1. Catalogs
  2. Dachziegelwerke Nelskamp
  3. Laying instructions and program overview

Laying instructions and program overview

Laying instructions and program overview
1 / 64 PagesView full catalog

Laying instructions and program overview

Product catalog summary
Overview: The document provides comprehensive instructions for laying concrete and clay roofing tiles, emphasizing compliance with NELSKAMP manufacturer's guidelines, roofing trade rules, and German Construction Contract Procedures (VOB). It includes product specifications, laying instructions, and CAD data.
Product Specifications: Various tile types are detailed, including NIBRA® hollow interlocking tiles, twin trough gutter tiles, and flat tiles, with specific dimensions and requirements. The document also covers the color range for concrete roofing tiles, noting potential deviations due to printing methods.
Laying Instructions: Instructions for laying different tile types, such as Finkenberger pantiles, are provided. The document specifies minimum overlap based on roof pitch and includes technical data like tile dimensions, weight, and coverage requirements.
Surface Treatments: The ClimaLife surface treatment is highlighted for its self-cleaning properties and environmental benefits through photocatalysis. LONGLIFE coatings are noted for color fastness and abrasion resistance.
Roof Pitch and Overlap: Guidelines for determining minimum overlap based on roof pitch are provided, with additional measures for pitches below the regular roof pitch. A reference table for values is included, emphasizing adherence to manufacturer instructions.
Accessories and Additional Measures: The use of accessories such as ridge tiles, storm clips, and eaves elements is outlined. Additional measures for different roof pitches, including underlayment and undercover requirements, are discussed.
Environmental Considerations: ClimaLife tiles are noted for their air-cleaning ability by neutralizing pollutants, ideal for urban environments. The role of titanium oxide and the benefits of rain in this process are explained.
Technical Data and Installation: Technical data for Finkenberger pantiles, including dimensions, weight, and material requirements, is provided. Installation instructions cover lath sizes, storm clip usage, and eaves design.
Specifications: Detailed specifications for laying Kronen pantiles and S pantiles, including necessary substructures and materials, are outlined. Vent cross-section requirements at the eaves and ridge are detailed according to DIN 4108-3 standards.
Procedures: Installation instructions for step tiles, walking grids, and snow stop tiles are provided, with guidelines for fastening shed roof tiles and using storm clips for wind protection.
Norms and Standards: Several DIN standards, including DIN 18160-5 and DIN EN 516, are referenced, ensuring compliance with German roofing trade rules.
Recommendations: Recommendations for counter-lath thickness based on rafter length and the use of high-level gutters for flat roof pitches below 22° are given. The use of storm clips and recommended materials and dimensions for roofing components are detailed.
Key Data from Tables and Diagrams: Tables detailing nominal cross-sections for support laths, recommended counter-lath thickness, and covering lengths based on roof pitch are included. Diagrams for laying instructions highlight the importance of checking dimensions before installation.
Production and Contact Information: The document lists six production locations in Germany for concrete and clay roof tiles, providing contact details for each site, emphasizing logistical efficiency and environmental considerations.
See more

Catalog excerpts

Laying instructions and program overview-1

Laying instructions and program overview Concrete roofing tiles/Clay roof tiles

 Open the catalog to page 1
Laying instructions and program overview-2

Content Concrete roofing tiles The complete range of products for each concrete roofing tiles and clay roof tiles can be found on the Internet oron the NELSKAMP data service CD. Product specifications, laying instructions and CAD data are available here. 57 NIBRA® hollow interlocking tile H 14 Manufactured according to DIN/EN 490/491 4 The concrete roofing tile range of colours 62 NIBRA® hollow interlocking tile H 10 6 Concrete roofing tile surfaces 67 Twin trough gutter tile D 15 Ü 6 Regular roof pitch/Roof pitch limits/ Minimum overlap 72 Twin trough gutter tile D 13 7 The new concrete roofing...

 Open the catalog to page 2
Laying instructions and program overview-3

The concrete roofing tile range of colours copper brown dark brown slate grey autumn colours moss green brown (ClimaLife) cement-grey (ClimaLife) granite (ClimaLife) Concrete roofing tiles and their colours. Finkenberger pantile CLIMALIFE red brown cement-grey granite LONGLIFE tile red dark brown black moss green blue granite SG = SELF-CLEANING tile red copper brown dark brown slate grey black mid-grey new red bordeaux red granite autumn colours TOP 2000 S tile red dark brown slate grey black new red granite 4 Sigma pantile Kronen pantile Deviations are possible in the colours for reasons of...

 Open the catalog to page 3
Laying instructions and program overview-4

ClimaLife The new concrete roofing tile surface Concrete roofing tile surfaces TOP 2000 S Self-cleaning With the same colour coating, LONGLIFE concrete roofing tiles have advantages over SG concrete roofing tiles due to the smooth, micro-concrete surface. Trees clean the air. Now roof pantiles* do the same. Colour fastness SG and LONGLIFE coatings have the highest degradation reserves UV and weathering in terms of colour fastness. Abrasion resistance The coating on SG and LONGLIFE concrete roofing tiles is very hard-wearing. These advantages are further optimised by the micro-concrete surface....

