid or in a separate enclosure • Advanced sensor fault indication • Temperature linearized Lloyds Register of Shipping, LR Germanischer Lloyd, GL Det Norske Veritas, DNV Nippon Kaiji Kyokai, NKK China Classification Society, CCS Bureau Veritas, BV
Open the catalog to page 1Data sheet Temperature transmitter, type MBT 9110 Primary accuracy Kamb = Ambient temperature change Electrical specifications
Open the catalog to page 2Data sheet Temperature transmitter, type MBT 9110 Type MBT 9110 Application Marine Size Standard Sensor element Pt 100 resistance element Thermocouple, Type K, NiCr-Ni Pt 1000 resistance element Other Transmitter setting, end of range 0 °C (or none) 1. digit defines 100's 2. digit defines 10's Examples : Temperature range 220 °C = 22 Temperature range 150 °C = 15 Other Connections 2 wires 3 wires') 4 wires Transmitter setting, start of range 0 None Transmitter type: As terminal block Standard Galvanically isolated In hightened lid Standard Galvanically isolated In Box enclosure Standard...
Open the catalog to page 3Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Open the catalog to page 4All DANFOSS catalogs and technical brochures
-
MCX15B
6 Pages
-
Online Grocery
3 Pages
-
TP5000 Si Range
4 Pages
-
ECL Comfort 110
2 Pages
-
CANopen & SAE J1939
6 Pages
-
MBT 5111
4 Pages
-
ADAP-KOOL® System Managers
6 Pages
-
PLUS+1®
2 Pages
-
MBC 8000 and MBC 8100
5 Pages
-
MBT 3560
4 Pages
-
MBT 3270
8 Pages
-
CANopen & SAE J1939
6 Pages
-
Danfoss Link & Heat Pump KIT
2 Pages
-
FEV-Z climate sensor
4 Pages
-
SpeedUp Heat Panels
2 Pages
-
ECtemp Next / Next Plus
3 Pages
-
Danfoss Heat Pumps
24 Pages
-
TP9000
2 Pages
-
Electronic Room Controls
1 Pages
-
Danfoss Brochure
12 Pages
-
Danfoss Link™
2 Pages
-
RMT
2 Pages
-
FP735Si
2 Pages
-
FP975
16 Pages
-
Outdoor Heating
1 Pages
-
Electric Floor Heating
1 Pages
-
ComLynx Datalogger
2 Pages
-
Avoid mold and energy waste
8 Pages
-
DEVIlink
2 Pages
-
Ground Voltage Control
2 Pages
-
Danfoss Solar Inverters
4 Pages