Impact Protection Ratings (IK Codes)

The document defines IK ratings from IK00 (no protection) to IK09 (10 Joules impact resistance), specifying the mechanical robustness of lighting equipment to ensure durability and safety in various environments.

Light Sources and Battery Types

Light sources include fluorescent, LED, incandescent, halogen, and neon lamps. Battery types are Nickel-Metal Hydride (Ni-MH) and Nickel-Cadmium (Ni-Cd), with lumen output linked to battery autonomy to indicate brightness duration during emergencies.

Operation Modes and Features

  • Non-maintained (NM): Emergency lighting activates only during power failure.
  • Maintained (M): Emergency lighting remains on continuously.
  • Combined (C): Supports both maintained and non-maintained modes.
  • Eco-maintained (ECO+): Energy-efficient LED-based maintained lighting.
  • Remote controllable: Enables remote switching during outages.
  • Emergency luminaire disabling: Option to disable emergency lighting during power failure.

Testing and Monitoring Functions

  • Autotest (A-TEST): Automatic self-testing of battery, light source, and unit status with indicators.
  • DaisaTest (TCA): Centralized computer monitoring for maintenance optimization.

Photometric Characteristics

  • Symmetrical optics optimized for anti-panic lighting at ceiling heights 2.2–5 m.
  • Asymmetrical optics optimized for evacuation routes at similar mounting heights.

Product Range and Compatibility

Multiple product models (e.g., Lens R, Argos, Hydra, Galia, Orto, Zenit, Lisu, Alzir, Aqua, Lyra, Leda, Clavo, Sherpa) are detailed with compatibility matrices indicating applicable features and certifications.

Installation and Environmental Suitability

  • Suitable for interior and exterior use, with or without direct sunlight exposure.
  • Installation types include recessed, semi-recessed, surface-mounted, and flush mounting in technical or solid ceilings and walls.

Multilingual Terminology

Key terms related to light sources, battery types, operation modes, installation, and features are provided in Spanish, English, German, French, Italian, and Portuguese to support international application.

Critical Parameters and Recommendations

  • Select impact resistance based on environmental risks.
  • Match battery autonomy and lumen output to emergency duration needs.
  • Choose operation mode according to application requirements.
  • Use testing modes (Autotest, DaisaTest) to ensure reliability and reduce maintenance costs.
  • Select photometric optics based on mounting height and lighting purpose.
  • Verify installation methods and environmental suitability for compliance and durability.

Product Installation Options

Various mounting options are described, including flush mounting in suspended or solid ceilings, surface mounting on walls, and recessed or semi-recessed mounting, emphasizing installation versatility.

Certifications and Standards

  • Compliance with EN 60598-1 and EN 60598-2-22 (IEC standards for luminaires and emergency lighting).
  • French standards NF C 71-801, NF C 71-820 (SATI), UTE C 71-806.
  • EN 1838 for emergency lighting requirements.
  • Safety signage standards EN ISO 7010 and DIN 4844.
  • European Directives: Low Voltage (2006/95/CE), EMC (2004/108/CE), RoHS (2002/95/CE), WEEE (2002/96/CE).
  • ATEX certification for explosion-proof lighting (Antideflagrante series).
  • RETILAP certification for Spanish emergency lighting compliance.

Product Features and Technical Parameters

  • LED technology with ECO+ efficiency.
  • Battery types: NiMH and NiCd.
  • Ingress Protection (IP) ratings from IP20 to IP66 depending on model.
  • Impact resistance mostly IK04 or IK08.
  • Emergency operation durations of 1, 2, or 3 hours.
  • Luminous flux ranges approximately 70 to 1000 lumens.
  • Various lens types with specific dimensions and photometric distributions.

Photometric Data and Lens Options

Detailed photometric diagrams show candela distribution curves for multiple lens types and models, supporting selection based on mounting height and desired light spread. Lens diameters typically range from 40 mm to 150 mm.

Product Families and Models

  • Block series: Block M, Block20, Block22.
  • Lens series: Multiple variants including R, MET, SEN, SM, CD, CDSM, AD, EST, S, ESP, ES, ESM.
  • Izar, Hydra, Argos series: Each with distinct technical specs and photometric characteristics.

