Introduction
Cooling IT equipment in data centers is increasingly challenging due to power management, energy consumption, and heat loads. Danfoss inverter scrolls offer advanced efficiency and accurate cooling to address these challenges.

Key Challenges
  • Power management and energy consumption are major concerns.
  • Cooling can account for up to 50% of a data center's energy cost.
  • Accurate humidity and static electricity control are essential.
  • Minimum start-up current is crucial for sensitive power grids, reducing downtime and increasing system lifetime.

Danfoss VZH Compressor Features
  • Capacity range: 13-26TR (47-94kW) in a single unit, up to 52TR in tandem.
  • Extended modulation capacity from 25 to 100 rps.
  • Operates with R410A refrigerant.
  • Optimized for low and high pressure ratios.

Energy Savings
  • The VZH inverter scroll cycles from 25 to 100 RPS, reducing energy waste.
  • Consumes 90% less energy in part-load operation compared to fixed-speed compressors.
  • Patented manifold technology increases capacity range up to 183 kW (52TR) at full speed.

Accurate Temperature and Humidity Control
  • Temperature control within +/- 0.3°C ensures data availability and protects components.
  • Maintains optimal humidity levels to prevent Electro-Static Discharge (ESD).

Reduced Applied Costs
  • Prequalified compressor and drive package speeds up time to market and enhances reliability.
  • Drive replaces soft starter device, reducing inrush current by about 70%.
  • Reduces investment in Uninterruptible Power Supply (UPS).

Enhanced Reliability
  • Modulates cooling capacity according to load, reducing frequent on-off cycles.
  • Prequalified drive reduces vibration issues, ensuring safe operation and prolonging unit lifetime.

Conclusion
Danfoss inverter scroll solutions provide significant energy savings, accurate control, and enhanced reliability, making them an ideal choice for data center cooling.
See more

Catalog excerpts

Brochure Datacenter cooling with VZH inverter scrolls - GB-1

Danfoss Inverter Scrolls VZH Advanced efficiency, accurate cooling. Design an HVAC system like no other Cooling IT equipment in data centers is an increasing challenge for operators and design engineers. Power management is the major concern, followed by energy consumption and heat loads. Meeting these challenges is essential for ensuring data safety and availability. Discover how Danfoss inverter scrolls can help you. energy savings significantly reduces energy bill.

 Open the catalog to page 1
Brochure Datacenter cooling with VZH inverter scrolls - GB-2

Danfoss inverter scroll solutions: the easiest way for you to build the best data center ever • Capacity range: 13-26TR (47-94kW) in a single unit; up to 52TR in tandem • The most extended modulation capacity from 25 to 100 rps • Operates with R410A • Two ranges optimized for low and high pressure ratios Power management is the major challenge, followed by energy consumption and heat loads in data centers. Other important factors are: • Cost optimization: cooling can be up to 50% of the overall energy cost in a data center • Accurate humidity and static electricity control • Minimum start-up...

 Open the catalog to page 2

Archived catalogs

  1. MCX15B

    6  Pages

  2. MBT 9110

    4  Pages

  3. MBT 5111

    4  Pages

  4. PLUS+1®

    2  Pages

  5. MBT 3560

    4  Pages

  6. MBT 3270

    8  Pages

  7. TP9000

    2  Pages

  8. RMT

    2  Pages

  9. FP735Si

    2  Pages

  10. FP975

    16  Pages

  11. DEVIlink

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.