Hot Water Storage Tanks - 1

Data Specification Hot Water Storage Tanks Hot Water Storage Tanks Coil Tanks and Volume Tanks of 300-750 litres 300 Hot Water Storage Tank 1: 300/20 Insulated, 300 litre coil tank with 20 m hot water coil and two mounted thermometers. Outlet for two immersion heaters 2”. Connection 1¼”. Outer housing: sheet metal. Insulation: PUR Hot Water Storage Tank 2: 300 Insulated, 300 litre volume tank with two mounted thermometers. Outlet for one immersion heater 2”. Connection 1¼”. Outer housing: sheet metal. Insulation: PUR 500 Hot Water Storage Tank 1: 500/25 Insulated, 500 litre coil tank with 25 m hot water coil. Outlet for two immersion heaters 2”. Outer housing: sheet metal. Insulation: PUR 500/50 Insulated, 500 litre coil tank with 2x25 m hot water coils. Outlet for one immersion heater 2”. Outer housing: sheet metal. Insulation: PUR CTC’s hot water storage tanks are designed for almost CTC 750/50–75 has a volume of 750 litres and contains all types of energy sources. They are available in several 2-3 finned copper coils measuring 25 metres each. models and sizes, and can also be combined to fit most heating systems and properties. All the tanks are well- Hot Water Storage Tank 2: 500 Insulated, 500 litre volume tank. Outlet for two immersion heaters 2”. Outer housing: sheet metal. Insulation: PUR insulated with polyurethane/mineral wool for the lowest possible energy loss. CTC Hot Water Storage Tank 1 - coil tanks for efficient DHW heating. 750 Hot Water Storage Tank 1: 750/50 Insulated, 750 litre coil tank with 2x25 m hot water coils. Outlet for three immersion heaters 2”. Outer housing: impactresistant plastic sheet. Insulation: mineral wool. 750/75 Insulated, 500 litre coil tank with 3x25 m hot water coils. Outlet for one immersion heater 2”. Outer housing: impactresistant plastic sheet. Insulation: mineral wool. Hot Water Storage Tank 2: 750 Insulated, 750 litre volume tank. Outlet for one immersion heater 2”. Outer housing: impact-resistant plastic sheet. Insulation: mineral wool. Accessories: CTC Immersion Heater 3 kW with control box CTC Immersion Heater 6 kW with control box CTC Immersion Heater 9 kW with control box CTC Thermowell 160, bushing 3/4” CTC Drainage Valve, 3/4” CTC Thermometer 0-120 ˚C Part Number: DN50/G2”. 400/230 V Inactive 145 mm. Insertion length approx. 30 cm DN50/G2”. 400/230 V Inactive 145 mm. Insertion length approx. 40 cm DN50/G2”. 400 V Inactive 145 mm. Insertion length approx. 40 cm Thermowell with 3/4” bushing for connecting of sensors 500-750 For 500-750. Drainage valve 1/2” with bushing 3/4” For 500-750. Thermometer with thermowell and 3/4” bushing Available in three sizes (300, 500 and 750 litres) and five different models. CTC’s tanks store radiator water instead of hot tap water in order to ensure optimal operation of the heat pump and that you always have fresh hot water. DHW heating is accomplished via finned CTC 300/20 is able to cover the DHW needs of an average-sized house. CTC 500 is able to cover the DHW needs of up to 10 apartments and CTC 750 up to 15 apartments. They can also be cascade-connected in situations where the DHW need is greater. CTC Hot Water Storage Tank 2 - a series of volume tanks for hot water storage. The hot water storage tanks are available in three sizes (300, 500 and 750 litres) and can be interconnected to achieve the desired storage volume. copper coils, which are effectively heated by the radiator A hot water storage tank is necessary for wood boilers in order to store energy, since woodboilers often produce CTC 300/20 has a volume of 300 litres and contains a finned copper coil measuring 20 m. CTC 500/25–50 has a volume of 500 litres and contains 1-2 finned copper coils measuring 25 m. more energy than can be consumed at any given time. The size of thetank depends on the size and type of wood boiler installed. In most cases, a modern wood boiler requires a storage volume of at least 1,500 litres. Key features • Suitable for most energy sources • Ensures optimal heat pump operation • Well-insulated for lowest possible energy loss • Available in three sizes: 300, 500 and 750 litres • Hot water heated via highly effective finned copper coils Go Geothermal Ltd Ridgeway, Newton Aycliffe County Durham, DL5 6SP Tel: 0

Open the catalog to page 1
Hot Water Storage Tanks - 2

Dimensions Diagram Dimensions Diagram 300 300/20 CONNECTIONS: EQUIPMENT: 1. Temperature sensor A. Thermometers thermowell 0 7. B. Drain cock 2. Immersion heater outlet - DN50 C. Hot water coil (0 22) 3. Draining - DN15 4. Supply from heat source - DN32 5. Return to heat source - DN32 6. DHW 7. Expansion - DN25 8. 0 22 Cw/DHW/conn. bivalent mixing valve 9. Thermometer - DN20 10. Return pipe radiator - DN32 11. Riser pipe radiator - DN32 2. Supply from heat source - DN50 3. Thermometer - DN20 4. Immersion heater outlet - DN50 5. Return to heat source - DN50 6. Draining - DN20 7. Extra - DN50...

Open the catalog to page 2

All CTC Enertech Group catalogs and technical brochures

  1. CTC CombiAir

    6 Pages

  2. Technical Data

    20 Pages

  3. EcoAir 400

    4 Pages

  4. EcoAir 600M

    2 Pages