1. Catalogs
  2. DANFOSS
  3. Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss

Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss

Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss
1 / 124 PagesView full catalog

Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss

Product catalog summary
Overview: This document is a comprehensive catalogue of hermetic compressors for DC voltage, manufactured by Secop for Danfoss. It covers a wide range of compressors suitable for various applications, including mobile refrigeration in vehicles, boats, and solar-powered systems.
Part I: BD Compressors – Product Range
  • Product Range: The catalogue lists various BD compressors, including BD35F, BD50F, BD80F, BD150F, BD250GH.2, BD350GH, and BD220CL, each with specific applications and capacities.
  • Electronics Units & Applications: Details on electronic units compatible with different compressors, highlighting their voltage requirements and code numbers.
  • Tool4Cool® Software: A PC software tool for configuring compressors to optimize performance.
Part II: Application Examples
  • Mobile Applications: Examples include comfort cooling in trucks, maritime appliances, recreational vehicles, and portable cooling boxes.
  • Specialized Applications: Includes solar-assisted cooling, telecom cooling to increase battery lifetime, and mobile refrigeration in cars and buses.
Part III: DC Compressors Basics
  • Technical Data: Provides detailed technical specifications for electronic units, including housing and features.
  • Design Considerations: Discusses preconditions for long operating life, design limits, moisture and impurities management, and refrigerant charge limits.
  • Installation Guidelines: Instructions on mounting compressors and accessories, shipment positions, and conversions.
Appendix: Contains data sheets for detailed specifications of each compressor model.
Key Specifications:
  • Refrigerants: R134a, R404A/R507, R600a, R290.
  • Capacity Range: Varies by model, with specific capacities listed for different evaporating temperatures.
  • Power Consumption: Detailed power consumption data at maximum speed for each compressor model.
Critical Information:
  • Applications: Compressors are suitable for a wide range of mobile and stationary applications, including trucks, boats, buses, and solar-powered systems.
  • Compatibility: Each compressor model has specific electronic units and code numbers for proper configuration and operation.
Overview: The document provides detailed specifications and descriptions of various hermetic compressors and electronic units manufactured by Secop for Danfoss. These components are designed for use in mobile refrigeration and cooling systems, particularly in vehicles and telecommunication applications.
Key Sections:
  • Product Specifications: The document lists various models of compressors and electronic units, including their code numbers, voltage requirements, and specific features such as speed settings, battery protection, and compatibility with solar panels.
  • Compressor Models: Models like BD35F, BD50F, BD80CN, BD250GH.2, and BD350GH are highlighted, each with specific applications such as mobile refrigeration, telecommunication cooling, and comfort cooling in trucks.
  • Electronic Units: These units are equipped with features like adaptive energy optimization, speed settings, and battery protection. They are available in different configurations to suit various compressor models.
  • Accessories: The document details accessories such as remote kits, AC line cords, temperature sensors, and communication cables, which support the installation and operation of the compressors and electronic units.
  • Software Tools: The Tool4Cool® LabEdition software is mentioned as a free tool for optimizing compressor performance.
  • Applications and Benefits: The compressors are designed for silent operation, high efficiency, and adaptability to different power supplies. They are suitable for use in environments without a stable power supply, such as solar-powered systems, and are optimized for energy savings and reliability.
Critical Information:
  • Energy Efficiency: The compressors feature low energy consumption, making them ideal for use with solar energy and reducing the need for additional batteries.
  • Durability and Reliability: Designed to withstand vibrations and harsh conditions, these compressors are suitable for mobile applications and have a long design lifetime.
  • Advanced Features: The electronic units include advanced features like electronic thermostats, fan speed control, and battery protection to enhance performance and safety.
Conclusion: Secop's compressors and electronic units offer versatile and efficient solutions for mobile refrigeration and cooling applications, with a focus on energy efficiency, reliability, and adaptability to various power sources.
Overview: The document provides a detailed description of the BD compressor series, designed for various applications including maritime, recreational vehicles, trucks, medical transport, and solar-assisted cooling. These compressors are manufactured by Secop for Danfoss and are tailored for DC voltage applications.
Key Features and Benefits:
  • High Efficiency and Energy Saving: The compressors operate with low current consumption, allowing for energy savings and the use of smaller batteries. They feature variable speed and capacity to adapt to cooling requirements.
