1. Catalogs
  2. DANFOSS
  3. Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI

Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI

Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI
1 / 28 PagesView full catalog

Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI

Product catalog summary
Overview: The document provides comprehensive information on the Optyma Plus™ New Generation refrigeration solution, highlighting its quiet operation, energy efficiency, and multirefrigerant capability. It is suitable for both low and medium temperature applications and supports refrigerants like R404A/R507, R134a, R407A, and R407F.
Main Features: Key features include a smart compressor design for quiet operation, energy-efficient components, compliance with the ErP directive, and a compact design for easy installation. The unit is designed for effortless installation with pre-set parameters and is weather-resistant.
Cooling Capacity: The cooling capacity ranges from 0.6 kW to 16.5 kW, depending on the refrigerant and application, with configurations available for both MBP and LBP.
Electrical Characteristics: The units are available in 230V/1phase/50Hz and 400V/3phase/50Hz configurations.
Applications: Suitable for fresh food storage, dairy applications, freezing, and food storage.
Additional Information: Spare parts and accessories are available, with detailed electrical wiring diagrams and dimensions provided for installation guidance.
Specifications: The document lists multiple MLZ type scroll compressors with specific cooling capacities and electrical codes for different configurations.
Performance Data: Includes detailed tables of cooling capacities, sound levels, and power consumption at a standard ambient temperature of 32°C.
Component Details: Information on condenser specifications, spare parts, and electrical characteristics is provided, including LRA and MCC details.
Recommendations: Ensure compatibility of electrical configurations before installation and perform regular maintenance as per specifications.
Spare Parts Specifications: The catalogue lists spare parts with specific part numbers and compatibility notes.
Designation System: Explains the coding system for identifying unit specifications based on application, refrigerant type, and other factors.
Selection Guide: Provides guidance on selecting the appropriate unit based on application needs, including cooling capacities and cold room volumes.
Dimensions and Wiring Diagrams: Detailed dimensions and comprehensive wiring diagrams are provided for installation and troubleshooting.
Company Information: Danfoss is recognized as a leader in compressor and condensing unit manufacturing, emphasizing energy efficiency and sustainability.
See more

Catalog excerpts

Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-1

Optyma PlusTM New Generation Plug and play solution R404A/R507, R134a, R407A, R407F - 50Hz

 Open the catalog to page 1
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-4

The new generation of quiet Plug & Play solution Silent and outstanding performance The Optyma Plus™ New Generation can be located even in residential areas. Smart compressor design, acoustic insulation and fan speed reduction during low capacity operation periods make the Optyma Plus™ the quitest solution today to respect your environment. Increased efficiency and sustainable solutions With the Optyma Plus™ New Generation substantial energy savings can be achieved thanks to the energy efficient components inside such as: optimized compressors, micro channel heat exchanger, high efficiency fan...

 Open the catalog to page 4
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-5

Features and cooling capacity Main product features Micro channel heat exchanger Electronic controller Parameter monitoring and control On site stack mounting Fully weather resistant Compact design Cooling capacity range (kW) Freezing and storage of food Storage of fresh food and diary applications Conditions: +32˚C ambient temp., superheat 10K, subcooling 0K MBP: -10 ˚C evaporating temp LBP: -25 ˚C evaporating temp * preliminary data, ongoing qualifications Optyma PlusTM units can work in the following evaporating temperature range: LBP R404A -40°C to -10°C MBP R404A -20°C to +10°C MBP R407A/F...

 Open the catalog to page 5
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-6

Test conditions Amb. Electrical Compressor temp. code °C Cooling capacity range in (W) at evaporating temperature (°C) -40°C Sound Sound pressure power level full level -10°C dB(A) sphere 10m dB(A) Test condition Superheat 10K Subcooling 0K Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz Units can operate down to -45 evaporating temperature. Refer to dedicated Software or contact Danfoss for more details Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of...

 Open the catalog to page 6
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-7

Power consumption referred at 32°C ambient temp.

