Electrical Data Emersion heater (steps of 0.3kW) Max immersion heater output @ fuse size 16 / 20 / 25A Operating current Operational data for heat pump Output from compressor Output from compressor Output from compressor 1) @5/35 | 5/45 Max. operating current Compressor Heating system Water volume. thermal store (V) Max. operating pressure. thermal store (PS) Max. temperature. thermal store (TS) Heating system. min. flow Heating system. nominal flow 2) Brine system Water volume (V) Measurements of EcoHeat 300 temp. (TS) Brine system min./max. The Next Generation of Ground Source Heat Pump The EcoHeat 400 has a number of new components and controls including our newly developed refrigerant circuit, highly efficient compressor and variable flow control which incorporates a speed-control low-energy pump. The compressor and refrigeration components are now sealed in a separate, sound insulated unit. This provides a dramatic reduction in the sound output. The compressor unit can be removed for easy installation and speedy maintenance. The collector circuit can be easily connected to the right, left or on the back of the heat pump using the supplied flexible hoses. A new engineering design enables us to increase the Key features • Record mode: 5.04 in COP (efficiency) • Up to 80% lower heating costs • Meets BBR rules • Colour touch screen • With Energy Flex - total flexibility to connect to other heat sources withEnergy Flex - total flexibility to connect to other heat sources Heat pump connection solution of cold side Brine-level vessel Brine system nominal flow, ∆t = 3 ˚K Brine system pump 193 Hot water system Water volume, hot water coil (V) Max operating pressure, hot water coil (PS) Max temperature, hot water coil (TS) Refrigerant quantity (R407C) Interupt value switch HP - Safety valve for the cold side, 3 bar ˚C 110 - Safety valve for the water consumption, 9 bars EN14511:2007, incl. heating medium pump and brine pump ∆t = 10 K and 0/35 ˚C heat pump operation 3) SVEP tested @ EN255 654 - Installation and Maintenance Instructions 10 Width x Height x Depth Minimum ceiling height - Flow sensor diagram in the Pipe installation chapter s ee Other data Energy Flex gives you the freedom to include other energy sources such as solar heating or biomass. You can even control your pool heating. At CTC, we have chosen a proprietary technology that provides much more even heat without temperature fluctuating up and down. Radiators and underfloor heating will always get the right temperature thanks to temperature control mixing valve. Wireless room sensors are available as an exceptionally wise accessory. Brine system min. flow, ∆t = 5 ˚K The touch screen has clear symbols with text that makes it easy to adjust the heating and hot water or to retrieve information about the system operation. Included in this control package is an integrated internet or mobile network that allows you monitor and control your heating remotely. heat pump hot water delivery. This solution gives the user, legionella protection for hot water production and a higher capacity DHW with lower storage volume. This innovative solution produces hot water as and when it is used. Brine pump speed adjustment EcoHeat 400 is the new generation of ground source heat pump, which has achieved our highest performance COP 5.04. Brine system min./max. pressure (PS) Installation Kit 1 (Expansion vessel 18 l, angular coupling, circulation pump, thermostatic mixing valve, filling coupling brine 520-G25) Installation kit 2 (Expansion vessel 18 l, angular coupling, circulation pump, thermostatic mixing valve, filling coupling brine 520-G32) Expansion vessel G20 18 L, angular coupling, gasket Pump Stratos 25/1-8 Para 1. Expansion connection clamping ring 22 7. From rock / ground Ø28 (right, left and Pump Stratos Para 25/1-12 1. Expansion connection clamping ring 22 2. Connecting waste pipe clamping ring 22 rear) As a rock / ground Ø28 (right, left 2. Cold water connection Ø22 3. Connecting waste pipe clamping ring 22 Replenishment Lead a G25 and rear) 4. Hot water Ø22 3. Cold water connection Ø22 Replenishment Lead 2 G32 5. Radiator Supply clamping ring 22 8. Lift sleeve Rp 3 / 4 ” 6. Hot water Ø22 4. Radiator Return Ø22 Flow monitor Internet Monitoring SMS Control Wireless room sensors 7. From rock / ground Ø28 (right, left and rear) As a rock / 9. Connection of external systems(tube 5. Radiator Supply clamping ring 22 ground Ø28 (right, left and rear) 8. Lift sleeve Rp 3 / 4 ” penetrations) 6. Connection of external systems (tube penetrations) 9. Radiator Return Ø22 Technical data Dimensions W x H x D Electrical data Rated output power Tillsatsel (adjustable) 11,7 kW 13,4 kW For more information about ctc’s product range visit: 12,6 kW 0,3-9 kW Ten Acres, Berry Hill Industrial Estate, Droitwich Spa, Worcestershire WR9 9BP Power consumption at the compressor 35/50°C Tel: +44 (0) 1905 COP, enl EN255 Emitted output compressor at 0/35 Emitted output compressor at 0/35 and 0/45 2) 140995 CTC EcoHeat.indd 1 Rated power Ground Source Heat Pump EcoHeat 400 is the new generation of ground source heat pump, which has achieved our highest performance COP 5.04. EcoHeat 400 TECHNICAL DATA 17005539-08-12 Subject to alterations in design.
Open the catalog to page 1Electrical Data Emersion heater (steps of 0.3kW) Max immersion heater output @ fuse size 16 / 20 / 25A Operating current Operational data for heat pump Output from compressor Output from compressor Output from compressor 1) @5/35 | 5/45 Max. operating current Compressor Heating system Water volume. thermal store (V) Max. operating pressure. thermal store (PS) Max. temperature. thermal store (TS) Heating system. min. flow Heating system. nominal flow 2) Brine system Water volume (V) Measurements of EcoHeat 300 temp. (TS) Brine system min./max. The Next Generation of Ground Source Heat Pump...
Open the catalog to page 2All CTC Enertech Group catalogs and technical brochures
-
CTC CombiAir
6 Pages
-
Technical Data
20 Pages
-
CTC EcoZenith i255
4 Pages
-
CTC EcoZenith i360
4 Pages
-
Hot Water Storage Tanks
2 Pages
-
EcoAir 400
4 Pages
-
EcoAir 510M EcoAir 520M
2 Pages
-
EcoAir 600M
2 Pages
-
CTC EcoAir 406,408
2 Pages
-
EcoZenith i550 Pro
2 Pages