  • Global Compatibility: The compressors can be powered by direct 12/24 V DC supply, making them suitable for global use.
  • Advanced Control and Communication: Equipped with Modbus communication connection, electronic thermostats, and alarm/event logs for easy error identification and servicing.
  • Noise Reduction: Fan speed control and start/stop delays reduce noise, especially beneficial during nighttime.
  • Battery Protection: Advanced functions prevent battery drainage to destructive levels, ensuring safety and reliability.
  • Durability and Stability: Designed to withstand vibrations, shocks, and harsh conditions, with a design lifetime of 10 years.
Specific Applications:
  • Maritime Appliances: The compressors are designed to resist sea conditions and are suitable for refrigeration in boats, covering capacities from 20 to 180 Watts.
  • Recreational Vehicles (RVs): Suitable for use in RVs, these compressors offer silent operation and are capable of handling changeable climatic conditions.
  • Trucks: Tailored for truck use, these compressors can be integrated into the cab, providing reliable cooling under harsh road conditions.
  • Medical Transport: Ensures temperature-controlled transportation of medicines and vaccines, maintaining a constant temperature range of -18°C to +8°C.
  • Solar-Assisted Cooling: Designed for areas with poor or no power supply, these compressors can operate on solar power, making them ideal for remote locations.
Conclusion: The BD compressor series offers versatile, efficient, and reliable cooling solutions across various sectors, with advanced features that enhance performance and reduce operational costs.
Introduction
The document discusses the features and benefits of BD compressors, specifically designed for portable cooling solutions in various applications such as cars, vans, and buses. These compressors are manufactured by Secop for Danfoss and are ideal for mobile refrigeration due to their compact size, efficiency, and adaptability to different power sources.
Specifications
The BD35F compressor is highlighted for its suitability in portable cooling boxes, operating on 12 and 24 V DC power supplies with a capacity range of 20 to 130 W. It supports low and medium back pressure applications and is compatible with cooling boxes ranging from 18 to 150 liters. The compressor includes an electronic unit for easy installation and operation.
Features and Benefits
  • Universal Power Supply: Compatible with 12/24 V DC, allowing global use.
  • Energy Efficiency: Low current consumption and variable speed/capacity for energy savings.
  • Advanced Battery Protection: Ensures the battery is not drained, providing a safe start every time.
  • Modbus Communication: Allows for custom control box creation and remote monitoring.
  • Electronic Thermostat: Reduces costs by eliminating the need for additional thermostats.
  • Alarm & Event Logs: Facilitates quick error identification and servicing, reducing service costs.
Applications
Mobile Refrigeration in Cars: The BD1.4F-AUTO and BD1.4F-VSD compressors are designed for in-car use, offering a compact and lightweight solution with low noise levels. They are ideal for 10-15 liter cabinets, providing efficient cooling with minimal space usage.
Mobile Refrigeration in Buses: These compressors are suitable for buses, offering robust performance under varying climatic conditions and vibrations. They support refrigerator sizes up to 30-50 liters with freezer compartments.
Technical Features
  • High COP: Direct DC power supply ensures better efficiency and reduced failure modes compared to AC solutions.
  • Fan Speed Control: Allows for noise reduction and cost savings through less wiring and installation costs.
  • Compliance: Meets EMI standards, ensuring compatibility with automotive requirements.
Conclusion
The BD compressors provide a versatile and efficient solution for mobile refrigeration needs, offering significant energy savings, ease of installation, and adaptability to various power sources. They are particularly beneficial for applications requiring mobility and flexibility, such as in cars and buses.
1. VDE/UL Approved Compressor - Electronic Unit Combinations
This section outlines the approved combinations of compressors and electronic units, ensuring compliance with VDE and UL standards.
2. Electronic Units - Technical Data
Technical specifications for electronic units are provided, detailing operational parameters and compatibility.
3. Electronic Units - Housings
Describes the design and material specifications for the housings of electronic units.
4. Electronic Units - Features
This section covers various features of electronic units, including voltage ranges, cable dimensions, compressor speed control, thermostat connections, and energy optimization functions. It also discusses fan connections, lamp connections, fault detection, overload protections, and battery protection.
5. Preconditions for Long Operating Life
Outlines conditions necessary to ensure the longevity of the compressors, focusing on motor and thermal overload protections.
6. Design Limits
Specifies the operational limits regarding coil and condensing temperatures to ensure safe and efficient compressor performance.
7. Moisture and Impurities
Discusses the importance of selecting appropriate filter driers to manage moisture and impurities in the system.
8. Condition at Delivery / Warnings
