Catalog excerpts
Optyma PlusTM with scroll or reciprocating compressors R404A / R507, R134a, R407C
Open the catalog to page 1Optyma Plus™ R404A/R507 LBP/MBP The refrigerants R404A and R507 are used very widely in refrigeration. A major reason for their popularity is that they are highly flexible. For instance, applications in the standard refrigeration range are just as common as conventional freeze use with R404A or R507. For example, both refrigerants are used for dairy product refrigeration, whether for open storage of such foods or for storage of packaged goods. An example of a freeze application is the storage of frozen food and ice cream. Cold Room The refrigerant R134a is often underestimated as far as...
Open the catalog to page 2Optyma PlusTM the quiet plug and play solution In designing our Optyma PlusTM range we integrate your requirements in order to satisfy your needs and expectations of refrigeration solution. Optyma PlusTM combines our best engineering skills and design knowledge to create a fully factorybuilt condensing unit ready for quick installation and quiet operation. Optyma PlusTM is a unique integral Danfoss condensing unit built around Danfoss components. Optyma PlusTM can be located anywhere. Acoustic insulation and fan speed reduction during low capacity operation periods makes the operation of...
Open the catalog to page 3Cooling capacity range in (W) at evaporating temperature (°C) Subcooling within the limits of the condensing unit Power consumption referred at 32°C ambient temperature Test condition EN13215 SH 10K Ambient temperature 32°C Power consumption (W) at -25°C evap. temp. Test conditions Electrical code E: Compressor 400 V/3 phase/50 Hz, fan 230 V/1 phase/50 Hz G: Compressor 230 V/1 phase/50 Hz, fan 230 V/1 phase/50 Hz
Open the catalog to page 4pressure Weight level Gross/Net Sound measurement done in accordance with ISO 3743-1 and ISO 3744.
Open the catalog to page 5Test conditions Test condition EN13215 SH 10K Ambient temperature 32°C Subcooling within the limits of the condensing unit Power consumption referred at 32°C ambient temperature Cooling capacity range in (W) at evaporating temperature (°C) -20°C Electrical code G: Compressor 230 V/1 phase/50 Hz, fan 230 V/1 phase/50 Hz E: Compressor 400 V/3 phase/50 Hz, fan 230 V/1 phase/50 Hz Power consumption (W) at evap. temp. -10°C 570
Open the catalog to page 6Optyma Plus™ R404A/R507 MBP Condenserfan Airflow Int. volume Fan blade Ø (m3/h) (L) (mm) Condenser coil Type Dimensions (mm) Height Width H W Sound Connection Sound Weight pressure (Inch) power level Suction Liquid Gross/Net level dB(A) line line (kg) 10 m dB(A) Sound measurement done in accordance with ISO 3743-1 and ISO 3744.
Open the catalog to page 7Test conditions Cooling capacity range in (W) at evaporating temperature (°C) -15°C Test conditions Electrical code EN13215 SH10K Ambient temperature 32°C E: Compressor 400 V/3 phase/50 Hz, fan 230 V/1 phase/50 Hz Compressor 230 V/1 phase/50 Hz, fan 230 V/1 phase/50 Hz G: Subcooling within the limits of the condensing unit Power consumption referred at 32°C ambient temperature Power consumption (W) at evap. temp. -10°C 750
Open the catalog to page 8Sound measurement done in accordance with ISO 3743-1 and ISO 3744.
Open the catalog to page 9Test conditions Cooling capacity range in (W) at evaporating temperature (°C) Test condition EN13215 SH 10K Ambient temperature 32°C Electrical code E: Compressor 400 V/3 phase/50 Hz, fan 230 V/1 phase/50 Hz G: Compressor 230 V/1 phase/50 Hz, fan 230 V/1 phase/50 Hz Subcooling within the limits of the condensing unit Power consumption referred at 32°C ambient temperature Power consumption (W) at evap. temp. -10°C
Open the catalog to page 10Optyma Plus™ R407C MBP Condenser coil Receiver Airflow Int. volume Fan blade Ø volume (L) (m3/h) (L) (mm) Connection (Inch) Suction line Liquid line Sound power level dB(A) Sound Weight pressure level Gross/Net 10 m (kg) dB(A) Sound measurement done in accordance with ISO 3743-1 and ISO 3744.