 Open the catalog to page 4
Laying instructions and program overview-5

Laying the Finkenberger pantiles. year arra nt Technical data Roofing tile Manufacturer Overall length Minimum overlap Finkenberger pantile Nelskamp (D) ~ 42.0 cm RP > 30° = 7.5 cm RP 22 - 30° = 8.5 cm RP < 22° = 10.0 cm Overall width ~ 34.0 cm Covering length ~ 31.4 - 34.5 cm (depending on roof pitch) Covering width ~ 30.0 cm 2 ~ 10.0 pieces Requirement per m Weight per tile ~ 4.6 kg ~ 46.0 kg Weight per m2 Regular roof pitch 22° The colours that are available can be found on page 4-5. The complete range of moulded bricks and accessories can be found on page 122. Covering widths Gable tile for...

 Open the catalog to page 5
Laying instructions and program overview-6

Laying the Finkenberger pantiles. Roof lathing in conjunction with ridge flaps (dry ridge) Aeration and ventilation in steep roof Supporting laths: The following min. cross-sections must be used: (rules for roofing, notes on wood and timber materials) Nom. cross-sections Rafter intervals Sizing class of support laths (unit spacing) 30 x 50 mm ≤ 80 cm S 10 40 x 60 mm ≤ 100 cm S 10 1) The vent cross-section at the eaves should be at least 200 cm2/m of eaves. 2) The vent cross-section at the ridge or crest should be at least 0.5‰ of the total corresponding roof area, though at least 50 cm2. Counter-laths:...

 Open the catalog to page 6
Laying instructions and program overview-7

Laying the Sigma pantiles. year arra nt Technical data Roofing tile Manufacturer Overall length Minimum overlap Sigma pantile Nelskamp (D) ~ 42.0 cm RP > 30° = 7.5 cm RP 22 - 30° = 8.5 cm RP < 22° = 10.0 cm Overall width ~ 33.2 cm Covering length ~ 31.4 - 34.5 cm (depending on roof pitch) Covering width ~ 30.0 cm 2 ~ 10.0 pieces Requirement per m Weight per tile ~ 4.3 kg ~ 43.0 kg Weight per m2 Regular roof pitch 22° The colours that are available can be found on page 4-5. The complete range of moulded bricks and accessories can be found on page 122. Covering widths Gable tile for counter-laths...

 Open the catalog to page 7
Laying instructions and program overview-8

Laying the Sigma pantiles. Aeration and ventilation in steep roof Supporting laths: The following min. cross-sections must be used: (rules for roofing, notes on wood and timber materials) Nom. cross-sections Rafter intervals Sizing class of support laths (unit spacing) 30 x 50 mm ≤ 80 cm S 10 40 x 60 mm ≤ 100 cm S 10 1) The vent cross-section at the eaves should be at least 200 cm2/m of eaves. 2) The vent cross-section at the ridge or crest should be at least 0.5‰ of the total corresponding roof area, though at least 50 cm2. (according to DIN 4108-3) Counter-laths: Rec. thickness of counter-laths...

 Open the catalog to page 8
Laying instructions and program overview-9

Laying the Kronen pantile. year arra nt Technical data Roofing tile Manufacturer Overall length Minimum overlap Kronen pantile Nelskamp (D) ~ 42.0 cm RP > 30° = 7.5 cm RP 22 - 30° = 8.5 cm RP < 22° = 10.0 cm Overall width ~ 34.0 cm Covering length ~ 31.4 - 34.5 cm (depending on roof pitch) Covering width ~ 30.0 cm 2 ~ 10.0 pieces Requirement per m Weight per tile ~ 4.7 kg ~ 47.0 kg Weight per m2 Regular roof pitch 22° The colours that are available can be found on page 4-5. The complete range of moulded bricks and accessories can be found on page 122. Covering widths Gable tile for counter-laths...

 Open the catalog to page 9
Laying instructions and program overview-10

Laying the Kronen pantile. Aeration and ventilation in steep roof Supporting laths: The following min. cross-sections must be used: (rules for roofing, notes on wood and timber materials) Nom. cross-sections Rafter intervals Sizing class of support laths (unit spacing) 30 x 50 mm ≤ 80 cm S 10 40 x 60 mm ≤ 100 cm S 10 1) The vent cross-section at the eaves should be at least 200 cm2/m of eaves. 2) The vent cross-section at the ridge or crest should be at least 0.5‰ of the total corresponding roof area, though at least 50 cm2. (according to DIN 4108-3) Counter-laths: Rec. thickness of counter-laths...

 Open the catalog to page 10
Laying instructions and program overview-11

Laying the S pantiles. year arra nt Technical data Roofing tile Manufacturer Overall length Minimum overlap S pantile Nelskamp (D) ~ 42.0 cm RP > 30° = 7.5 cm RP 22 - 30° = 8.5 cm RP < 22° = 10.0 cm Overall width ~ 33.2 cm Covering length ~ 31.4 - 34.5 cm (depending on roof pitch) Covering width ~ 30.0 cm 2 ~ 10.0 pieces Requirement per m Weight per tile ~ 4.7 kg ~ 47.0 kg Weight per m2 Regular roof pitch 22° The colours that are available can be found on page 4-5. The complete range of moulded bricks and accessories can be found on page 122. Covering widths Gable tile for counter-laths 30 302...

 Open the catalog to page 11

All Dachziegelwerke Nelskamp catalogs and technical brochures

  1. 2power

    1  Page

  2. 2Power

    4  Pages

  3. MS 5 PV

    4  Pages

  4. zubehoer_allg

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.