Gree"~r Top energy-efficient heating & cooling fan coil technology for low-temperature systems
Open the catalog to page 1Cool Comfort: A constant flow of eco-friendly cool air (refrigerant-free) for a draft-free comfort and cooling sensation.
Open the catalog to page 3Warm Comfort : The Greenor® fan coil saves energy while optimizing low-temperature heating systems (water at 50°C/ 122°F) operating with heat pumps using renewable energy or condensing boilers. Its unique concept offers comfort, high-end design and top-efficiency.
Open the catalog to page 4DOCK GRANIT
Open the catalog to page 5A one-off custom made piece to dress-up your interior …
Open the catalog to page 7Greenor®, a product engineered for low-temperature systems able to operate with different heating systems: conventional boiler, heat pump, chiller, or solar and geothermal energy. Key benefits: ■ Technology and Quality Driven by their passion for excellence in technology and in design, Ateliers Cinier have dedicated two full years in R&D to conceive and create a trend-setting and innovative product meeting today’s environmental requirements in terms of energy efficiency and using renewable energy for the highest quality in indoor heating and cooling. The direct result is the launch of the...
Open the catalog to page 9Infrared picture «Warm » Infrared picture «Cold» Infrared Fluke camera showing the Incoming water Infrared Fluke camera showing the Incoming water An innovative way to distribute heat: The diffused flow of warm air is distributed over a perimeter of 16,1 Ft / 492 cm. A warm radiant front panel in Olycale® stone allows greater comfort and higher energy-efficiency. Horizontal distribution of the even-flow substantially reduces the vertical temperature difference between the floor and ceiling unlike what is observed with standard convection systems. It creates nearly no dust movement and no...
Open the catalog to page 10■ 11,5cm / 4-1/2'' thick : the slimmest fan coil on the market. ■ Optimal energy-efficient solution for low temperature systems using renewable energy (heat pumps, condensing boilers, chillers) ■ Horizontal draft-free and diffused even flow of warm or cool air distributed over a 492 cm perimeter/16.1 feet. No sensation of draft. ■ A radiant front panel in Olycale® stone for greater comfort and higher energy-efficiency ■ 3 operating speeds ■ International patent # PCT/FR2010/00321 ■ Ideal for large areas ■ Reversible fan coil for total comfort all year around ■ Energy consumption divided by...
Open the catalog to page 12TITANE BRONZE
Open the catalog to page 13Applications: To replace hydronic radiators or fan coil systems New installations Residential & Commercial Applications: Single family homes Apartments Restaurants, boutiques, hotels Lobbies Offices ... and where architecture wants to meet energy efficiency, comfort and modern design aesthetic. Greenor® is available as a reversible heating and cooling system or as a heating system only. ■ The infrared remote control: easy to use Choose your operating speed Choose your room temperature set point Program your ideal room temperature ■ Hand/hard-wired control panel: easy heating and cooling...
Open the catalog to page 14UNIS by Michel Cinier Simplicity and minimalism. Also Quartz and Olycale White finish. Other GRIS QUARTZ
Open the catalog to page 15Pure and minimalist, the hand-finished blue waves dance between sky and sea on an ocean blue background. The brown ochre symbolizes the clay of the earth. Greenor Greenor OCRE BRUN RATINE BLEU PATINE
Open the catalog to page 16SCULPTURAL Architectural sensitivity. Sculptural and dressed in red, contemporary design by Michel Cinier. Also available in Olycale white and other finishes upon request. JEUX D'OMBRES Games of Shadows. Where light and shade play games. Greenor SCULPTURAL Greenor JEUX D'OMBRES GRIS QUARTZ 18
Open the catalog to page 17ECUME A minimalist design for this very contemporary piece where the purest lines are hand-drawn directly on the stone. We recommend renderings in white Olycale stone or in slate gray. ORIGINE Making sense of the raw material, echo of a vision of the world as felt by the artist. Greenor ECUMEBLANC OLYCALE GreenorORIGINE IVOIRE
Open the catalog to page 18ONE-OFF COLLECTION by Johanne Cinier Each one-off piece is created by artist Johanne Cinier. Upon special order and together with the artist, you can create your own personalized Greenor. CHEYENNE With Cheyenne traditions, this one-off design is organized in a series of rhythmical and deep blue with accents of powerful greens, symbol of the prairie, home to the Cheyenne. AMADHY This tinted garden of serenity, Amadhy, elements bursting like a thirst-quenching spring.
Open the catalog to page 19Mineral Inspiration Using an overlay of bright and deep reds with a white finish patina that reflects a gray sheen, Dock Granit portrays the marriage of the post industrial era with the world of minerals. Greenor Greenor
Open the catalog to page 20ONE-OFF COLLECTION by Johanne Cinier voltage colors in this very New-York graffiti-inspired creation. BARCELONA Powerful colors challenge, physical courage, strength mental energy.
Open the catalog to page 21HAWAII Floral, invigorating. ROSEGREY Inspiration, substance, creation. Greenor Greenor
Open the catalog to page 22TITANE by Johanne Cinier TITANE SILVER TITANE BRONZE 2 exceptional pieces. Fusion and matter for a unique metal finish. TITANE SILVER
Open the catalog to page 23TITANE BRONZE
Open the catalog to page 24Energy output Heat mode W/ Btu/h Energy output Cool mode W/ Btu/h Load loss factor (kpa) Energy output Heat mode W/ Btu/h Energy output Cool mode W/ Btu/h Load loss factor (kpa) Sound Sound power Required water flow: 1.28 GPM Power supply: 120 V - 60 Hz for the US and Canada markets. 220 V - 50Hz for the others markets. Performance tested under the following conditions: A* : Heat mode : room temperature 20°C-68°F) inlet water temperature 70°C-158°F - delta T water 10°C-50°F A* : Cooling mode : room temperature 27°C-80.6°F, inlet water temperature 7°C-44.6°F - delta T water 5°C-41°F B** :...
Open the catalog to page 25Energy output Load loss Heat mode factor (kpa) Energy output Load loss Heat mode factor (kpa) Required water flow: 1.28 GPM Power supply: 120 V - 60 Hz for the US and Canada markets. 220 V - 50Hz for the others markets. Performance tested under the following conditions: A* : Heat mode : room temperature 20°C-68°F, inlet water temperature 75°C-167°F - delta T water 10°C-50°F B* : Heat mode : room temperature 20°C-68°F, inlet water temperature 55°C-131°F Air flow sound level measured using a reverberating room at a distance of 1m - 39'' from the device. Energy performances and technical data...
Open the catalog to page 26All CINIER catalogs and technical brochures
-
Belle Epoque
32 Pages
-
2021 CINIER LOOKBOOK
112 Pages
-
Cinier News 2021
20 Pages
-
LUMINAIRES LED - LED LIGHTING
44 Pages
-
ORIGINE
2 Pages
-
SCULPTURAL
4 Pages
-
Seche-serviettes Yacht
2 Pages
-
Cascade -3
2 Pages
-
Catalogue 2018
180 Pages
-
New CINIER Design 2013
7 Pages
-
CINIER luminaires collection LT
16 Pages
-
press release 2013
7 Pages