1. Catalogs
  2. dacor
  3. Built-In Refrigerator

Built-In Refrigerator

Built-In Refrigerator

Built-In Refrigerator

Product catalog summary
Overview: This planning guide provides specifications and installation instructions for Dacor's 42” and 48” wide built-in refrigerators, including models Ef42bDCb, Ef42bNDb, If42bDCb, If42bNDb, Ef48bDCb, Ef48bNDb, If48bDCb, and If48bNDb.
Specifications:
  • Dimensions: The 42-inch model has a rough-in width of 41 1/2” (1054mm) and the 48-inch model is 47 1/2” (1207mm). The depth from the front of the top grill to the back of the refrigerator chassis is 25 1/4” (641mm).
  • Electrical Requirements: Requires a 115VAC, 60 Hz, 15 Amp circuit breaker. A dedicated non-GFCI circuit is necessary.
  • Water Supply Requirements: Connect to a 1/4” (6mm) copper line with water pressure between 30 and 120 PSI. A shut-off valve is recommended.
Installation Considerations:
  • Ensure a minimum of 2 1/2” (64mm) space between the refrigerator doors and a corner wall for door swing.
  • Follow local plumbing codes and use a drilled saddle valve for water connection.
Custom Overlay Panels:
  • Overlay models use decorative panels for a seamless look. Panels include a decorative front panel, a spacer panel, and a backer panel.
  • Custom handles should be installed before panel assembly, with larger D-style pulls recommended.
Important Notes:
  • Specifications are subject to change without notice.
  • Do not use single pull knobs on built-in refrigerators.
See more

Catalog excerpts

Built-In Refrigerator-1

112905 1/3 P > RODUCT D > IMENSIONS ◊ The depth from the front of the top grill (w/o decorator panel) to the back of the refrigerator chassis is 25 1/4 (641mm).Ԣ׊ The depth from the rear of the top grill to the back of the refrigerator chassis is 23 13/16 (605mm).Ԣ׊ The power cord is 40 (1016mm) long. Ԣ׊ The height from the top of the top grill to floor with the leveling legs in the down position is 83 3/8 (2118mm) Ԣ׊ The height from the top of the top grill to floor with the leveling legs in the fully extended position is 84 5/8 (2149mm) Ԣ׊ The chassis width from the chassis edge to the chassis edge for 42-inch is model 41 1/4 (1048mm), 48-inch is model 47 1/4Ԕ (1200mm).◊ The overall width from the trim edge to the trim edge for 42-inch model is 42 1/16 (1068mm), 48-inch model is 48 1/16Ԕ (1221mm). AӔ Electrical 74Ԕ2 6Ԕ3 75 1/2Ԕ 83 3/4 D > NOTE: More clearance may be required if using an overlay panel or custom handles. OOR S > WING D > IMENSIONS The area to the left and the right of the appliance must permit both doors to open to a minimum of 90԰. Allow a minimum of 2 1/2 (64mm) space between the side of the refrigerator doors and a corner wall. Water Supply 24Ԕ W > ATER S > UPPLY R > EQUIREMENTS ModelRough-In Width AӔ > 42-Inch41 1/2Ԕ (1054mm)48-Inch47 1/2Ԕ (1207mm) E > LECTRICAL R > EQUIREMENTS A 115VAC, 60 Hz, 15 Amp circuit breaker and electrical supply are required. A separate dedicated non-GFCI circuit, servicing only this appliance, is required.Your Dacor Cold water supply > IMPORTANT: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. ◊ All installations must meet local plumbing code requirements.◊ Connect to 1/4 (6mm) copper line to the house cold fresh water supply.Ԣ׊ Use a shut off valve between the refrigerator and supply. The shut off valve should be a drilled saddle valve.◊ Do not use a self-tapping valve which reduces water flow and clogs more easily.◊ Route the water line within 3-1/2 (89mm) of the rear wall and no higher than 3Ԕ (76mm) from the floor. ◊ Allow a minimum of 24 (610mm) dimeter service loop of copper tubing outside the wall or floor for easy connection to the water supply. Ԯ Connect the ice maker to a cold water line with water pressure between 30 and 120 PSI. If you have any questions about your water pressure, call your utility company. IMPORTANT: Built-In refrigerator is equipped with a 40 (1016mm) 3-prong grounded power cord, which must be plugged into a 3-prong grounding-type non-GFCI wall receptacle. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. See ԓRough-In Dimensions for location of the electrical supply. Ԣ׊ In homes with a Reverse Osmosis water treatment system, remove the water inlet connector from the yellowӔ valve and attached to the blueӔ valve. Make sure the water filter bypass plug is in place. Web: http://www.Dacor.com Corporate Phone: 800-793-0093Specifications are subject to change without notice.See installation instructions for additional details.

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.