Overview: The ENsign range of sewage treatment plants is certified to EN12566-3 and designed according to British Water Loads & Flows Code of Practice. These plants are engineered for durability and efficiency, featuring a minimum wall thickness of 5mm and powered by energy-efficient compressors.
Specifications: The plants are available with gravity and pumped outlets, shallow invert options, and stainless steel fixings. They include a separate de-sludge chamber and are designed for quiet operation with low running costs. The treatment plants are available for populations ranging from 6 to 50 PE, with a BOD of 15mg/litre and a hydraulic daily load of 1.2m3/day to 10m3/day. The material used is GRP, and the plants have passed watertightness, crushing resistance, and treatment efficiency tests.
Features: The ENsign plants are equipped with compressor alarms and offer a full technical design service. They are designed to be environmentally friendly, with no smell or foul odors, low carbon footprint, and no electricity requirement. The plants are also low maintenance and provide a cleaner garden environment.
Uni:Gem Range: The Uni:Gem range is designed for populations of 6-70 PE and meets EN12566-6 standards for secondary treatment of septic tanks. It features strong moulded 8mm GRP, stainless steel fixings, and a media bed surface area of 310m2 per m3. The range includes silent compressors, easy de-sludge access, and low maintenance components.
Environmental Compliance: The document highlights the importance of treating effluent from septic tanks to prevent pollution, as mandated by the Environment Agency. The Uni:Gem range addresses this by treating final effluent to prevent watercourse pollution.
Contact Information: CPM Group Ltd provides contact details for sales and manufacturing offices in England, Wales, and Scotland, along with an enquiry form for further assistance.
See more

Catalog excerpts

Septic Tanks-1

Sewage Treatment Plants From 6 – 50PE Uni:6 – 50 [email protected] www.cpm-group.com The ENsign Range of Sewage Treatments Plants is Certified to EN12566-3 and Designed in Accordance with British Water Loads & Flows Code of Practice • Gravity & Pumped Outlet • Shallow Invert 500mm • Invert Risers Available • Very Quiet Running • Low Running Cost • Stainless Steel Fixings • Separate De-sludge Chamber • Ex-stock normally within 72 hours • ENsign Sewage Treatment Plants are extremely strong engineered to a minimum wall thickness of 5mm both internally and externally • Powered by Energy Efficient Compressors • Pumped Outlets are Pedrollo pumps • Compressor Alarms Are Standard • Full Technical Design Service Available Hydraulic daily load 1.2m3/day-10m3/day Material: GRP Watertightness (water test): Pass Crushing resistance: Pass Treatment efficiency: BOD: Pass TSS: Pass NH4: Pass Tested to BSEN12566-3: Aachen Germany 19591 MARSH CPM ENSIGN A4 4pp FLYER.indd 1

 Open the catalog to page 1
Septic Tanks-2

Polylok © Green Filter Septic Tanks The Green Clean Solution For A Dirty Problem No smell & foul odours in the soil & grass Low carbon footprint No electricity Kinder to your local environment No blocked land drains Low ongoing maintenance A cleaner garden for both play & relaxation Spend A Little More Now, Save Thousands In The Future! Also available in durable precast concrete with a 120 year design life that requires no insitu concrete and can be installed in trafficked areas. CPM Group Ltd Head Office, Mells Road,Mells, Nr. Frome, Somerset BA11 3PD 19591 MARSH CPM ENSIGN A4 4pp FLYER.indd...

 Open the catalog to page 2
Septic Tanks-3

Uni:Gem 6-70PE Range For Populations 6-70PE Designed To Meet EN12566-6 Secondary Treatment For Septic Tanks 20:30:20 There are nearly a million septic tanks installed currently in the United Kingdom, CIRIA technical note 146 reported that several thousand septic tank soak-aways fail every year. Now the Environment Agency has recently announced that “You must make sure that the effluent from your septic tank is further treated, for example by a form of secondary treatment or reed bed, before you dispose of it to a watercourse. You may be able to dispose of the effluent by soaking it away to ground...

 Open the catalog to page 3
Septic Tanks-4

Sales – England & Wales - T: 01179 812791 F: 01179 814511 Sales – Scotland - T: 01698 386922 F: 01698 387167 Sales Office and Manufacturing Head Office, Mells Road, Mells, Nr. Frome, Somerset BA11 3PD T. 01179 814500 F. 01179 814511 19591 MARSH CPM ENSIGN A4 4pp FLYER.indd 4 Scottish Sales & Manufacturing CPM Group Limited Main Street, Newmains, Wishaw ML2 9BG T. 01698 386922 F. 01698 387167

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.