video corpo

CL2000

CL2000

Product catalog summary
Technical Specifications
  • Surface Deadbolt: The bolt slides on the inside surface of the door and is operated manually via the outside knob after code input, or freely by the inside knob. A surface and mortice mounted keep is provided. The bolt retracts when a valid code is entered and the Blue LED lights up.
  • Mortice Deadbolt: Extends 25mm (1”) beyond the door edge when locked. The bolt retracts upon valid code entry and Blue LED activation.
Functions
  • Code Change Method: Set via keypad using Master Code.
  • Code Free Mode: Set via keypad or key.
Product Dimensions
  • Instructions for retrofitting include removing existing locks, drilling a 20mm hole for cable, and fitting the CL2000 using existing fixings.
Latch Options
  • Light-duty tubular mortice latch with stainless steel latchbolt head and ‘anti-shim’ plunger. The latchbolt retracts upon valid code entry and Blue LED activation. The spring latch automatically locks the door when closed.
  • Backset options include 50mm, 70mm, and 60mm with corresponding hole dimensions.
Key Override
  • The key can open the door on all locks for management functions.
Options
  • Three available options with operations up to 80,000 per set of batteries.
  • Low Battery Warning: Red LED flashes to indicate battery change is needed.
  • Memory stores up to 80 different User Codes.
  • Battery Override: Lock can be opened by attaching a PP3 battery and entering the Master Code.
  • Material: Zinc Alloy, suitable for door thickness 35mm – 60mm.
  • Non-Handed: Fits doors hung on the left or right.
  • Remote Release options for cable or alarm release.
  • Finish: PVD finishes in brushed steel and polished brass.
  • Codes: 4, 5, or 6 digit codes with up to 1,000,000 unique combinations.
  • Standards: Fire Kit Packs for 30 or 60-minute fire doors, tested to BS EN 1634-1:2008.
  • Suitable for internal and external use.
See more

Catalog excerpts

CL2000-1

Surface Deadbolt Bolt slides on the inside surface of the door to lock or unlock. Bolt is moved manually by means of the outside knob after code input and freely by the inside knob at all times. A surface and mortice mounted keep is provided. When a valid code is entered and the Blue LED lights up, the knob will retract the bolt. Mortice Deadbolt Bolt extends 25mm (1") beyond door edge when locked. When a valid code is entered and the Blue LED lights up, the knob will retract the bolt. Tubular Mortice Latch Light-duty with stainless steel latchbolt head, with ‘anti-shim' plunger. When a valid code is entered and the Blue LED lights up, the knob will retract the latchbolt. When the door closes the spring latch will automatically lock the door. Code Change Method Code Free Mode Set via keypad using Set via keypad or key Master Code TECHNICAL SPECIFICATIONS OPTIONS Latch Options: 2 latch options: 50mm (2") backset requires 25 x 72mm (1" x 27/e") hole. 70mm (2%") backset requires 25 x 92mm (1" x 35/e") hole. 60mm (2%") backset requires 25mm (1") hole, 82mm (314") deep. Key Override: The key will open the door on all locks for management functions. For further product model options see price list. 1 Remove existing mechanical digital lock 2 Drill single 20mm (13/16") hole for cable 3 Fit CL2000 on door using existing fixings PRODUCT DIMENSIONS CL2200 CL2255 Options *Codelocks electronic locks offer a two year guarantee and will be repaired, serviced or replaced free of charge if they develop a manufacturing fault. Faults caused by misuse, abuse and/or poor fitting are not covered by the guarantees.

 Open the catalog to page 1

All CODELOCKS catalogs and technical brochures

  1. CL400

    1  Page

  2. CL100

    1  Page

  3. CL4000

    1  Page

  4. CL4000GD

    1  Page

  5. CL600

    2  Pages

  6. CL2200

    4  Pages

Archived catalogs

  1. Product Range

    36  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.