Rooftop
20Pages

{{requestButtons}}

Catalog excerpts

Rooftop - 1

PACKAGED SOLUTIONS FOR COMMERCIAL APPLICATIONS Inspiring Solutions since 1989

Open the catalog to page 1
Rooftop - 2

Convert your energy expenses into Profit Multiplex cinemas Shopping Centres Production areas Convention rooms Over 20 years of experience with thousands of installed solutions For over 20 years, Clivet has been offering specialized rooftop heat pump solutions for air conditioning and air renewal in medium and high attendance areas such as multiplex cinemas, hypermarkets, shopping centres, theaters, congress rooms, restaurants and performance venues. In these applications where optimum temperature and humidity, air purification and correct ventilation are essential for the comfort of...

Open the catalog to page 2
Rooftop - 3

Rooftop: heat pump packaged units With Clivet rooftop units, comfort and air quality are guaranteed with a single product. Being packaged units, all plant components are inside the unit, already assembled and tested. The necessary thermal or cooling energy is produced only where and when it is needed, for this reason they can be installed autonomously near the area to be air-conditioned with plant savings. The Installation and maintenance operations are simple and quick. YOUR INVESTMENT INCREASES THE BUILDING VALUE A high-tech solution, designed for each specific application and built on an...

Open the catalog to page 3
Rooftop - 4

Technology THERMODYNAMIC RECOVERY OF ENERGY FROM STALE AIR The energy contained in the air exhausted from the internal environments is not simply exhausted, but conveyed and recovered by the external finned coil exchanger (CCK version). The maximum level of recovery efficiency is obtained through THOR Thermodynamic Recovery (THermodynamic Overboost Recovery), consisting of a dedicated exchanger integrated in the cooling circuit (CCKP version). FREE COOLING free cooling As soon as the external conditions allow, the unit is able to automatically activate the FREE-COOLING mode, which cools the...

Open the catalog to page 4
Rooftop - 5

Comfort and air quality in one product The electric Heat pump technology promotes and provides incentives by the European Union with specific standards, such as the EU Directive 2009/28/CE of April 23rd 2009 that recognises ambient heat as a renewable source. Compared to a combustion system, the electric heat Pump allows: ✓ energy saving and reduction of the CO2 emissions by an average Renewable Energy fossil fuels CO2 emissions particulates other harmful substances resulting from combustion ✓ use of electric energy, increasingly produced through alternative and renewable sources ✓...

Open the catalog to page 5
Rooftop - 6

Reduction of consumption and noise emissions in the external section are guaranteed thanks to the continuous modulation of the rotation speed according to the punctual operating conditions of the refrigeration circuit. Internal components arranged by type in homogeneous areas that are easy and safe to access thanks to the hinges with adjustable locking closures. Device that locks the access panel to the electrical panel and protects the operator in case of rain. AUTOMATIC OPERATION The graphical interface designed for wall installation automatically manages the operation of the unit and...

Open the catalog to page 6
Rooftop - 7

AUTOMATIC AIRFLOW MANAGEMENT ✓ STANDARD - Constant supply airflow in all conditions ✓ ECO - The supply airflow is kept constant as the thermal load changes, stopping instead when the load is satisfied. Manual or automatic activation with Clivet Supervision System. ✓ VARIABLE AIRFLOW - The supply airflow varies according to the thermal load up to a minimum value compatible with the chosen air distribution and diffusion system. Ventilation active even if the load is satisfied. ACOUSTIC AND THERMAL INSULATION Sandwich paneling consists of a double steel wall that encloses the insulating...

Open the catalog to page 7
Rooftop - 8

Medium attendance ✓ offices ✓ shops ✓ supermarkets ✓ hypermarkets ✓ shopping centers ✓ production areas SMARTPack2 CKN-XHE2i load Intensity contemporaneity of loads High attendance ✓ cinemas ✓ theaters ✓ conference rooms load Intensity contemporaneity of loads ✓ kitchens ✓ smoking rooms load Intensity contemporaneity of loads need for renewal air

Open the catalog to page 8
Rooftop - 9

CAK - Single fan section for full recirculation For air conditioning applications only, without the need for air renewal. The supply fan section provides the required supply and return available static pressure. CBK - Single fan section for recirculation and fresh air For applications where you need to keep the room in over-pressure, with the option of controlling a particular fresh air flow. The supply fan section provides the required supply and return available static pressure. CCK - Double fan section for recirculation, fresh air, exhaust, thermodynamic recovery For applications with...

Open the catalog to page 9
Rooftop - 10

Why Clivet? ENERGY SAVING Devices developed to intelligently manage energy and their coordination according to environmental conditions. They allow: reduction of operating costs, maximum use of renewable energy, reduction of environmental impact, increase in the value of the property. PROFESSIONAL INSTALLATION Clivet entrusts the proposal of its products to specialized professionals. Clivet certified technicians carry out the first start-up of the installed unit, checking its correct installation and optimal operation. WARRANTY EXTENSION Clivet offers the possibility to extend the warranty...

Open the catalog to page 10
Rooftop - 11

Revamping of existing systems Following the Covid-19 emergency and in accordance with the provisions of the Italian Institutions and Assoclima, Clivet suggests keeping the air conditioning systems in operation after careful cleaning and maintenance. In addition, to improve the air quality in buildings served by existing systems, he has developed a turnkey kit for replacing filters with electronic ones on already installed Clivet units. DESIGN ACCORDING TO CONSOLIDATED STANDARDS System components are created for the specific application. They can therefore be selected immediately for each...

Open the catalog to page 11
Rooftop - 12

IL CENTRO Shopping Center Arese, Milan, Italy GLA: 93.000 m2 Systems: WLHP, Packaged Year 2017 Centro Porsche Padova Padua, Italy Systems: Packaged, Split Year 2020 Rogoza Sport Center Rogoza, Slovenia System: Packaged Year 2020 Esmoriz Supermarket Esmoriz, Porto, Portugal System: Packaged (CLIVETPack2) Year 2020 EDUCATION RETAIL RETAIL HD4 Sport Hall Mountain Divcibare, Serbia System: Packaged Year 2020 Fakulty of ISLAM Sarajevo, Bosnia and Herzegovina System: Packaged (SMARTPack2) Year 2020

Open the catalog to page 12

All Clivet S.p.A catalogs and technical brochures

  1. WCH- i

    2 Pages

  2. WSAT-YSC4

    4 Pages

  3. WSAN-YSi

    2 Pages

  4. CLIVET EYE

    4 Pages

  5. Air is life

    8 Pages

  6. SPLIT systems

    121 Pages