video corpo

H08-iglu-en
3Pages

{{requestButtons}}

Catalog excerpts

H08-iglu-en - 1

H 8 cm Ventilated under-floor cavities for civil and industrial buildings that are being built new or reconstructed. - Urban infrastructure structures: squares, sidewalks, sports facility. • Creation of an intermediate slab or roofing for cavities used for ventilation and the passage of systems. • Rooms used for humidity and temperature control: drying cells, cold rooms, greenhouses, storage rooms and cellars. • Underground pipes for the passage of utilities. Inspectionable cavities and pits. • By filling it in simply with expanded clay, it can be used to create roof-top gardens. • Underground ducts for the dispersion of water and for drainage. • Overhead sidewalks for passenger loading and unloading or the creation of floating floors. • Levelling height. DALIFORM GROUP DALIFORM GROUP Passage of nr. 3 tubes Ø 56 mm for tunnel 52 cm The images are only for examples. Recyclable material is allowed a size tolerance of ± 1,5%. Quantity (of concrete to the crown) The volume may vary depending on the pouring condition and the tolerance of the material.

Open the catalog to page 1
H08-iglu-en - 2

PRESSURES AT THE BOTTOM OF THE STRUCTURE Thickness of the lean concrete cm Pressure at pillar base [2] MPa [1] Characteristic values [2] Project values (Ultimate SLU Limit State - Coefficients A1) The table expresses, starting from the various examples of overload and of thickness (to be given to the slab), the pressures that would be applied to the feet of the structure, in relation to the (eventual) thicknesses of the lean concrete. The overload hypotheses are indicated in table as an example; the actual load capacity is far superior. To know the exact values or sizing as shown in the...

Open the catalog to page 2
H08-iglu-en - 3

TECHNICAL PACKING AND TRUCKING m 1 pallet: 4 piles of 150 pieces Each pallet is identified with: - BBA; - Declaration of Performance Conformity; - Hygienic certificate; - Acoustic check for verification of DIN standards; Avis Technique; - Rupture load tests; - Productive process monitoring tests; - Certificate of Environmental Compatibility. 600 A coloured band containing: the brand, a type image of the product, the Company name, teh website and any warnings. A lebel with the following informations: product’s name and code, quantity, Certificate of the Environmental Compatibility, date of...

Open the catalog to page 3

All DALIFORM GROUP srl catalogs and technical brochures

  1. H09-iglu-en

    3 Pages

  2. H06-iglu-en

    3 Pages

  3. H05-iglu-en

    3 Pages

  4. H04-iglu-en

    3 Pages

  5. GREENPARK_EN

    8 Pages

  6. V-Green_EN

    4 Pages

  7. COFFRARGILE

    12 Pages

  8. IGLU'®

    24 Pages

  9. ATLANTIS

    16 Pages

  10. ISO IGLU'

    8 Pages

  11. ATLANTIS TANK

    20 Pages

  12. V-GREEN®

    4 Pages

  13. EASY RIDE

    4 Pages

  14. EASY PARK®

    8 Pages

  15. U-BAHN® BETON

    10 Pages

  16. FIT SLAB

    10 Pages

  17. U-BOOT® BETON

    21 Pages

Archived catalogs

  1. EOLO

    9 Pages