ACCES CONTROL SYSTEMS
12Pages

{{requestButtons}}

Catalog excerpts

ACCES CONTROL SYSTEMS - 1

ACCES CONTROL SYSTEMS

Open the catalog to page 1
ACCES CONTROL SYSTEMS - 2

Security standards For Fixed Ladders French Standard NF E S5-016 Elements of Industrie! plants Fixed metal ladders it# or without cage Conception - Installation - Tests The Rules of Safety For Fixed Ladders Workplace (Health, Safety and Welfare) Regulations 1992 provide legal requirements for safe passage in the work place. For Access Control Systems Access control systems provide security at work, unauthorized access by the general public and protection of goods which complies with the security rules described hereafter. The recommendations contained within 'his standard include for the...

Open the catalog to page 2
ACCES CONTROL SYSTEMS - 3

Access-control systems for fixed ladders with cage m. Access control door with hatchcover for any type of standard ladder with cage, fixed at the bottom of the ladder preventing unauthorized people from climbing. ■ Locking by tailed lock ■ Unlocking by pushing the release pedal on the hatchcover with the foot when descending the ladder. ■ Spring-loaded Hinges Industry Engineering offices Architects, control offices Commercial and industrial buildings Pylons, road signalization structures Silos, water tanks Travelling cranes, gantries • One way access (climbing and descending with the same...

Open the catalog to page 3
ACCES CONTROL SYSTEMS - 4

With opening on the left hand side CEC110A : Hinges on the right hand side, self-closing CEC120A : Hinges on the left hand side, self-closing CEC310A : Hinges on the right hand side, for fire exit CEC320A ; Hinges on the left hand side, for fire exit i Anti-intrusion rear bottom sheet for the ladder i Anti-intrusion side panels for the ladder i Perforated metal sheet around the cage of the ladder On a standard ladder (400 mm width between the uprights), for other dimensions please fill in the dimensions sheet at the end of the brochure. • by welding on a steel ladder • by bolting on a steel...

Open the catalog to page 4
ACCES CONTROL SYSTEMS - 5

Access-control systems for fixed ladders with cage ■ Access control door with hatchcover for any type of standard ladder with cage, fixed at the bottom of the ladder, preventing unauthorized people from climbing. ■ _ocking with tailed lock or padlock • Industry • Engineering offices • Architects, control offices • Commercial and industrial buildings • Pylons road signalization structures • Silos, water tanks • Travelling cranes, gantries • One way access (climbing and descending with the same ladder) Patented Material / The manufacture holds the nght for any modification without prior...

Open the catalog to page 5
ACCES CONTROL SYSTEMS - 6

CEC410A : Hinges on the right hand side, steel galv., lock GEC420A : Hinges on the left hand side, steel galv.. lock CEC410Z : Hinges on the right hand side, steel gaiv., padlock CEC420Z : Hinges on the left hand side, steel galv., padlock CEC410A : Hinges on the right hand side, alu., lock CEC420A : Hinges on the left hand side. alu.. lock CEC413Z : Hinges on the right hand side, alu., padlock CEC423Z : Hinges on the left hand side. alu.. padlock ■ Anti-intrusion side panels for the ladder ■ Anti-intrusion rear bottom sheet for the ladder ■ Perforated metal sheet around the cage of the...

Open the catalog to page 6
ACCES CONTROL SYSTEMS - 7

Access-control systems for fixed ladders with cage ■ Access control door without hatchcover for any type of standard ladder with cage, fixed at the bottom of the ladder, preventing unauthorized people from climbing. ■ Locking with tailed lock or padlock • Industry • Engineering offices • Architects, control offices O Commercial and industrial buildings O Pylons, road signalization structures O Silos, water tanks • Travelling cranes gantries • One way access (climbing and descending with the same ladder) O Multiple access (ladders which are connected together, emergency exit..) 0 The opening...

Open the catalog to page 7
ACCES CONTROL SYSTEMS - 8

CEC510A : Hinges on the right hand side, steel galv.. lock CEC520A : Hinges on the left hand side, steel galv., lock CEC510Z : Hinges on the right hand side, steel galv., padlock CEC520Z : Hinges on the left hand side, steel galv.. padlock CEC510A : Hinges on the right hand side, alu., lock CEC520A : Hinges on the left hand side, aiu., lock CEC513Z : Hinges on the right hand side, alu., padlock CEC523Z : Hinges on the left hand side, alu., padlock i Anti-intrusion side panels for the ladder i Anti-intrusion rear bottom sheet for the ladder On a standard ladder (400 mm width between the...

Open the catalog to page 8
ACCES CONTROL SYSTEMS - 9

Access-control systems for fixed ladders with cage ■ Access control door with hatchcover for any type of standard ladder with cage, fixed at the bottom of the ladder (at about 2300mm from the floor), preventing unauthorized people from climbing. * Locking with padlock Industry Engineering offices Architects, control offices Commercial and industrial buildings Pylons, road signalization structures Siios, water tanks Travelling cranes, gantries • One way access (climbing and descending with the same ladder) Patented Material I The manufacture holds the right for any modification without poor...

Open the catalog to page 9
ACCES CONTROL SYSTEMS - 10

AC610Z : Hinges on the right hand side, steei galv. AC620Z : Hinges on the left hand side, steel galv. AC613Z: Hinges on the right hand side, alu. AC623Z: Hinges on the left hand side. alu. ■ i o the left land side Anti-intrusion rear bottom sheet for the ladder Anti-intrusion side panels for the ladder ! Perforated metal sheet around the cage of the ladder On a standard ladder (400 mm width between the uprights), for other dimensions please fill in the dimensions sheet at the end of the brochure. • by welding on a steei ladder 9 by rivets • by staples on an aluminium ladder > optional...

Open the catalog to page 10
ACCES CONTROL SYSTEMS - 11

Choice of Adaptations Kits Bottom Sheet Bottom Sheet standard steel galvanised ■ Height: 1490 mm ■ Depth : 200 mm ■ Adaptable in width ■ Fixing by rivets (provided) Side brackets Side brackets preventing access to the ladder from behind ■ Height: 3000 mm ■ Depth : 200 mm ■ Fixing by rivets (provided) Perforated Metal Sheet Perforated Metal Sheet, preventing access to the ladder cage ■ Diameter: 710 mm ■ Height : 1000 mm ■ Steel galva. or Alu. ■ Fixing by rivets (provided)

Open the catalog to page 11