Provides guidelines on the condition of compressors upon delivery and associated warnings for safe handling.
9. Max. Refrigerant Charge
Details the maximum allowable refrigerant charge for safe and efficient operation.
10. Conversions
Information on converting systems to use different refrigerants, emphasizing the importance of using the correct type and amount.
11. Mounting the Compressor
Instructions for properly mounting compressors, including connector positions.
12. Mounting Accessories
Lists accessories available for mounting compressors and their proper use.
13. Shipment Positions
Guidelines for the correct positioning of compressors during shipment to prevent damage.
Hermetic Compressors for DC Voltage
Secop compressors for Danfoss are designed for variable speed and direct current applications, suitable for mobile and stationary uses. They support various refrigerants, including R134a, R404A, and R507, and are compliant with environmental regulations. Special versions are available for specific applications like buses and trucks, designed to minimize noise and withstand shock and vibration.
Refrigerant Transition and Environmental Compliance
Discusses the transition from CFC and HCFC refrigerants to more environmentally friendly options like HFCs and hydrocarbons, in compliance with the Montreal Protocol. Emphasizes the importance of using the correct refrigerant type and charge for system efficiency and environmental safety.
Refrigerants and Handling: The document specifies the use of 3 Angstrom Molecular Sieves in FC refrigeration systems. It covers various refrigerants, including HFC refrigerants like R134a, and hydrocarbons such as R600a and R290, which are flammable and require compliance with EN/IEC 60335-2-24 standards. Proper training for handling these refrigerants is emphasized, and conversions from non-flammable to flammable refrigerants are prohibited.
Compressor Specifications: Secop compressors for Danfoss are designed for DC voltage applications and can use capillary tubes or TEV as throttling devices. They are equipped with features like overload protection, battery protection, and fan control. The compressors are quiet, with high COP values, and can operate under various conditions, including temporary inclines.
Flammable Refrigerants: R600a and R290 have specific flammability limits and ignition temperatures. Handling requires specialized training and equipment, and soldering is not allowed on systems using these refrigerants.
Compressor Denomination: The denomination system indicates compressor series, displacement, refrigerant type, application range, and special features. Different letters and numbers provide detailed information about the compressor's capabilities and intended use.
Labeling and Approvals: The document details the labeling system for compressors and electronic units, including information on approvals, voltage, and application. It also covers the date code format and country of origin labeling, with examples provided for Slovakia and China.
Technical Data: The document includes extensive technical data on electronic units, including supply voltage ranges, ambient temperature limits, and connectivity options. It also lists approved combinations of compressors and electronic units, highlighting those with VDE and UL approvals.
Overview: This document provides technical specifications and operational guidelines for hermetic compressors designed for DC voltage, manufactured by Secop for Danfoss. It covers electronic units, communication interfaces, and various features such as Adaptive Energy Optimization (AEO) and ECO functions.
Specifications:
  • Bus Communication: Supports 1 wire, LIN, and Modbus protocols.
  • Lighting: LED indicators are used for alarms.
  • Setpoint Selection: Options include mechanical thermostats, external resistors, and TOOL4COOL® software.
  • Voltage Range: DC supply voltage ranges from 9.6V to 60V, with AC options available.
  • Environmental Conditions: Operating temperature up to 55°C, storage temperature from -40°C to 85°C.
  • Enclosure and Weight: IP Class 20 or 42, with weights varying from 0.11 kg to 0.43 kg.
Procedures:
  • Installation: Electronic units must be connected directly to battery poles or power supply terminals, with an external fuse for protection.
  • Voltage Calibration: Units calibrate to 12V or 24V systems based on detected voltage.
  • Startup Conditions: Compressors start at low speed and ramp up based on load, with specific RPM settings for different models.
Features:
  • Compressor Speed Control: Speed can be adjusted via external resistors or TOOL4COOL® software.
  • Thermostat Connection: Supports both mechanical and electronic thermostats, with options for no standby power consumption.
  • Adaptive Energy Optimization (AEO): Adjusts compressor speed to prevent short cycling and optimize energy use.
  • ECO Function: Reduces energy consumption and noise, available in units with bus communication interfaces.
Recommendations:
  • Ensure correct cable dimensions to minimize voltage drop.
  • Use TOOL4COOL® software for advanced configuration and monitoring.
  • Follow specific instructions for each electronic unit model for optimal performance.
Electronic Unit Specifications:
Various electronic units are manufactured by Secop for Danfoss, each with specific code numbers and fan output specifications. Units like 101N0210, 101N0220, and others have a fan output of 6 Watts at 12V, while units like 101N0715 offer 60/40 Watts at 12 or 24V.

