video corpo

Conder Separators

Conder Separators

Conder Separators

Product catalog summary
Introduction
Premier Tech Aqua provides Conder Oil Separators for surface water drainage systems to prevent hydrocarbon contamination, essential for pollution prevention and regulatory compliance.
Compliance
These separators adhere to the Environment Agency's PPG guidelines and BSEN-858-1-2 standards, ensuring efficient oil and water separation with minimal environmental impact.
Classes of Separators
  • Class 1: Achieves oil concentration below 5 mg/L, suitable for surface water drains.
  • Class 2: Achieves oil concentration below 100 mg/L, suitable for foul sewers.
Separator Alarms
Legislation mandates oil separators to have an oil level alarm system, requiring regular installation, testing, and servicing.
Types of Conder Separators
  • Bypass Separator: For rainfall rates up to 6.5 mm/hr, suitable for low-risk areas.
  • Full Retention Separator: For full flow from drainage systems, suitable for high-risk areas.
  • Forecourt Separator: Designed for petrol stations, retains up to 7,600 liters of spillage.
  • Wash Down and Silt Separators: Used in car washes, focuses on silt removal.
Specifications and Performance
Each separator type has specific models with varying capacities and dimensions, designed to meet PPG3 guidelines for efficient pollutant separation and retention.
Additional Features
Options include solar-powered systems, GSM alarms, and coalescing filters for enhanced performance and monitoring.
Maintenance
Regular maintenance every six months is required as per Environmental Agency guidelines to ensure optimal performance.
Conder Alarm Systems Overview
All separators must have an alarm system providing visual and audible warnings at 90% oil storage capacity, ensuring timely emptying for effective operation.
Features and Benefits
  • Remote supervisory point installation option
  • Audible and visual alerts
  • Reduces unnecessary waste management visits
  • Easy installation
  • Available in audible, visual, and text message alert formats
Mains Powered System
Ideal for new constructions or sites with straightforward cabling, activating an alarm when hydrocarbons are detected, indicating the need for emptying.
Contact Information
2 Whitehouse Way, South West Industrial Estate, Peterlee, Co Durham, SR8 2RA UNITED KINGDOM.
Phone: +44 (0) 8702 640004 | Fax: +44 (0) 8702 640005 | Email: [email protected]
Website: PREMIERTECHAQUA.CO.UK
See more

Catalog excerpts

Conder Separators-1

OIL/WATER SEPARATORS SROTARAPES RETAW/LIO

 Open the catalog to page 1
Conder Separators-2

Premier Tech Aqua’s range of Conder Oil Separators are for installation on surface water drainage systems and are designed to prevent hydrocarbons (e.g. diesel, petrol, engine oil) from mixing with surface water and entering our drainage systems. Pollution prevention is a critical part of sustainable drainage systems and statutory regulations are in force to control the discharge of hydrocarbons, with severe penalties imposed for non-compliance.

 Open the catalog to page 2
Conder Separators-3

Compliance Premier Tech Aqua’s range of Conder Oil Separators full conform to both the Environment Agency’s latest PPG guidelines and European standard BSEN-858-1-2 and are proven to effectively separate oil and water. Under test, the Conder Bypass performed to less than 1 mg/L and in doing so guarantees minimal environmental impact and ensures public safety. Classes of Separators There are two classes of separators which are dened by performance. Class 1 Class 1 Separators are designed to achieve a concentration of less than 5 mg/L of oil under standard test conditions. These conditions are...

 Open the catalog to page 3
Conder Separators-4

Conder Bypass Separators Premier Tech Aqua’s range of Conder Bypass Separators are used to fully treat all ows generated by rainfall rates of up to 6.5 mm/hr. Conder Bypass Separators are used when it is considered an acceptable risk not to provide full treatment for high ows, for example where only small spillages occur and the risk of spillage is small. Typical Applications • Car parks • Roadways and major trunk roads • Light industrial and goods yards Features and Benets • Innovative design • Compact and easy to handle/install • Fully compliant to the Environment Agency’s PPG3 guidelines Conder...

 Open the catalog to page 4
Conder Separators-5

Conder Full Retention Separators Premier Tech Aqua’s range of Conder Full Retention Separators are designed to treat the full ow that can be delivered by a drainage system, which is normally equivalent to the ow generated by a rainfall intensity of 65 mm/hr. Full Retention Separators are used where there is a risk of regular contamination with oil and a foreseeable risk of signicant spillages. Typical Applications • Sites with a high-risk of oil contamination • Fuel storage depots • Refuelling facilities • Petrol forecourts • Vehicle maintenance areas/workshops • Where discharge is to a sensitive...

 Open the catalog to page 5
Conder Separators-6

Conder Forecourt Separators Conder Forecourt Separators have been designed for specic use in petrol lling stations and other similar applications. The size of this separator has been specically increased in order to retain the possible loss of the contents from one compartment of a road tanker, which could be up to 7,600 litres. Forecourt Separators are an essential infrastructure requirement for all forecourts so as to ensure compliance with both health and safety and environmental legislation. Typical Applications • Petrol forecourts • Refuelling facilities • Fuel storage depot Features and...

 Open the catalog to page 6
Conder Separators-7

Conder Washdown and Silt Separators Premier Tech Aqua’s range of Conder Washdown and Silt Separators are for use in areas such as car washes, pressure wash facilities or other cleaning facilities and must be discharged to the foul water drainage system in accordance with PPG13. Typical Applications • Car wash facilities • Tool hire depots • Pressure washer facilities Features and Benets • Available in 1,2 and 3 stage options • Efcient silt and hydrocarbon removal Performance The Environment Agency’s PPG13 requires that discharge from pressure washers must discharge to a foul drainage system....

 Open the catalog to page 7
Conder Separators-8

Conder Alarm Systems All separators must be tted with an alarm in order to provide visual and audible warning when the level of oil reaches 90% of its storage volume, as required by The Environment Agency’s PPG3. The alarm system will then be triggered to indicate that the separator is in need of immediate emptying, in order to continue effective operation. Solar Powered System (Flashing Beacon) This option requires no mains power supply or any signicant cabling or ducting, making it extremely economical for large sites and retro tting alarms to existing oil separators. A High Intensity Beacon...

 Open the catalog to page 8

Archived catalogs

  1. NSAF range

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.