Vitesse Plus Lighting Control System A new era of lighting control for education, commercial and retail spaces
Open the catalog to page 1Simple to install With plug-in modular components the new Vitesse Plus 7-channel system is easy to install and set up, saving time and money. Flexibility, Reliability and Simplicity at Your Fingertips CP Electronics has built a global reputation for innovative, reliable, energy-saving lighting control systems. Now new Vitesse Plus heralds the next step in lighting control, with simple commissioning and total flexibility. It’s a full 7-channel system that’s ideal for education, commercial and retail spaces - anywhere that needs to control energy costs without affecting user convenience....
Open the catalog to page 2Feature-packed to suit your needs ● Graduated Dimming Open Port Function Corridor Hold Scene Setting SELV Switching Emergency Lighting Test Control at your fingertips The Vitesse Plus handset offers access to a menu of pre-set configurations to set up spaces quickly and intuitively. Features like corridor hold and graduated dimming are easy to set up and control. See page 5
Open the catalog to page 3Innovative products Choose the ideal combination of lighting, presence and absence detectors, switches and scene-setting plates to suit your environment; Vitesse Plus seamlessly controls them all. See pages 13–16
Open the catalog to page 4Introduction to Vitesse Plus How Pre-set Configurations Work In the past, programming the right configuration for a specific application has required specialist skills. Not any more: the pre-set configurations within the latest Vitesse Plus system are easily accessed by the installer and end user. Match pre-sets to your application Config 13 – Classroom with 3 rows of luminaires working in absence mode. Whiteboard on channel 5. Detector/scene plate inputs SW1 Whiteboard Switch If using 2 PIRs instead of a microwave detector, the PIR closest to the window will reference LUX and should be...
Open the catalog to page 5Introduction to Vitesse Plus Graduated dimming Corridor hold SELV switching Emergency lighting test Open port function Scene setting Feature Packed Graduated dimming Emergency lighting test The lighting within a space dims progressively from the source of natural illuminance in response to changes in natural light levels. This maximises the use of daylight within a space and minimises energy consumption and over-lighting of the space. Dedicated SELV input allows for a local emergency test on the LCM. This can be linked across a number of LCMs to allow emergency test of a large open plan...
Open the catalog to page 6Introduction to Vitesse Plus Simple Installation and Connectivity Versatile wiring connections Vitesse Plus has been designed for hassle-free wiring on-site. Vitesse Plus has been designed with the installer in mind and provides easy installation options for all mounting locations. The mains input is connected using the spacious wiring compartment; and control inputs and outputs are pluggable using industry standard connectors as shown in the typical layout above. Spacious wiring compartment Marco clip mounting Pluggable SELV connections Slab mounting Visit www.cpelectronicscorporate.com...
Open the catalog to page 7Education Designed to help the education sector meet emerging legislative requirements for classroom lighting control. Config 10 – Classroom with 3 rows of luminaires working in absence mode. Whiteboard on channels 1, 2 and 3. Detector/scene plate inputs SW1 If using 2 PIRs instead of a microwave detector, the PIR closest to the window will reference LUX and should be connected to Input 1. L Whiteboard Switch Each switch operates luminaires within the same colour dashed line Switches and dims the whiteboard luminaires independently within the same colour dashed line Luminaires daylight link...
Open the catalog to page 8Graduated dimming – The lighting within a space dims progressively from the source of natural illuminance in response to changes in natural light levels. This maximises the use of daylight within a space and minimises energy consumption and over lighting of the space. (Please see page 19). Absence recovery – This initiates presence mode in absence applications after a detector timeout period has elapsed. The default for this is 10 seconds. There is also a fade time with a pre-set default of 5 minutes, this means that any dimmable luminaires will dim down to 20% to give a visual indication...
Open the catalog to page 9Commercial/Retail Perfect stand-alone solution for small to medium-sized commercial spaces, and the changeable retail model. Config 1 – 4 cellular offices individually controlled with a presence detector and or manual switch in each. Detector/scene plate inputs Each switch operates luminaires within the same colour dashed line Upon exiting the space any luminaires left on will switch off after an adjustable time out period Switch inputs Dimmable luminaires – 20% Emergency luminaires Luminaires daylight link – window row only dimmable SW1 SW4 Emergency Lighting Test Visit...
Open the catalog to page 10Corridor hold – For safety reasons, lights are kept on for entry exit routes, even when an adjacent area is unoccupied. Scene setting – Scene selection allows the recall of pre-programmed lighting levels to create different moods or to suit different uses within an environment. Master on switch – This switch turns on all the luminaires connected to an LCM regardless of channel or input arrangement. Open port function – No need to access the LCM to set the pre-set configuration. Modular mechanics – Luminaire leads, presence detectors and scene plates simply plug into the LCM making Vitesse...
Open the catalog to page 11System Products Vitesse Plus Lighting Control Modules The latest generation of Vitesse Plus LCM has been engineered to adapt to changing environments. With 7 channels and 12 outputs, the installation process is simplified. Up to 6 PIRs or 3 microwave detectors can be connected to the Vitesse Plus LCM, maximising the capacity to save energy and money. With 18 SELV connections and the ability to facilitate graduated dimming, the Vitesse Plus LCM takes lighting control to the next level of functionality. Order Code Lighting control module with switched output – 12 channel 12 outputs 7 channels...
Open the catalog to page 12All CP Electronics catalogs and technical brochures
-
Vitesse Modular - Issue 2.1
24 Pages
-
Green-i Ceiling PIR Sensors
2 Pages
-
Rapid - Issue 3.2
10 Pages
-
Overview Product Brochure
16 Pages
-
Green-i - Issue 1.5
56 Pages
-
Products Catalogue - Issue 5.3
128 Pages
-
Products Catalogue - Issue 5.1
116 Pages
-
Newsletter June 2014
4 Pages
-
Technical Brochure Issue 1.0
6 Pages
-
Newsletter Issue 5 Xmas
4 Pages
-
Newsletter Version 4
5 Pages
-
Vitesse Modular - Issue 1.2
8 Pages
-
Newsletter May 2013
4 Pages
-
Energy Saving Controls
96 Pages
-
MWS1A brochure
2 Pages
-
Green-i Brochure
52 Pages
-
D-Mate? Brochure - Issue 1.0
8 Pages
Archived catalogs
-
products catalogue - issue 4.2
88 Pages
-
Green-i Brochure
8 Pages
-
Products Catalogue - Issue 4
88 Pages
-
vitesse modular
18 Pages
-
green eye
1 Pages
-
green eye
8 Pages
-
green eye
1 Pages
-
Green eye
8 Pages