Lamp Connection:
A 12V DC 5 Watt lamp can be connected between terminals A and C on specific units, with a regulated output voltage of 12V DC. The lamp output can supply a continuous current of 0.5A.

Fault Detection and Diagnosis:
LED indicators are used for diagnosing compressor issues, with specific flash patterns indicating errors such as low battery voltage, fan overload, motor start error, and high PCB temperature. The Tool4Cool® software interface provides detailed alarm messages.

Overload Protections:
Electronic units have built-in temperature sensors to prevent overheating. If the PCB temperature exceeds 100°C, the compressor stops until it cools below 90°C.

Battery Protection:
Battery protection functions are included to prevent damage from heavy discharge. Standard and optional settings are available, with specific cut-out and cut-in voltage levels for different units.

Mounting Instructions:
Instructions for mounting electronic units on compressors are provided, including the use of remote kits for specific models.

Preconditions for Long Operation Life:
To ensure long compressor life, sufficient starting and breakdown torque, low operating temperatures, and cleanliness are essential. Proper motor and refrigerant selection are crucial.

Design Limits:
Design criteria include maintaining low coil and condensing temperatures to protect the compressor and extend its life. Specific temperature limits are provided for different refrigerants and applications.
Moisture Level and Measurement Method: The document discusses the acceptable moisture levels in compressors, stating that levels between 200 and 250 ppm are not critical. The measurement method involves assessing total moisture in the air volume, with equilibrium reached within 24 hours. A limit of 125 ppm is considered low compared to surrounding air moisture levels.
Test Parameters: The document specifies test conditions including a 24-hour conditioning period at room temperature, with measurements taken using an electrical hydrometer. The demand is a maximum of 125 ppm H2O.
Filter Drier Selection: Only manufacturer-approved filter driers for mobile applications should be used to prevent wear and damage. Recommended materials include molecular sieves with 3 Å pores for various refrigerants.
Condition at Delivery and Warnings: Compressors are delivered without starting devices and must be handled carefully to avoid damage. They are charged with dried and degassed oil, and specific oils and refrigerants are approved for use. High potential tests are conducted before delivery, and anti-freeze agents should not be used.
Refrigerant Charge Limitations: The document outlines the maximum permissible refrigerant charges for different compressor types and emphasizes the importance of not exceeding these limits to prevent damage.
Conversions: Guidelines for converting systems from R12 to alternative refrigerants like R134a, R290, and R404A/R507 are provided, including the use of specific driers and adherence to cleanliness standards.
Mounting the Compressor: Instructions for mounting compressors, including connector positions and the use of specific mounting accessories, are detailed. Proper orientation during shipment is also discussed to prevent damage.
Overview: This document provides detailed specifications and operational guidelines for various models of hermetic compressors designed for DC voltage applications, manufactured by Secop for Danfoss. It includes information on different refrigerants such as R134a, R600a, R290, and R404A/R507, and covers models like BD35K, BD80CN, BD100CN, and BD220CL.
Specifications:
  • BD1.4F-AUTO Compressor: Designed for R134a refrigerant, operates on 12V DC. Key specifications include a voltage range of 8.5 - 17 VDC, maximum condensing temperature of 60°C, and a motor speed of 3,000 rpm. The compressor has a displacement of 1.41 cm³ and uses polyolester oil.
  • BD1.4F-FSD Compressor: Supports both DC (12-24V) and AC (100-240V) operations. It features a permanent magnet, brushless DC motor with a fixed speed of 3,000 rpm. The voltage range for DC is 9.6 - 17 VDC and 19 - 34 VDC, while for AC it is 100 - 240 V/50-60 Hz.
  • BD1.4F-VSD Compressor: Similar to the FSD model but with variable speed capabilities. It supports a wider evaporating temperature range from -30 to 15°C and is suitable for LBP, MBP, and HBP applications.
Performance Data:
  • Performance metrics are provided under different standards such as EN 12900 and ASHRAE LBP, detailing capacity, power consumption, and COP across various evaporating temperatures.
  • For example, under EN 12900, the BD1.4F-AUTO compressor shows a capacity range from 14.3 W at -25°C to 108 W at 5°C, with corresponding power consumption and COP values.
Operational Errors:
  • Error codes are provided for troubleshooting, including communication failure, thermostat failure, thermal cut-out, motor speed errors, and battery protection cut-out.
  • These errors can be diagnosed using the TOOL4COOL® software or indicated by LED flashes.
Accessories and Installation:
  • Details on mounting accessories, wire dimensions, and connectors are provided for proper installation and operation.
  • Standard battery protection settings are outlined, with specific cut-out and cut-in voltage values for both 12V and 24V operations.
General Notes:
  • Secop reserves the right to alter product specifications without notice, and all trademarks are the property of their respective companies.
  • The document emphasizes the importance of adhering to specified cooling requirements and operational guidelines to ensure optimal performance and longevity of the compressors.
Overview: This document provides detailed technical specifications and performance data for the BD1.4F-VSD and BD1.4F-VSD-HD hermetic compressors manufactured by Secop for Danfoss. These compressors are designed for use with R134a refrigerant and operate on 12-24V DC and 100-240V AC power supplies.
