OptymaTM Slim Pack Just mount, braze and plug R404A/R507, R134a, R407A, R407F - 50Hz
Open the catalog to page 1The cost effective outdoor solution Compact and light for easy handling and transportation System designed to perfectly fit into a compact and light housing. The OptymaTM Slim Pack weights up to 87 kg, which makes it the lightest solution in the market. Easy installation and cleaning With quick connections of suction & liquid lines & service ports outside OptymaTM Slim Pack is among the fastest & easiest to install. Easy-to-clean MCHE saves your time & efforts, ensuring longer lifetime & optimized efficiency. Thanks to the weatherproof housing and corrosion resistant micro-channel heat...
Open the catalog to page 4Features and cooling capacity R404A/R507 Main product features Micro channel heat exchanger Service ports outside Outdoor application • Fast and easy installation • Quick connections of suction & liquid lines • Shut off valves on receiver and service valves on service ports for easier & quick servicing • Easy & fast cleaning • Less refrigerant charge • Longer life time • Weatherproof housing IP54 • Robust and resistant to corrosion • Compact design Cooling capacity range (kW) 3.5 Freezing and storage of food Storage of fresh food and diary applicatios Conditions: +32˚C ambient temp.,...
Open the catalog to page 5Electrical code Test conditions Test condition Superheat 10K Subcooling 0K Cooling capacity range in (W) at evaporating temperature (°C) -40°C Sound Sound pressure power level level full dB(A) sphere 10m -10°C dB(A) Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz LLZ type compressor models are scroll compressors. Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value.
Open the catalog to page 6Power consumption referred at 32°C ambient temperature, SH 10K.
Open the catalog to page 7Test conditions Electrical code Test condition Superheat 10K Subcooling 0K Cooling capacity range in (W) at evaporating temperature (°C) -20°C Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz MLZ type compressor models are scroll compressors. Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value. Sound Sound pressure power level level full dB(A) sphere 10m +10°C dB(A)
Open the catalog to page 8Power consumption referred at 32°C ambient temperature, SH 10K.
Open the catalog to page 9Electrical code Test conditions Test condition Superheat 10K Subcooling 0K Coling capacity range in (W) at evaporating temperature (°C) -15°C Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz MLZ type compressor models are scroll compressors. Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value. Sound Sound pressure power level level full dB(A) sphere 10m dB(A)
Open the catalog to page 10Power consumption referred at 32°C ambient temperature, SH 10K.
Open the catalog to page 11Test condition Superheat 10K Subcooling 0K Electrical code Test conditions Coling capacity range in (W) at evaporating temperature (°C) Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz MLZ type compressor models are scroll compressors. Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value. *preliminary data. Sound Sound pressure power level level full dB(A) sphere 10m +10°C dB(A) 7350 6900 6350 5850 9150 8550 7850
Open the catalog to page 12Power consumption referred at 32°C ambient temperature, SH 10K.
Open the catalog to page 13Power consumption referred at 32°C ambient temperature, SH 10K
Open the catalog to page 15Spare parts & accessories MBP Electrical characteristics - 230V/1phase/50Hz LRA compressor (A) 230 V/ 1 phase Wiring diagram Max cont. power consumption (kW) Electrical characteristics - 400V/3phase/50Hz Unit Wiring diagram Max cont. power consumption (kW) Note LRA (Locked Rotor Amps) MCC (Maximum Continuous Current) Spare parts Unit Sight glass Dual Pressure switch Filter drier* *Filter drier DCL (appropriate model and size) can be used as a service replacememnt of DML
Open the catalog to page 16Catalogue Spare parts Unit Fan motor (W) (capacitor not included) Crankcase heater Suction valve Liquid valve 1/4" brazed 118U3413 Spare parts & accessories MBP *For B3 models produced before the 26th week of 2014 fan parts are the following: Fan capacitor - 118U3298 (6 μF) Accessories Unit Acoustic hood
Open the catalog to page 17Spare parts & accessories LBP Electrical characteristics - 230V/1phase/50Hz LRA compressor (A) 230 V/ 1 phase Max cont. power consumption (kW) Max cont. power consumption (kW) Wiring diagram Electrical characteristics - 400V/3phase/50Hz Wiring diagram Note LRA (Locked Rotor Amps) MCC (Maximum Continuous Current) Spare parts Unit Filter drier* Sight glass Condenser Dual Pressure switch *Filter drier DCL (appropriate model and size) can be used as a service replacememnt of DML
Open the catalog to page 18Spare parts & accessories LBP Spare parts Unit OP-LSHM015 OP-LSHM018 Fan motor (W) (capacitor not included) Suction valve Liquid valve Crankcase heater *For B3 models produced before the 26th week of 2014 fan parts are the following: Fan capacitor - 118U3298 (6 μF) Accessories Unit Acoustic hood OP-LSHM067 OP-LSHM084 OP-LSHM098 **Acoustic hood is included
Open the catalog to page 19AIR OUT 52 SERVICE VALVE HEIGHT 30 GRILLE HEIGHT FRONT VIEW CABLE ENTRY PORTS SUCTION PORT LIQUID PORT BACK VIEW
Open the catalog to page 2070 SERVICE VALVE HEIGHT 38 GRILLE HEIGHT 200 TYP. SUCTION PORT LIQUID PORT RH VIEW BACK VIEW FRONT VIEW CABLE ENTRY PORTS
Open the catalog to page 21Electrical wiring diagrams 21 wiring diagram/Schaltplan/plan de circuits WD 2 Legend/Legende/légende BK black/schwarz/noir BU blue/blau/bleu BN brown/braun/marron GY grey/grey/gris RD red/rot/rouge WH white/weiss/blanc F3 Fuse control circuit A1* Voltage relay (option) F4 Compressor thermal protector B1* Fan speed controller (option) M1 Compressor B2 High and Low pressure switch M2 Fan motor C1 Start capacitor compressor K1 Contactor C2 WD1: Start capacitor compressor K2 Start relay WD2: Run capacitor compressor R1 Bleeder resistor C3 Run capacitor fan S1* Room thermostat (option) E1...
Open the catalog to page 22All DANFOSS catalogs and technical brochures
-
MCX15B
6 Pages
-
Online Grocery
3 Pages
-
TP5000 Si Range
4 Pages
-
ECL Comfort 110
2 Pages
-
CANopen & SAE J1939
6 Pages
-
MBT 9110
4 Pages
-
MBT 5111
4 Pages
-
ADAP-KOOL® System Managers
6 Pages
-
PLUS+1®
2 Pages
-
MBC 8000 and MBC 8100
5 Pages
-
MBT 3560
4 Pages
-
MBT 3270
8 Pages
-
CANopen & SAE J1939
6 Pages
-
Danfoss Link & Heat Pump KIT
2 Pages
-
FEV-Z climate sensor
4 Pages
-
SpeedUp Heat Panels
2 Pages
-
ECtemp Next / Next Plus
3 Pages
-
Danfoss Heat Pumps
24 Pages
-
TP9000
2 Pages
-
Electronic Room Controls
1 Pages
-
Danfoss Brochure
12 Pages
-
Danfoss Link™
2 Pages
-
RMT
2 Pages
-
FP735Si
2 Pages
-
FP975
16 Pages
-
Outdoor Heating
1 Pages
-
Electric Floor Heating
1 Pages
-
ComLynx Datalogger
2 Pages
-
Avoid mold and energy waste
8 Pages
-
DEVIlink
2 Pages
-
Ground Voltage Control
2 Pages
-
Danfoss Solar Inverters
4 Pages