Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI
28Pages

{{requestButtons}}

Catalog excerpts

Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 1

Optyma PlusTM New Generation Plug and play solution R404A/R507, R134a, R407A, R407F - 50Hz

Open the catalog to page 1
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 4

The new generation of quiet Plug & Play solution Silent and outstanding performance The Optyma Plus™ New Generation can be located even in residential areas. Smart compressor design, acoustic insulation and fan speed reduction during low capacity operation periods make the Optyma Plus™ the quitest solution today to respect your environment. Increased efficiency and sustainable solutions With the Optyma Plus™ New Generation substantial energy savings can be achieved thanks to the energy efficient components inside such as: optimized compressors, micro channel heat exchanger, high efficiency...

Open the catalog to page 4
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 5

Features and cooling capacity Main product features Micro channel heat exchanger Electronic controller Parameter monitoring and control On site stack mounting Fully weather resistant Compact design Cooling capacity range (kW) Freezing and storage of food Storage of fresh food and diary applications Conditions: +32˚C ambient temp., superheat 10K, subcooling 0K MBP: -10 ˚C evaporating temp LBP: -25 ˚C evaporating temp * preliminary data, ongoing qualifications Optyma PlusTM units can work in the following evaporating temperature range: LBP R404A -40°C to -10°C MBP R404A -20°C to +10°C MBP...

Open the catalog to page 5
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 6

Test conditions Amb. Electrical Compressor temp. code °C Cooling capacity range in (W) at evaporating temperature (°C) -40°C Sound Sound pressure power level full level -10°C dB(A) sphere 10m dB(A) Test condition Superheat 10K Subcooling 0K Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz Units can operate down to -45 evaporating temperature. Refer to dedicated Software or contact Danfoss for more details Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1%...

Open the catalog to page 6
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 7

Power consumption referred at 32°C ambient temp.

Open the catalog to page 7
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 8

Test conditions Amb. Electrical Compressor temp code °C -20°C Test condition Superheat 10K Subcooling 0K Cooling capacity range in (W) at evaporating temperature (°C) -15°C Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz MLZ type compressor models are scroll compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value. *Certified performance - Asercom Sound Sound pressure power level full level sphere +10°C dB(A) 10m dB(A) 60

Open the catalog to page 8
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 9

Power consumption referred at 32°C ambient temp

Open the catalog to page 9
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 10

Test conditions Amb. Electrical Compressor temp. code °C -15°C Cooling capacity range in (W) at evaporating temperature (°C) -10°C Sound Sound pressure power level full level sphere +15°C dB(A) 10m dB(A) Test condition Superheat 10K Subcooling 0K Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value MLZ type compressor models are scroll compressors

Open the catalog to page 10
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 11

Power consumption referred at 32°C ambienttemp

Open the catalog to page 11
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 12

Test conditions Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz MLZ type compressor models are scroll compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value * preliminary data Test condition Superheat 10K Subcooling 0K Cooling capacity range in (W) at evaporating temperature (°C) Sound Sound pressure power level full level sphere +10°C dB(A) 10m dB(A) 7350 Amb. Electrical Compressor temp. code °C

Open the catalog to page 12
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 13

Power consumption referred at 32°C ambienttemp

Open the catalog to page 13
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 14

Test conditions Cooling capacity range in (W) at evaporating temperature (°C) Sound Sound pressure power level full level sphere +10°C dB(A) 10m dB(A) 7750 Amb. Electrical Compressor temp. code °C -20°C 43 Test condition Superheat 10K Subcooling 0K Electrical code E - Compressor 400V/3phase/50Hz, fan 230V/1phase/50 Hz G - Compressor 230V/1phase/50Hz, fan 230V/1phase/50 Hz MLZ type compressor models are scroll compressors Cooling capacity is given for units with 3-phase compressor. Capacity of single-phase versions is within +/- 1% of this value *preliminary data

Open the catalog to page 14
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 15

Power consumption referred at 32°C ambienttemp

Open the catalog to page 15
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 16

Spare parts & accessories LBP Electrical characteristics - 230V/1phase/50Hz Unit Wiring diagram MCC compressor (A) Max cont. power 230 V/ 1 phase consumption (kW) LRA (Locked Rotor Amps) MCC (Maximum Continuous Current) Electrical characteristics - 400V/3phase/50Hz Unit Wiring diagram LRA compressor (A) MCC compressor (A) Max cont. power 400 V/ 3phase 400 V/ 3phase consumption (kW) LRA (Locked Rotor Amps) MCC (Maximum Continuous Current) Spare parts Unit Filter drier Sight glass Suction valve Liquid valve High Pressure switch

Open the catalog to page 16
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 17

Spare parts Receiver (L) Fan motor (W) (capacitor not included) Optyma PlusTM Controller Spare parts & accessories LBP OP-LPHM271 *Fan motor should be replaced with the old one 118U3478 (75 W) for the unit with serial number up to xxxxxxCG5212 produced before December 2012 **For H3 and H4 models produced before the 26th week of 2014 fan parts are the following: Fan capacitor - 118U3298 (6 μF) Fan motor - 118U3479 (130 W) Fan blade - 118U3833 (f24”) Spare parts Unit OP-LPHM018 OP-LPHM026 Temperature sensor (suction & ambient) Crankcase heater Discharge pressure transmitter Suction pressure...

Open the catalog to page 17
Catalogue - Optyma Plus New Generation - GB - 50 Hz - SI - 18

Spare parts & accessories MBP Electrical characteristics - 230V/1phase/50Hz Unit Wiring diagram LRA (Locked Rotor Amps) LRA compressor (A) MCC compressor (A) 230 V/ 1 phase 230 V/ 1 phase Max cont. power consumption (kW) MCC (Maximum Continuous Current) Electrical characteristics - 400V/3phase/50Hz Unit Wiring diagram LRA (Locked Rotor Amps) Max cont. power consumption (kW) MCC (Maximum Continuous Current) Spare parts Unit Filter drier Sight glass Suction valve Liquid valve High Pressure switch

Open the catalog to page 18

All DANFOSS catalogs and technical brochures

  1. MCX15B

    6 Pages

  2. MBT 9110

    4 Pages

  3. MBT 5111

    4 Pages

  4. PLUS+1®

    2 Pages

  5. MBT 3560

    4 Pages

  6. MBT 3270

    8 Pages

  7. TP9000

    2 Pages

  8. RMT

    2 Pages

  9. FP735Si

    2 Pages

  10. FP975

    16 Pages

  11. DEVIlink

    2 Pages