Specifications:
  • Model: BD1.4F-VSD and BD1.4F-VSD-HD
  • Refrigerant: R134a
  • Voltage Range: 9.6 - 17 VDC / 19 - 34 VDC / 100 - 240 VAC
  • Max Condensing Temperature: 60°C continuous, 70°C short-term
  • Max Winding Temperature: 125°C continuous, 135°C short-term
  • Motor Type: Permanent magnet, brushless DC
  • Displacement: 1.41 cm³
  • Oil Type: Polyolester
  • Weight: Compressor 2.1 kg, Electronic unit 0.11 kg
Performance Data:
  • Cooling Capacity: Varies with RPM and temperature, detailed in tables for both EN 12900 and ASHRAE LBP standards.
  • Power Consumption: Detailed in tables, varies with RPM and temperature.
  • Current Consumption: Provided for 12V DC, with a note that values should be halved for 24V applications.
  • COP (Coefficient of Performance): Provided for both EN 12900 and ASHRAE LBP standards, varies with RPM and temperature.
Accessories:
  • Bolt joints, snap-on connectors, and terminal covers are available with specific code numbers.
  • Automobile fuses and main switches are specified for 12V and 24V operations.
Operational Errors: The document lists potential error codes and their meanings, such as thermostat failure, thermal cut-out, and motor start errors, which can be diagnosed using the TOOL4COOL® software.
Test Conditions: The compressors are tested under specific conditions as per EN 12900 and ASHRAE LBP standards, with specified condensing, ambient, and suction gas temperatures.
Design and Dimensions: Detailed dimensions and connector specifications are provided, including material and tolerance information.
Remarks: The document notes that the HD version of the compressor is designed to handle extreme vibrations and provides contact information for further inquiries.
Overview: This document provides detailed specifications and operational guidelines for the BD1.4F-VSD-HD and BD35F hermetic compressors, designed for DC voltage applications. These compressors are manufactured by Secop for Danfoss and are suitable for various cooling applications.
Specifications:
  • BD1.4F-VSD-HD: Operates with R134a refrigerant, supports 12-24V DC, and is designed for heavy-duty applications. It features a permanent magnet, brushless DC motor with variable speed.
  • BD35F: Compatible with R134a, supports 12-24V DC, 10-45V DC solar, and 100-240V AC. It includes a variable speed motor and is suitable for low, medium, and high back pressure applications.
Cooling Requirements: Both compressors require static cooling under normal conditions, with fan cooling necessary at higher ambient temperatures.
Operational Guidelines:
  • Voltage range for BD1.4F-VSD-HD is 9.6 - 17 VDC and 19 - 34 VDC, while BD35F supports a wider range including AC and solar applications.
  • Standard battery protection settings are provided, with cut-out and cut-in voltage values specified for both 12V and 24V operations.
Performance Data:
  • Capacity, power consumption, and efficiency metrics are provided for various RPMs and temperatures, highlighting the compressors' performance under different conditions.
  • Efficiency is measured in terms of EER (Energy Efficiency Ratio) and COP (Coefficient of Performance).
Error Codes: The document lists potential operational errors, such as thermostat failure and motor start errors, along with their corresponding LED flash codes.
Accessories: Various accessories are available, including bolt joints, terminal covers, and remote kits, with specific code numbers for ordering.
Design and Dimensions: Detailed dimensions and connector specifications are provided for installation and integration purposes.
Notes: Secop reserves the right to alter product specifications without notice, and all trademarks are acknowledged as the property of their respective owners.
Overview: This document provides technical specifications and operational details for hermetic compressors designed for DC voltage, specifically models manufactured by Secop for Danfoss. It includes information on materials, dimensions, performance metrics, and operational guidelines.
Specifications:
  • Materials: The connectors are made of Cu-plated steel with Al caps.
  • Dimensions: Various connector locations and angles are specified, with tolerances provided for precision.
  • Compressor Models: Models include BD35F-HD and BD35F-B, optimized for different applications such as heavy-duty and bus-optimized environments.
Performance Metrics:
  • Capacity: Detailed capacity data is provided in both BTU/h and watts across different RPMs and temperatures, following ASHRAE LBP and EN 12900 standards.
  • Power and Current Consumption: Power consumption is detailed in watts, and current consumption is provided for both 12V and 24V applications.
  • Efficiency: Efficiency metrics are given as EER (BTU/Wh) and COP (W/W) for various conditions.
Operational Guidelines:
  • Voltage Range: The compressors operate within a DC voltage range of 9.6 - 17 V and 21.3 - 31.5 V, and an AC range of 100 - 240 V at 50/60 Hz.
  • Cooling Requirements: Static cooling is generally sufficient, with fan cooling recommended under certain conditions.
  • Error Codes: The document lists potential operational errors indicated by LED codes, such as thermal cut-out and motor start errors.
Accessories and Approvals:
  • Accessories: Various accessories are listed, including bolt joints and remote kits.
  • Approvals: The compressors have UL, e4, and C-Tick approvals.
Additional Notes: Secop reserves the right to alter product specifications without notice and disclaims responsibility for errors in printed materials. The document emphasizes the importance of adhering to specified operational conditions to ensure optimal performance.
General Overview:
The document provides technical specifications for Danfoss direct current compressors, specifically models BD80F, BD150F, and BD250GH. These compressors are designed for use with R134a refrigerant and operate on 12-24V DC power.