Technical Parameters and Performance

  • Photometric data includes angular luminous intensity distributions (cd/Klm) from -90º to +90º.
  • Battery autonomy options typically 1 to 3 hours.
  • IP ratings from IP22 to IP66, indicating environmental suitability.
  • Impact resistance ratings mostly IK04, some IK07 or IK08.
  • Dimensions provided for installation planning.

Compliance and Environmental Considerations

  • RoHS and WEEE directives ensure restriction of hazardous substances and proper waste management.
  • Electromagnetic compatibility and low voltage safety ensured by relevant European directives.
  • Safety signage compliance with EN ISO 7010 and DIN 4844 standards.

Recommendations and Usage

  • Choose product series based on environmental conditions, luminous flux, and autonomy requirements.
  • Use explosion-proof models (Antideflagrante) for hazardous areas requiring ATEX certification.
  • Review photometric data to ensure adequate light distribution.
  • Ensure compliance with local and international standards for safety and regulatory acceptance.

Software Tools for Project Design

Daisalux offers "Daisa 6" software for precise emergency lighting project design, ensuring compliance with EN 1838 and optimizing costs. A free project design service is available via the manufacturer.

Additional Information and Contact

Further technical details, certifications, and product information are accessible at www.daisalux.com. Customer support is available via [email protected], and project assistance can be requested at [email protected].

Summary

This document is a comprehensive technical reference for Daisalux emergency lighting products, covering specifications, certifications, photometric data, installation options, and design tools. It emphasizes compliance with international standards, product reliability, and optimized project planning to meet safety and regulatory requirements.

See more

Catalog excerpts

Universal Catalog-4

Fuente de luz: Lámpara fluorescente. Light source: Fluorescent lamp. Lichtquelle: Leuchtstofflampe. Source de lumière: Lampe fluorescente. Sorgente luminosa: Lampada Fonte de luz: Lâmpada fluorescente. fluorescente. Non-maintained Operation. Funcionamiento Permanente. Maintained Operation. Fonctionnement permanent. Funzionamento Permanente. Funcionamento Permanente. Funcionamiento Combinado. Combined Operation. Fonctionnement combiné. Funzionamento Combinato. Funcionamento Combinado. Funcionamiento Ecopermanente. Fuente de luz: LED. Eco-maintained Operation. Light source: LED. Fonctionnement...

 Open the catalog to page 4
Universal Catalog-7

020 Block 024 Lens R 040 Lens C 048 Lens AD 052 Lens EST 056 Lens S 060 Lens ESP 064 Lens ES 072 Izar 076 Hydra 080 Hydra-G 084 Hydra-RE 088 Argos 092 Argos-D 096 Argos-M 100 Nova 104 Myra 108 Norma 112 Iris 116 Sol 120 Luna 124 Galia 128 Galia-B 132 Galia-AD 136 Galia-S 140 Orto-S 144 Orto 148 Orto-RE 152 Carril 156 Antideflagrante 160 Estanca 164 Zenit 168 Zenit PL 172 Zenit Estanco 176 Vir 320x195 180 Vir 210x210 184 Vir 160x160 188 Lisu 192 Lisu-B 196 Lisu-AD 200 Lisu-S 204 Alzir 208 Alzir-Inox 212 Lecu 216 Aqua 220 Lyra 224 Leda 228 Clavo 232 Sherpa ES Apto para interior. Convient pour une...

 Open the catalog to page 7
Universal Catalog-8

Apta para colocación en superficie: Techo técnico o macizo. Suitable for surfacemounting in technical or solid ceilings. Apta para empotrar/ semiempotrar en techo técnico o macizo. Geeignet zur Anbringung an der Oberfläche: abgehängte oder massive Decke. Peut être installé sur les surfaces suivantes: Faux plafond ou plafond béton. Adatta per il montaggio a soffitto in superficie. Suitable for recessed/ Geeignet zum Einbau/ semi-recessed in technical Halbeinbau in einer or solid ceilings. abgehängten oder massiven Decke Peut être encastré/ semi-encastré dans un faux plafond ou plafond béton. Adatta...