Open the catalog to page 11Electrical characteristics – 230 V, 1 phase, 50 Hz Unit Wiring diagram Max. continuous power consumption (kW) Main switch Code number Electrical characteristics – 400 V, 3 phase, 50 Hz Unit Wiring diagram Max. continuous power consumption (kW) Main switch Code number Moeller spare parts or individual electrical components are not supplied by Danfoss Spare parts Unit Filter drier Sight glass Pressure switch Liquid valve Spare parts Receiver volume (L) Unit Platform Fan Motor (capacitor included) OP-LPHC271 NT 14.0 118U0006 13.6 118U0026 Note: LRA (Locked Rotor Amps) A = Receiver without...
Open the catalog to page 12Electrical characteristics – 230 V, 1 phase, 50 Hz Unit Wiring diagram Max. continuous power consumption (kW) Main switch Code number Electrical characteristics – 400 V, 3 phase, 50 Hz Unit Wiring diagram Max. continuous power consumption (kW) Main switch Code number Moeller spare parts or individual electrical components are not supplied by Danfoss
Open the catalog to page 14Filter drier Sight glass Pressure switch Suction valve Liquid valve Spare parts Spare parts Receiver volume (L) Fan Motor (capacitor included) Handling handle A = Receiver without valve B = Receiver with valve on top *fan motor should be replaced by the old one 118U3478 (75 W) for the unit with serial number up to xxxxxxCG4812 produced before December 2012.
Open the catalog to page 15Electrical characteristics – 230 V, 1 phase, 50 Hz Unit Wiring diagram Max. continuous power consumption (kW) Main switch Code number Electrical characteristics – 400 V, 3 phase , 50 Hz Unit Wiring diagram Max. continuous power consumption (kW) Main switch Code number Moeller spare parts or individual electrical components are not supplied by Danfoss
Open the catalog to page 16Spare parts Unit Filter drier Sight glass Pressure switch Suction valve Liquid valve Spare parts Receiver volume (L) Fan Motor (capacitor included) Handling handle Note: LRA (Locked Rotor Amps) MCC (Maximum Continuous Current) A = Receiver without valve B = Receiver with valve on top *fan motor should be replaced by the old one 118U3478 (75 W) for the unit with serial number up to xxxxxxCG4812 produced before December 2012.
Open the catalog to page 17Electrical characteristics – 230 V, 1 phase, 50 Hz Unit Wiring diagram Max. continuous power consumption (kW) Main switch Code number Electrical characteristics – 400 V, 3 phase, 50 Hz Unit Wiring diagram Max. continuous power consumption (kW) Main switch Code number Moeller spare parts or individual electrical components are not supplied by Danfoss
Open the catalog to page 18All DANFOSS catalogs and technical brochures
-
MCX15B
6 Pages
-
Online Grocery
3 Pages
-
TP5000 Si Range
4 Pages
-
ECL Comfort 110
2 Pages
-
CANopen & SAE J1939
6 Pages
-
MBT 9110
4 Pages
-
MBT 5111
4 Pages
-
ADAP-KOOL® System Managers
6 Pages
-
PLUS+1®
2 Pages
-
MBC 8000 and MBC 8100
5 Pages
-
MBT 3560
4 Pages
-
MBT 3270
8 Pages
-
CANopen & SAE J1939
6 Pages
-
Danfoss Link & Heat Pump KIT
2 Pages
-
FEV-Z climate sensor
4 Pages
-
SpeedUp Heat Panels
2 Pages
-
ECtemp Next / Next Plus
3 Pages
-
Danfoss Heat Pumps
24 Pages
-
TP9000
2 Pages
-
Electronic Room Controls
1 Pages
-
Danfoss Brochure
12 Pages
-
Danfoss Link™
2 Pages
-
RMT
2 Pages
-
FP735Si
2 Pages
-
FP975
16 Pages
-
Outdoor Heating
1 Pages
-
Electric Floor Heating
1 Pages
-
ComLynx Datalogger
2 Pages
-
Avoid mold and energy waste
8 Pages
-
DEVIlink
2 Pages
-
Ground Voltage Control
2 Pages
-
Danfoss Solar Inverters
4 Pages