BD80F Specifications:
  • Code number: 101Z0280
  • Electronic unit: High Speed 101N0290
  • Application: Low Back Pressure (LBP)
  • Evaporating temperature range: -30 to -5°C
  • Voltage range: 9.6 - 17 VDC / 21.3 - 31.5 VDC
  • Max condensing temperature: 60°C continuous, 70°C short
  • Motor type: Variable speed
  • Displacement: 3.00 cm³
  • Oil quantity: 150 cm³ (polyolester)
  • Weight: 4.4 kg (compressor), 0.32 kg (electronic unit)

BD150F Specifications:
  • Code number: 102G4784
  • Electronic unit: 105N4220
  • Application: LBP
  • Evaporating temperature range: -35 to -10°C
  • Voltage range: 160 - 254 VAC, 50-60Hz
  • Max condensing temperature: 60°C continuous, 70°C short
  • Motor type: Permanent magnet
  • Displacement: 6.49 cm³
  • Oil quantity: 180 cm³ (polyolester)
  • Weight: 7.9 kg (compressor), 0.6 kg (electronic unit)

BD250GH Specifications:
  • Code number: 101Z0406
  • Electronic unit: High Speed 101N0290
  • Application: LBP/MBP/HBP
  • Evaporating temperature range: -25 to 15°C
  • Voltage range: 9.6 - 17 VDC / 21.3 - 31.5 VDC
  • Max condensing temperature: 60°C continuous, 70°C short
  • Motor type: Variable speed
  • Displacement: 2.50 cm³
  • Oil quantity: 150 cm³ (polyolester)
  • Weight: 4.4 kg (compressor), 0.32 kg (electronic unit)

Performance Data:
  • Capacity and power consumption are provided for various RPMs and temperatures, with detailed tables for each model.
  • Coefficient of Performance (COP) values are given for different conditions, indicating efficiency.

Cooling Requirements:
  • Static cooling is generally sufficient for all models at specified ambient temperatures.
  • Fan cooling may be necessary under certain conditions.

Operational Errors:
  • Error codes are provided for diagnosing issues such as thermal cut-out, motor speed errors, and battery protection cut-out.

Accessories:
  • Various accessories are listed, including bolt joints, snap-ons, and remote kits.

