Data Sheet ECtemp Next / Next Plus Electric Floor Heating Room Thermostats Application ECtemp Next ECtemp Next Plus All room thermostats are used for room temperature control in electric floor heating systems. By controlling room temperature in accordance with the temperature desired by the user, the room thermostats provide optimal energy savings while upholding optimal thermal comfort in the room. Functions • Modern design with white backlight. • AWAY function. • Child safety lock. • 3 selectable temperature control modes: 1. Room and floor temp. control (default). 2. Only floor temp. control. 3. Only room temp. control. (Please contact Danfoss how to set the only room temperature control) • Maximum floor temperature limitation • Optional room temperature display when power is OFF (default setting: no display). • Frost protection mode. Use this feature instead of turning the thermostat OFF completely to protect against damages due to low temperatures. The room temperature will be maintained around 5° C. • Temperature calibration. This function allows you to change the temperature setpoint of the room thermostat, to compensate for a possible temperature deviation between the room thermostat and, for example, the centre of the room. • Some features are only for ECtemp Next Plus as follows: • Advanced programmable timer. This function allows you to set a timer-controlled program for automatic comfort temperature and energysaving lower setback temperature when standard room comfort temperature is not required. Programmable 5/2-day feature with 4 time segments • Clock in 12-hour

Open the catalog to page 1
ECtemp Next / Next Plus - 2

Data Sheet ECtemp Next / Next Plus – Electric Floor Heating Room Thermostats Product Type Supply voltage Output voltage ECtemp Next ECtemp Next Plus Technical specifications ECtemp Next LCD display with push buttons ECtemp Next Plus LCD display with push buttons, programmable Operating room temperature Operating floor temperature Ambient temperature Fault indication Yes 1° C, symmetrical around the setpoint temperature Temperature calibration Power consumption Power supply Sensor, room Sensor, floor Shell material * It will be possible to set the maximum floor temperature up to 45° C....

Open the catalog to page 2
ECtemp Next / Next Plus - 3

Data Sheet ECtemp Next / Next Plus – Floor Heating Room Thermostats Wiring connections Room Thermostat, ECtemp Next / Next Plus

Open the catalog to page 3

All DANFOSS catalogs and technical brochures

  1. MCX15B

    6 Pages

  2. MBT 9110

    4 Pages

  3. MBT 5111

    4 Pages

  4. PLUS+1®

    2 Pages

  5. MBT 3560

    4 Pages

  6. MBT 3270

    8 Pages

  7. TP9000

    2 Pages

  8. RMT

    2 Pages

  9. FP735Si

    2 Pages

  10. FP975

    16 Pages

  11. DEVIlink

    2 Pages