video corpo cad

Synops
1Pages

{{requestButtons}}

Catalog excerpts

Synops - 1

TECHNICAL DATA SHEET ETA certified partition GEOMETRICAL FEATURES Relocatable steel or glazed monoblock partition. • DIMENSIONS: .. Height: monoblock up to 3600 mm. .. idth: up to 1600 mm for solid panels, W above for glazed panels. .. Weight: 25 kg/m2 • REACTION TO FIRE: . Euroclass following EN 13501-1: A2-s1,d0 CONSTRUCTION • MONOBLOCK ELEMENTS: .. prights: steel sections, 1.2 mm thick. U .. Thickness: 83 mm. .. kins: steel, 1 mm thickness with S reinforcements welded to the inner surface. .. Internal filler: mineral wool. .. loor and ceiling channels: steel F profiles. • LAZED PANELS: G .. ingle and double glazing: extruded aluS minium frame sections, glazing beads or flush bonded glass. .. ll the elements are fully pre-fabricated A and are delivered as finished products to site. • DOOR PANELS: .. Metal frame 1.2 mm thick. .. Leaf: steel, glass or timber, with adjustable base drop seal. Optional: solid leaf or flush glazed on both sides, 83 mm thick. • jUnction : 6 mm wide. Vinyl or steel seal. FiniSHeS AND OPTIONS • URFACE TREATMENT: S After surface treatment by alkaline degreasing and nanoceramic conversion of the skins and accessories, application of thermosetting polyester powder paint, ovencured at 180°C (thickness 70 ± 10 µm). The paint gives a decorative surface that is shock and UV resistant. InStallation features • tolerances: .. floor: ± 20 mm .. ceiling: ± 15 mm • connection of panel types: The panels interlock using a steel headed cam. • NTEGRATION OF ELECTRICAL AND DATA I SERVICES: .. he top and bottom channels allow the T horizontal passage for electric wiring through the partition. .. ervice panel with removable skins S allows the installation and integration of electric switches and power sockets. AcoustiCS Weighted sound reduction index following EN ISO 717-1 • OLID PANEL: S from Rw (C ; Ctr) = 47 (-4 ; -11) dB to Rw (C ; Ctr) = 52 (-2 ; -5) dB .. ith solid door: w Rw (C ; Ctr) = 43 (-3 ; -9) dB • ull height double glazed PANEL F pane upgraded to acoustic laminate: .. ith 1 pane upgraded to acoustic w laminate glass: Rw (C ; Ctr) = 45 (-2 ; -8) dB .. ith solid door: w Rw (C ; Ctr) = 43 (-3 ; -9) dB • IRE RESISTANCE: F Dependant on design characteristics up to: .. Solid panel: EI 90 .. Glazed panel: EI 60 .. Door: EI 30 in accordance with European tests and equivalent BS standards. Dimension limits in accordance with certificate. CLEANING The thermo-hardened epoxy polyester powder paint finish of the partitions means they can be cleaned easily by using a rubber squeegee and a mild detergent. ACCESSORIES Clestra offers a wide range of partition accessories, provided with clever selffastening systems. Coat hooks, hooks, picture rails, whiteboards, door signs, document holders, can be put up and taken down like a «post-it®», without damaging the partition. Magnetic, suction or velcro fastening depending on the supporting partition. www.hop-hop.com Our products are constantly changing. To find out about the latest approved acoustic performances, please visit www.clestra.com. • coloURs: Colours in Clestra colour chart. Others: following technical approval. The information in this brochure is given for guidance only - 2012 • ACKING SYSTEMS: R Solid panel vertical junctions can accommodate a concealed racking upright that facilitates the support of furniture items such as shelving, storage units and desking. The upright can be retrofitted and relocated if required. • optionAL: THE INSERT-PANEL: The insert panel design option allows various finishes to be installed into the wall face. The panel finish can be of steel painted/perforated, timber, fabric or leather and sits within a preformed recess. The unit is of variable height and modular width and will maintain the partition’s flush appearance. • GLAZING: Film, sand blasting, stained glass.

Open the catalog to page 1

All Clestra catalogs and technical brochures

  1. BAYA

    8 Pages

  2. FIRE

    6 Pages

  3. POD_UK_2017

    2 Pages

  4. Synchrone

    1 Pages