Remarks:
  • Secop reserves the right to alter products without notice.
  • All trademarks are property of their respective companies.
Overview: This document provides technical specifications and operational guidelines for the BD350/350GH Direct Current Twin Compressor, manufactured by Secop for Danfoss. It includes details on performance metrics, electrical components, operational errors, and accessories.
Specifications:
  • Compressor Type: Hermetic Compressors for DC Voltage, R134a refrigerant.
  • Voltage: Available in 12V and 24V DC versions.
  • Evaporating Temperature Range: -25°C to 15°C.
  • Voltage Range: 12V DC (9.6 - 17 VDC), 24V DC (19 - 31.5 VDC).
  • Max Condensing Temperature: 60°C continuous, 70°C short-term.
  • Cooling Requirements: Fan cooling (F1) is necessary at various ambient temperatures.
Performance Metrics:
  • Capacity: Detailed in watts for different RPMs and temperatures, both under EN 12900/CECOMAF and ASHRAE LBP standards.
  • Power and Current Consumption: Provided for various RPMs and temperatures.
  • COP (Coefficient of Performance): Values given for different RPMs and temperatures, indicating efficiency.
Electrical Components:
  • Various cables and sensors are listed with code numbers for ordering.
  • Includes details on mounting accessories and communication interfaces.
Operational Errors:
  • Error codes are provided for issues such as thermostat failure, thermal cut-out, motor speed errors, and battery protection cut-out.
  • Errors can be diagnosed using the TOOL4COOL® software.
Design and Dimensions:
  • Compressor displacement is 2 x 5.08 cm³ with a weight of 15.8 kg.
  • Connector dimensions and materials are specified.
Remarks:
  • Secop reserves the right to alter products without notice.
  • All trademarks are property of their respective companies.
See more

Catalog excerpts

Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-1

Hermetic Compressors For DC Voltage R134a | R404A | R507 | R290 | R600a 12/24/48 The widest range of direct current compressors

 Open the catalog to page 1
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-2

Hermetic Compressors for DC Voltage Part 1 BD Compressors - Product range TOOL COOL Flexible control settings TOOL4COOL® Software Tool4Cool® is a unique PC software tool that enables you to precisely configure your Secop compressors produced for Danfoss to your cooling systems. Via microprocessor-based controllers, Tool4Cool® gives you easy access to all parameters. These can be changed, monitored, downloaded or uploaded to get the optimum performance out of your cooling system. Please visit www.secop.com/tool4cool.html for more information. FRCC.PK.047.A2.02 - Manufactured by Secop for Danfoss...

 Open the catalog to page 2
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-3

Hermetic Compressors for DC Voltage Modern comfort is brought into life when leaving home. As people go mobile, so does food. The excellent performance of the BD series safeguards food preservation. With our outstanding DC compressors for cars, vans, boats, trucks, etc., Secop compressors produced for Danfoss has transcended the barriers for mobile refrigeration. **** Please refer to the individual compressor data sheets for the complete application range. Capacity [W] at max. speed **** EN12900 Household/CECOMAF | ASHRAE Evaporating temperature [°C] -40 Power consumption [W] at max. speed ****...

 Open the catalog to page 3
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-4

Hermetic Compressors for DC Voltage Electronic units & Applications FRCC.PK.047.A2.02 - Manufactured by Secop for Danfoss

 Open the catalog to page 4
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-5

BD1.4F-AUTO and BD1.4F-VSD/-FSD R134a, -30°C, +5 and +15 / 0°C evap. temp. In-car cabinets and all mobile applications for portable boxes, boats, trucks etc., 14-108 W and 7-218 W / 5-85 W cooling capacity*. BD80/100CN R290, -40°C, -10°C evap. temp. Stationary freezer application (not approved for vehicles), solar-powered systems, ice cream boxes up to 200 l, 20-164 W / 31-209 W cooling capacity*. BD35K R600a, -30°C, +10°C evap. temp. Stationary application, solar-powered vaccine coolers etc., 100-200 l coolers, 13-128 W cooling capacity*. BD150F R134a, -35°C, -10°C evap. temp. The BD150F compressor...

 Open the catalog to page 5
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-6

Hermetic Compressors for DC Voltage FRCC.PK.047.A2.02 - Manufactured by Secop for Danfoss

 Open the catalog to page 6
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-7

Hermetic Compressors for DC Voltage Description standard compressor, mm tube connectors same as 101Z0200, inch tube connectors optimized for rough vehicle motions (especially in buses), mm tube connectors heavy duty version which can handle extreme vibrations, mm tube connectors for stationary use only, mainly solar applications, mm tube connectors standard compressor, mm tube connectors same as 101Z1220, inch tube connectors standard compressor, mm tube connectors standard compressor, mm tube connectors, TL - based, 12/24 V DC with inverter mm tube connectors, HBP compressor mm tube connectors,...

