The new H type CINQUECENTO series Low NOx burners Class 3 (< 80 mg/kWh), made in aluminum housing with a backward curved centrifugal impeller is studied and developed to get high performance and efficiency combined with low emissions. In this manner these series can burn the two flues separately. This is possible because these burners are equipped with an independent electric motor for the activation of the oil pump. As a consequence during gas firing, the oil pump motor does not operate and remains off. These burners are equipped with a high performance combustion head, designed to achieve an high irradiating flame when they run on natural gas. Instead, when they run on light oil, they are equipped with a by-pass nozzle which, using a pressure regulator, can reach a modulating ratio of 1:3. Therefore, the burners are provided with an UV photocell to control the flame during the operation. H365X PR-MD...xR H440X PR-MD...xR H500X PR-MD...xR Back-pressure in combustion chamber (mbar)
Open the catalog to page 1TECHNICAL DETAILS Type Gas connections Noise level Auxiliary electrical Motor electrical Fan motor Pump motor power supply power supply max. kW Rp dBA kW 3.650 230 V 1N AC 50 Hz 400 V 3 AC 50 Hz 7,5 1,1 2” - DN65 - DN80 - DN100 < 85 9,2 1,5 2” - DN65 - DN80 - DN100 < 85 4.400 230 V 1N AC 50 Hz 400 V 3 AC 50 Hz 9,2 1,5 2” - DN65 - DN80 - DN100 < 85 5.250 230 V 1N AC 50 Hz 400 V 3 AC 50 Hz For the configuration of the gas train, see pages 116-117. Suggested boiler drilling Burner flange Approximate values (regarding model with gas train DN 80) Approximate values
Open the catalog to page 2Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar) Back-pressure in combustion chamber (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Minimum inlet gas pressure (mbar) Attention: the graph shows the value of the gas output (kW) against the corresponding pressure without the combustion chamber back pressure. To know the minimum gas pressure at gas train, in order to get the gas output, it is necessary to add the boiler back pressure to the value read on the curve.
Open the catalog to page 3All CIB UNIGAS S.p.A. catalogs and technical brochures
-
Burners for Industrial Applications
252 Pages
-
Medium small burners
204 Pages
-
Medium large burners
324 Pages
-
Catalogue Professional 2022
332 Pages
-
Catalogue Residential 2022
224 Pages
-
Catalogue Residential 2020
216 Pages
-
681 NOVANTA [kW 470 ÷ 3.100]
3 Pages
-
629 NOVANTA [KW 440 ÷ 3.100]
3 Pages
-
195 MINIFLAM [kW 29 ÷ 209]
1 Pages
-
172 IDEA [kW 70 ÷ 560]
3 Pages
-
39 IDEA [kW 19 ÷ 85]
4 Pages
-
315 IDEA [kW 65 ÷ 570]
4 Pages
-
307 IDEA [kW 35 ÷ 200]
4 Pages
-
TECNOPRESS [kW 160 ÷ 2300]
2 Pages
-
IDEA 35 / 60-70-90 / 120-140-200
16 Pages
-
2011 Catalogue
194 Pages