 Open the catalog to page 8
Universal Catalog-49

46 Lens C Lens (CDSM)

 Open the catalog to page 49
Universal Catalog-50

Lens (CDSM) MHBLED N20/P20 R1191E3996 50 Lens (CDSM) MHBLED N30/P30 R1195E3996 50 Lens (CDSM) MHBLED N40/P40 R1193E3996 -80º Lens (CDSM) MHBLED N70/P70 R1197E3996 100

 Open the catalog to page 50
Universal Catalog-55

+Info *XNAA www.daisalux.com AEAS / BAES

 Open the catalog to page 55
Universal Catalog-71

+Info *XNAD www.daisalux.com AEAS / BAES

 Open the catalog to page 71
Universal Catalog-75

+Info *IZAR www.daisalux.com

 Open the catalog to page 75
Universal Catalog-81

Hydra + KSP Hydra / KSH Hydra Hydra + KETB Hydra / KEPB Hydra Hydra + KETB Hydra + KSB801

 Open the catalog to page 81
Universal Catalog-89

86 Hydra-RE Hydra-RE + KS Hydra-RE Hydra-RE + KNETB Hydra-RE Hydra-RE + KETB Hydra-RE Hydra-RE + KETB Hydra-RE + KSB801

 Open the catalog to page 89
Universal Catalog-93

Argos + KS Argos / Argos + KSH Argos

 Open the catalog to page 93
Universal Catalog-97

94 Argos-D Argos-D + KTA Argos + RT... Argos-D + KS30 Argos / Argos-D + KS100 Argos

 Open the catalog to page 97
Universal Catalog-105

Nova + KBO Nova + KEB Nova

 Open the catalog to page 105
Universal Catalog-109

Myra + KSP IMNS / Myra + KST IMNS

 Open the catalog to page 109
Universal Catalog-113

Norma + KSP IMNS / Norma + KST IMNS Norma + KENTB Norma Norma + KENTB-Z Norma

 Open the catalog to page 113
Universal Catalog-117

Iris + KSP IMNS / Iris + KST IMNS

 Open the catalog to page 117
Universal Catalog-121

Sol+KENPB Sol+RT.../Sol+KENTB Sol+RT...

 Open the catalog to page 121
Universal Catalog-129

Galia + KSP Galia / Galia + KSH Galia

 Open the catalog to page 129
Universal Catalog-175

Zenit Estanco AEAS / BAES

 Open the catalog to page 175
Universal Catalog-193

Lisu + KENP* Lisu / Lisu + KENT* Lisu

 Open the catalog to page 193
Universal Catalog-252

Software desarrollado para elaborar proyectos de iluminación de emergencia con gran precisión. Permite definir la colocación de las luminarias para cumplir con la norma EN 1838 y otras de carácter específico, optimizando el coste del proyecto. Daisalux, con el objetivo de garantizar la correcta elaboración de sus proyectos, pone a su disposición, de forma gratuita, la realización de los mismos en nuestro departamento especializado ([email protected]). Software developed for producing high precision emergency lighting projects. It can be used to determine the position of the luminaires in...

 Open the catalog to page 252
Universal Catalog-253

www.d a isal ux.com All the models that appear In this catalogue have been created and patented by Daisalux, S.A.U., being of the exclusive use of this company. Daisalux reserves the right to modify the details In this catalogue without previous warning.

 Open the catalog to page 253

All Daisalux catalogs and technical brochures

  1. SPICA Catalogue

    19  Pages

  2. Product Range

    156  Pages

  3. NEWS Ed 01

    21  Pages

Archived catalogs

  1. GALIA

    12  Pages

  2. LECU AND ALZIR

    24  Pages

  3. LISU

    12  Pages

  4. IKUS

    16  Pages

  5. ZINER

    16  Pages

  6. Naos Series

    12  Pages

  7. ATRIA

    16  Pages

  8. VIR SERIES

    16  Pages

  9. NORMA SERIES

    8  Pages

  10. LEDA SERIES

    8  Pages

  11. CLAVO SERIES

    8  Pages

  12. CARRIL SERIES

    4  Pages

  13. ORTO SERIES

    20  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.