 Open the catalog to page 7
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-8

Hermetic Compressors for DC Voltage Code numbers BD250GH.2 | BD350GH with 101N07xx series controllers FRCC.PK.047.A2.02 - Manufactured by Secop for Danfoss

 Open the catalog to page 8
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-9

Hermetic Compressors for DC Voltage Code number for telecommunication applications (battery cooling) for cooling and comfort cooling in trucks and vans for telecommunication applications (battery cooling) for cooling and comfort cooling in trucks and vans Temperature sensor, 470 mm, spade connectors Temperature sensor, 1000 mm, spade connectors BD350GH 48 V DC supply BD350/350GH 24 V DC supply - twin compressor Electronic unit 48 V DC Industrial-Pack (I-Pack) Temperature sensor, 1500 mm, spade connectors Secop One Wire/LIN gateway with cables & driver Communication cable, 1500 mm, AMP connector...

 Open the catalog to page 9
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-10

Hermetic Compressors for DC Voltage Code numbers BD350GH | BD220CL with 101N08xx series controllers

 Open the catalog to page 10
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-11

Hermetic Compressors for DC Voltage for cooling and comfort cooling in trucks and vans BD350/350GH 12 V DC supply - twin compressor for cooling and comfort cooling in trucks and vans for cooling and comfort cooling in trucks and vans BD350/350GH 24 V DC supply - twin compressor for cooling and comfort cooling in trucks and vans for mobile refrigeration units (boxes, containers, trolleys) Electronic unit (compressor module) 12 V DC Code number electronic module (to be used together with 101N0820) Electronic unit (compressor module) 24 V DC electronic module (to be used together with 101N0820)...

 Open the catalog to page 11
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-12

Hermetic Compressors for DC Voltage FRCC.PK.047.A2.02 - Manufactured by Secop for Danfoss

 Open the catalog to page 12
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-13

Hermetic Compressors for DC Voltage Code number automotive compressor, mm tube connectors variable speed drive compressor, mm tube connectors same as 109Z0200, inch tube connectors variable speed drive compressor (heavy duty), mm tube connectors, for trucks and buses same as 109Z0250, inch tube connectors, for trucks and buses fixed speed drive compressor, mm tube connectors, for portable boxes Electronic Single Pack Code number for BD1.4F-AUTO, battery protection, 12 V, fixed speed (3,000 rpm) for BD1.4F-VSD/-HD, speed setting, battery protection, 12 - 24 V, variable speed (2,000 - 4,000 rpm)...

 Open the catalog to page 13
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-14

Hermetic Compressors for DC Voltage Part 2 Application examples BD compressors bring comfort at work and leisure The direct current compressors BD35F/50F/80F for 12/24 V DC power supply can be used in mobile refrigerators and freezers with refrigerant R134a. The BD250GH.2 and the BD350GH compressors in 12/24 or 48 V DC versions are R134a HBP compressors used for mobile spot cooling systems or telecommunication cooling. BD35K (R600a) and BD80/100CN (R290) compressors can be used with HFC-free refrigerants in stationary applications. All compressors are equipped with an electronic unit with built-in...

 Open the catalog to page 14
Hermetic compressors for DC Voltage Secop compresors produced fro Danfoss-15

Hermetic Compressors for DC Voltage Secop compressors produced for Danfoss mean: extraordinary performance at minimum power consumption, superbly silent running, reliable operation even when tilted up to 30 degrees, problem-free operation at 12/24/48 volts and more than 35 years’ of experience in mobile refrigeration. Transport stable, speed/capacity stable, multifunctional electronic, silent, high COP and compact design. FRCC.PK.047.A2.02 - Manufactured by Secop for Danfoss

 Open the catalog to page 15

Archived catalogs

  1. MCX15B

    6  Pages

  2. MBT 9110

    4  Pages

  3. MBT 5111

    4  Pages

  4. PLUS+1®

    2  Pages

  5. MBT 3560

    4  Pages

  6. MBT 3270

    8  Pages

  7. TP9000

    2  Pages

  8. RMT

    2  Pages

  9. FP735Si

    2  Pages

  10. FP975

    16  Pages

  11. DEVIlink

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.