Cobert Delta
6Pages

{{requestButtons}}

Catalog excerpts

Cobert Delta - 1

The importance of choosing well clay roof tile Colour: MEDIEVO

Open the catalog to page 1
Cobert Delta - 2

clay roof tile Subject to specific conditions (see next page) Areas of back overlap very well defined. Maximum leak-proof Assemblies developed for maximum water evacuation. Recessed profile It ensures the correct assembly of the tiles. Double canal profile Regulation: Installation regulation: Impermeability test: Fire resistance: > 150 CYCLES The tile which concludes your best projects Frost resistance: Transverse breaking strengh:

Open the catalog to page 2
Cobert Delta - 3

ARENA OCRE BROWN Clay roof tiles are natural products therefore small variations in colour might occur as a result of the production process. The printing process of this catalogue does not guarantee that printed colours will accurately match to actual roof tile colours.

Open the catalog to page 3
Cobert Delta - 4

Classic ridge Right verge Left verge Universal verge Weight per unit (kg): 3.10 Un./lm: 2.5 Weight per unit (kg): 3.40 Un./lm: 2.5 Weight per unit (kg): 3.40 Un./lm: 2.5 Weight per unit (kg): 3.10 Un./lm: 2.4 Classic 3 ridge junction Half tile Ornamental piece Ventilation tile Lanterne base tile Weight per unit (kg): 4.20 ∅ internal (cm): 12.0 The dimensions and weights are provided as a guideline. The compliance verification parameters for the certification requirements comply with the compatibility procedures for the corresponding roof tile accessories. Tejas Cobert recommends on-site...

Open the catalog to page 4
Cobert Delta - 5

technical specifications Type: Double lap, double interlocking Straight bond Suitable tile for installation on mixed-profile panel (under tile). The figures in this document are nominal and comply with regulatory tolerances. 1 mm = 0.03937 inches - 1 square metre = 10.764 square feet - 1 kg = 2.2046 lbs. Tejas Cobert reserves the right to change the dimensions, weights and units per pallet of its products without prior notice. For further information, check the updated technical features in www.tejascobert.com or contact Customer Support Service. MAXIMUM IMPERMEABILITY HIGHEST BREAKING...

Open the catalog to page 5
Cobert Delta - 6

technical information For questions related to local regulations, please contact your distributor. Areas of application Taking into account the altitude, the force of the prevailing winds, rainfall rates and frequency of storms, three basic climatic zones can be considered: Zone 1: interior areas with levels lower than 200 m altitude. Zone 2: interior areas with levels up to 500 m altitude and sea bordering areas. Zone 3: mountain and high mountain areas, as well as ocean-bordering areas. Besides these three areas, it should be considered the climatological effects which may result from the...

Open the catalog to page 6

All Cobert catalogs and technical brochures

  1. GAMA MIXTA

    44 Pages

  2. GAMA LOGICA

    40 Pages

  3. GAMA KLINKER

    20 Pages

  4. Lógica Lusa

    6 Pages

  5. Klinker K2

    6 Pages

  6. Logica onda

    6 Pages

  7. cazorla

    6 Pages

  8. Logica plana

    6 Pages

  9. MIXTA range

    2 Pages

  10. Catalogue 2012

    28 Pages