 Open the catalog to page 7
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-8

Test conditions Amb. Electrical Compressor temp code °C -20°C Test condition Superheat 10K Subcooling 0K Cooling capacity range in (W) at evaporating temperature (°C) -15°C Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz MLZ type compressor models are scroll compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value. *Certified performance - Asercom Sound Sound pressure power level full level sphere +10°C dB(A) 10m dB(A) 60

 Open the catalog to page 8
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-9

Power consumption referred at 32°C ambient temp

 Open the catalog to page 9
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-10

Test conditions Amb. Electrical Compressor temp. code °C -15°C Cooling capacity range in (W) at evaporating temperature (°C) -10°C Sound Sound pressure power level full level sphere +15°C dB(A) 10m dB(A) Test condition Superheat 10K Subcooling 0K Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value MLZ type compressor models are scroll compressors

 Open the catalog to page 10
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-11

Power consumption referred at 32°C ambienttemp

 Open the catalog to page 11
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-12

Test conditions Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz MLZ type compressor models are scroll compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value * preliminary data Test condition Superheat 10K Subcooling 0K Cooling capacity range in (W) at evaporating temperature (°C) Sound Sound pressure power level full level sphere +10°C dB(A) 10m dB(A) 7350 Amb. Electrical Compressor temp. code °C

 Open the catalog to page 12
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-13

Power consumption referred at 32°C ambienttemp

 Open the catalog to page 13
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-14

Test conditions Cooling capacity range in (W) at evaporating temperature (°C) Sound Sound pressure power level full level sphere +10°C dB(A) 10m dB(A) 7750 Amb. Electrical Compressor temp. code °C -20°C 43 Test condition Superheat 10K Subcooling 0K Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz MLZ type compressor models are scroll compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value *preliminary data

 Open the catalog to page 14
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-15

Power consumption referred at 32°C ambienttemp

 Open the catalog to page 15
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-16

Spare parts & accessories LBP Electrical characteristics - 230V/1phase/50Hz Unit Wiring diagram MCC compressor (A) Max cont. power 230 V/ 1 phase consumption (kW) LRA (Locked Rotor Amps) MCC (Maximum Continuous Current) Electrical characteristics - 400V/3phase/50Hz Unit Wiring diagram LRA compressor (A) MCC compressor (A) Max cont. power 400 V/ 3phase 400 V/ 3phase consumption (kW) LRA (Locked Rotor Amps) MCC (Maximum Continuous Current) Spare parts Unit Filter drier Sight glass Suction valve Liquid valve High Pressure switch

 Open the catalog to page 16
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-17

Spare parts Receiver (L) Fan motor (W) (capacitor not included) Optyma PlusTM Controller Spare parts & accessories LBP OP-LPHM271 *Fan motor should be replaced with the old one 118U3478 (75 W) for the unit with serial number up to xxxxxxCG5212 produced before December 2012 **For H3 and H4 models produced before the 26th week of 2014 fan parts are the following: Fan capacitor - 118U3298 (6 μF) Fan motor - 118U3479 (130 W) Fan blade - 118U3833 (f24”) Spare parts Unit OP-LPHM018 OP-LPHM026 Temperature sensor (suction & ambient) Crankcase heater Discharge pressure transmitter Suction pressure transmitter...

 Open the catalog to page 17
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI-18

Spare parts & accessories MBP Electrical characteristics - 230V/1phase/50Hz Unit Wiring diagram LRA (Locked Rotor Amps) LRA compressor (A) MCC compressor (A) 230 V/ 1 phase 230 V/ 1 phase Max cont. power consumption (kW) MCC (Maximum Continuous Current) Electrical characteristics - 400V/3phase/50Hz Unit Wiring diagram LRA (Locked Rotor Amps) Max cont. power consumption (kW) MCC (Maximum Continuous Current) Spare parts Unit Filter drier Sight glass Suction valve Liquid valve High Pressure switch

 Open the catalog to page 18

Archived catalogs

  1. MCX15B

    6  Pages

  2. MBT 9110

    4  Pages

  3. MBT 5111

    4  Pages

  4. PLUS+1®

    2  Pages

  5. MBT 3560

    4  Pages

  6. MBT 3270

    8  Pages

  7. TP9000

    2  Pages

  8. RMT

    2  Pages

  9. FP735Si

    2  Pages

  10. FP975

    16  Pages

  11. DEVIlink

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.